Robust Capacity Expansion under Wildfire Ignition Risk and High Renewable Penetration DOI: 10.1145/3744255.3811725 Conference: The 17th ACM International Conference on Future and Sustainable Energy Systems; June 22–25, 2026; Banff, AB, Canada The 17th ACM International Conference on Future and Sustainable Energy Systems (E-Energy ’26), June 22–25, 2026, Banff, AB, Canada ISBN: 979-8-4007-2011-6/2026/06 CCS: Applied computing Multi-criterion optimization and decision-making CCS: Hardware Renewable energy
Tomás Tapia, Ryan Piansky, Yury Dvorkin, Jean-Paul Watson · 2026
Read Robust Capacity Expansion under Wildfire Ignition Risk and High Renewable Penetration DOI: 10.1145/3744255.3811725 Conference: The 17th ACM International Conference on Future and Sustainable Energy Systems; June 22–25, 2026; Banff, AB, Canada The 17th ACM International Conference on Future and Sustainable Energy Systems (E-Energy ’26), June 22–25, 2026, Banff, AB, Canada ISBN: 979-8-4007-2011-6/2026/06 CCS: Applied computing Multi-criterion optimization and decision-making CCS: Hardware Renewable energy by Tomás Tapia, Ryan Piansky, Yury Dvorkin, Jean-Paul Watson (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-07880.txt.
Introduction
Tomás Tapia and three co-authors plan power grid investments against two worst cases at once. One is wildfire ignition risk that forces lines to be de-energized; the other is the variability of renewable generation. Shutting lines down is a standard fire prevention move, but it interacts badly with wind and solar swings. Batteries and undergrounded lines can soften both problems.
Their robust optimization model chooses where to place storage and which lines to bury, using representative weeks and uncertainty sets that respect how the uncertain quantities move together over time. Formulated as a mixed-integer program and solved with a column-and-constraint generation algorithm, the framework was tested on a model of the San Diego power system. There it improved resilience to wildfire-driven de-energization.
Catalog record
| CREATOR | Tomás Tapia, Ryan Piansky, Yury Dvorkin, Jean-Paul Watson |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 51 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.07880
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Robust Capacity Expansion under Wildfire Ignition Risk and High Renewable Penetration DOI: 10.1145/3744255.3811725 Conference: The 17th ACM International Conference on Future and Sustainable Energy Systems; June 22–25, 2026; Banff, AB, Canada The 17th ACM International Conference on Future and Sustainable Energy Systems (E-Energy ’26), June 22–25, 2026, Banff, AB, Canada ISBN: 979-8-4007-2011-6/2026/06 CCS: Applied computing Multi-criterion optimization and decision-making CCS: Hardware Renewable energy Tomás Tapia, Ryan Piansky, Yury Dvorkin, Jean-Paul Watson Abstract . In power systems, the risk of wildfire ignition has increased significantly in recent years. The impact and severity of these events on energy dispatch, as well as their societal ramifications, make wildfire prevention critical for power system planning and operation. A common intervention by system operators is to de-energize transmission lines to mitigate the risk of fire caused by equipment failures. With the growing integration of variable renewable generation, managing and preparing the system to de-energization under wildfire risk has become even more challenging. In this context, mitigation decisions such as installing battery energy storage systems and undergrounding transmission lines can reduce the risk and adverse effects associated with de-energization and renewable generation variability. This paper presents a robust optimization model to determine the optimal location of battery storage and undergrounding of transmission line investment, utilizing representative weeks and uncertainty sets to capture the temporal relationship of uncertain variables. Specifically, this paper addresses: (i) the worst-case realization of ignition risk leading to the de-energization of transmission lines, combined with the worst-case realization of renewable energy availability, and (ii) the optimal investment decisions for energy storage capacity and undergrounding of transmission lines that are exposed to ignition risk. The proposed model is formulated as a mixed-integer linear programming (MILP) problem, employing duality theory and binary decomposition to address nonlinearities, and is solved using a column-and-constraint generation algorithm. The proposed framework is evaluated on a model of the San Diego power system, demonstrating its practical effectiveness in improving the resilience to wildfire risk. † † cc-license: by 1. Introduction 1.1. Motivation and Scope Due to the continued evolution of power systems, capacity expansion planning (CEP) is a key process for governmental energy commissions and utilities to ensure resource adequacy, reliability, and cost-efficient energy supply. In many jurisdictions, CEP is also mandated by law as part of regulatory compliance. CEP finds the least-cost mix of new investments in generation, storage, and transmission infrastructure of a power system over a given planning horizon, based on an estimate of future system requirements such as demand growth, renewable integration targets, reliability standards, and policy constraints. With the increasing integration of variable sources and the growing occurrence of of weather-driven events, this process has become challenging due to the significant levels and sources of uncertainty introduced to the system ( 11 ) . Several states, including California, Texas, and New York, are increasingly adopting modeling approaches to explicitly account for these uncertainties in their long-term planning processes. Underestimating power system variability factors, such as fluctuating renewable generation and load demand, generator outages, fuel supply disruptions, transmission constraints, and extreme weather events, can lead to significant contingencies that disrupt normal grid operations, potentially resulting in component disconnections and compromising the security of power supply. Given this, developing efficient tools that capture and cope with the inherent uncertainty has become a critical task for energy planners. In this context, wildfires represent a major threat to the secure operation of power systems. During recent years, California, Canada, Australia, Portugal, and Chile have suffered from wildfires that have lead to supply interruption ( 18 ) . The treatment of wildfire events in power systems has been approached in different directions: (i) wildfire mitigation, focused on the pre-disaster stage that considers all forecasting and infrastructure investment; (ii) wildfire response, focused on emergency response actions; and (iii) disaster restoration, focused on infrastructure repair and energy rehabilitation strategies. Furthermore, as the adoption of variable renewable energy sources grows, strengthening their resilience to wildfires becomes more challenging due to the increased uncertainty these systems face. Unlike dispatchable fossil plants, wind and solar plants rely on weather and long lines, so wildfire smoke, heat, and line outages can simultaneously cut production and access, reducing resilience. In the first direction, wildfires caused by the infrastructure of the power system (e.g. sparks, faults, etc.) are not atypical due to aging components and severe climate conditions that increase the potential failure, ignition, and fire spread ( 12 ) . To mitigate this threat, utilities can temporarily turn off power or de-energize specific areas under high wildfire ignition risk to prevent infrastructure-related wildfire ignitions, the so-called Public Safety Power Shutoff (PSPS) events ( 5 ) . Consequently, system operators must carefully balance operating costs, manage component de-energization, and reduce wildfire ignition risk. In this context, accurately quantifying wildfire ignition risk can support more informed and effective component de-energization planning, particularly for transmission lines. With ignition risk map information, system operators can better anticipate periods and locations of elevated wildfire risk and estimate periods where transmission lines will be de-energized to avoid operations during times of high ignition threat. Integrating this temporal risk information into CEP offers an opportunity to co-optimize both wildfire mitigation measures, such as preemptive transmission de-energization, and power system investments. This paper uses robust optimization to consider the uncertainty sets for wildfire ignition risk and renewable energy variability in CEP, ensuring that the investment takes into account the variability between ignition risk and variable generation availability forecasts under an uncertainty budget, potentially reducing the probability of catastrophic events while maintaining reliable power delivery. The resulting model is a mixed-integer linear program (MILP) that captures both the discrete nature of investment, operational decisions, and inter-temporal constraints. 1.2. Literature review CEP problems have been widely studied due to their significant role in guiding investment and ensuring reliability. In recent years, various approaches have been explored to address uncertainty factors inherent to these problems, including stochastic optimization ( 12 ) , robust optimization ( 23 ; 18 ) , and distributionally robust optimization ( 7 ) . Each of these methodologies employs different techniques to quantify uncertainty arising from variable factors such as weather conditions, renewable resource availability, and energy demand. For example, scenario-based methods ( 11 ; 12 ) , and uncertainty sets ( 23 ; 18 ) , are commonly used to represent possible realizations of these uncertainties. The increasing integration of renewable energy sources into the grid, coupled with the increasing frequency of weather-driven events, has heightened the importance of accurately modeling these uncertainties to assess and enhance system resilience. As power systems continue to evolve towards a larger integration of variable generation energy, ensuring their robustness against weather-driven events becomes an even greater challenge. A key challenge arises when line de-energization due to wildfire risk overlaps with low renewable availability, leading to suboptimal use of storage or investment decisions. CEP must also address supply and demand variability, growing flexibility needs, and the proper timing of mitigation actions. Failing to account for these factors can result in underinvestment or resource shortfalls. Representing wildfire risk and renewable variability helps identify when and where the system is most stressed, enabling more resilient planning. Our model addresses these challenges by incorporating renewable availability and wildfire risk into