A study of multicavity concept applied to hexagonal coaxial haloscopes
J.M. García-Barceló, Jose R. Navarro-Madrid, and Alejandro Díaz-Morcillo · 2026
Read A study of multicavity concept applied to hexagonal coaxial haloscopes by J.M. García-Barceló, Jose R. Navarro-Madrid, and Alejandro Díaz-Morcillo (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-08932.txt.
Introduction
J. García-Barceló, Jose Navarro-Madrid, and Alejandro Díaz-Morcillo design bigger hunting chambers for axions, the hypothetical dark matter particles, using hexagonal coaxial cavities tuned near thirty gigahertz. A haloscope's reach grows with sensitive volume, but magnet bores are tight. Moving from one cavity to dual and triple subcavity layouts, they tune resonance by rotating inner hexagonal prisms while preserving strong quality and form factors.
The triple design triples performance over the single cavity baseline. A four subcavity version fits the strict radial limit in theory if wall thicknesses are optimized for frequency stability. Mode splitting, manufacturing tolerance, and heat remain practical hurdles. Dark matter searches gain a scalable one port route into high frequency territory.
Catalog record
| CREATOR | J.M. García-Barceló, Jose R. Navarro-Madrid, and Alejandro Díaz-Morcillo |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 31 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.08932
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A study of multicavity concept applied to hexagonal coaxial haloscopes J.M. García-Barceló, Jose R. Navarro-Madrid, and Alejandro Díaz-Morcillo Abstract In this work, a study on the development of scalable multicavity architectures for axion haloscopes, based on a hexagonal coaxial geometry operating at 30 30 GHz frequencies, is presented. To enhance the scanning rate and sensitivity within the limited volume of experimental magnet bores, the transition from a baseline single-cavity design to dual and triple-subcavity configurations is investigated. A novel tuning mechanism based on the rotation of one or two inner hexagonal prisms is implemented, providing a robust method to shift the resonant frequency while maintaining high form and quality factors. The results show that the triple-subcavity design achieves an improvement of × 3 \times 3 over the single-cavity baseline. The scaling potential of quad-subcavity architectures under a strict radial constraint of 25 25 mm is further explored. Theoretical analysis confirms that a four-subcavity system is feasible within a certain radial clearance, provided that wall thicknesses are strategically optimised to ensure frequency stability. The practical challenges associated with mode splitting, manufacturing tolerances, and thermal management in these high-order systems are also discussed. This one-port multicavity approach offers a viable path toward increasing the sensitive volume of haloscopes, enabling more efficient exploration of the axion dark matter parameter space in high-frequency regimes. 1 Introduction Axions are hypothetical pseudo-Goldstone particles that were proposed by Weinberg 32 and Wilzcek 33 as a solution to the strong-CP problem in Quantum Chromodynamics (QCD) 25 ; 24 and whose expected characteristics make this particle difficult to detect, since it would be extremely light, neutral and are predicted to interact only minimally with ordinary matter and electromagnetic (EM) fields. These characteristics make them also great candidates to be part of Dark Matter (DM). Recently, there has been a significant rise in the number of experiments and methods aimed at either identifying or ruling out axions as DM (see, for example, 14 ). An axion haloscope is a type of experimental device designed to detect DM axions, and whose aim is to detect these particles by converting them into observable EM signals (i.e., photons) through the inverse Primakoff effect in the presence of a strong magnetic field 27 . To enhance this conversion method, axion haloscopes employ resonators with high quality factors, such as microwave cavities 29 . The conversion from these particles to photons occurs when the axion mass closely aligns with the resonant frequency of the detector. Since the mass of the axion is unknown, and it is directly related to the generated photons frequency ( f\approx m_{a}c^{2}/h ), different kinds of haloscopes have been designed in order to cover distinct frequency ranges. Currently, notable examples of haloscope experiments are ADMX (Axion Dark Matter eXperiment) 31 and CAPP (Center for Axion and Precision Physics) 34 , which operate below and above 1 GHz, respectively. The ADMX collaboration has reached significant sensitivities in the 2.81-3.31 \mu eV range 5 , while CAPP has proposed a DFSZ-sensitive haloscope exploring the 4.51 to 4.59 \mu eV range 34 . The HAYSTAC team has achieved KSVZ-sensitive results in the 16.96-17.28 \mu eV and 23.15-24.0 \mu eV mass ranges 36 ; 4 . Other groups, such as RADES 21 ; 1 (which this study is part of), and QUAX 3 ; 2 have also made notable advances in haloscope technology. The main objectives of an efficient axion detection system are to maximise the power produced by the axion-photon interaction and to broaden the spectrum of axion masses being probed (i.e., the range of scanned frequencies). The detected radiofrequency (RF) power ( P_{d} ) depends on the intrinsic properties of the axion and the experimental cavity detector, as described in 8 (in natural units): P_{d}=\kappa g_{a\gamma}^{2}\frac{\rho_{a}}{m_{a}}B_{e}^{2}CVQ_{l}, (1) where \kappa is the external receiver coupling (which is commonly re-expressed in terms of the coupling coefficient \beta=\frac{\kappa}{1-\kappa} ), g_{a\gamma} the axion-photon coupling, \rho_{a} the DM density, m_{a} the mass of the axion, B_{e} the external static magnetic field, C the form factor, V the volume of the cavity, and Q_{l} its loaded quality factor. To have critical coupling, \kappa=0.5 is needed. In contrast to the loaded quality factor, the unloaded quality factor ( Q_{0} ) is a widely used parameter for characterising resonant cavities, as it does not depend on input/output couplings ( \kappa ) 26 ; 28 . The form factor C quantifies the alignment between the external magnetostatic field of the employed magnet ( \vec{B}_{e} ) and the electric field generated by the axion field after the conversion to photons in the cavity ( \vec{E} ), and it is defined as C\,=\,\frac{|\int_{V}\,\vec{E}\cdot\vec{B}_{e}\,dV|^{2}}{\int_{V}\,|\vec{B}_{e}|^{2}\,dV\int_{V}\,\varepsilon_{r}\,|\vec{E}|^{2}\,dV}, (2) where, \varepsilon_{r} is the relative electrical permittivity in the cavity. The magnetic field B_{e} will depend on the magnet used for the axion search, which will also limit the experimental space and, thus, the maximum dimensions of the resonant cavity. The magnets most commonly used in haloscope experiments are of solenoid type, whose bore section is circular, making the cylindrical shape the most efficient geometry for designing the resonant cavities. However, there are cases where dipole magnets are used, so a rectangular cavity can also be efficient. To increase the likelihood of detecting axions, the haloscope must be tuned to the resonant frequency corresponding to the expected axion mass range under investigation. Consequently, the scanning rate ( \frac{dm_{a}}{dt} ) is defined as the speed at which a mass range can be scanned at a given sensitivity g_{a\gamma} 17 , and is commonly used to extract the haloscope Figure of Merit (FoM) that takes into account the cavity design parameters: \text{FoM}=Q_{0}V^{2}C^{2}. (3) From equation 2 , it can be extracted that the more parallel the electric field of the resonant mode excited (by the axion field) in the cavity is to the magnetic field of the magnet, the higher the form factor will be. For a solenoid magnet, this is the case of the \mathrm{TM_{010}} mode, which is most commonly used in haloscope experiments. The diameter of the cylindrical cavity determines the resonant frequency of this mode, and consequently, the axion mass range to which the experiment is most sensitive, and probing higher axion masses (that is, higher frequencies) typically requires smaller diameters. However, reducing the cavity size leads to a decrease in the signal power and the scanning rate, as the former scales as Q_{0}V (see eq. 1 ) and the latter as Q_{0}V^{2} (see eq. 3 ). As a result, in recent years, new techniques have been investigated to explore the high-mass region. One of the techniques consists of employing multicavity structures, as in RADES 23 ; 22 and CAPP 15 ; 35 , which provides promising results for high-frequency haloscope volume enhancement. This technique enables having multicavities in more than one dimension, both in rectangular and cylindrical geometries (see 10 and 11 , respectively). Also, the use of dielectric cavities 6 , multirod cavities 30 , wire metamaterial cavities (or plasma haloscopes) 20 , or the multiple-cell structure 16 are examples of other techniques that deal with the problem of frequency scaling. The main disadvantage of the multicavity technique lies in the difficulty of applying mechanical tuning systems in them due to the number of partitions and the