MyoKin3X: A Myoelectric Framework for Full-Hand 3D Force Recording
Charlotte Rohleder, Raul C. Sîmpetru, Annika Wünsch, Alessandro Del Vecchio · 2026
Read MyoKin3X: A Myoelectric Framework for Full-Hand 3D Force Recording by Charlotte Rohleder, Raul C. Sîmpetru, Annika Wünsch, Alessandro Del Vecchio (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-27949.txt.
Introduction
Rohleder and colleagues present MyoKin3X, a rig that records three-dimensional forces from all five fingers at once for studies of hand control. Five sensors, in-place cross-calibration and software joining muscle signals to force readings give standardised measures across hand sizes and tasks. Validation shows tiny calibration drift and very low crosstalk between axes, supporting reliable studies of grip, coordination and human-machine interfaces.
Catalog record
| CREATOR | Charlotte Rohleder, Raul C. Sîmpetru, Annika Wünsch, Alessandro Del Vecchio |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 27317 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.27949
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
MyoKin3X: A Myoelectric Framework for Full-Hand 3D Force Recording Charlotte Rohleder, Raul C. Sîmpetru, Annika Wünsch, Alessandro Del Vecchio Abstract Simultaneous multi-directional force measurement across all five digits is essential for studying hand coordination, compensatory forces, and myoelectric control, yet existing systems typically trade off digit coverage, force dimensionality, and anatomical adaptability. Reliable full-hand acquisition remains challenging because multi-axis calibration, hand-size adjustment, and consistent digit-specific force reconstruction are technically demanding. We present MyoKin3X, a customizable full-hand framework for simultaneous 3D force measurement of up to five digits that provides robust and validated force reconstruction. It combines an anatomically versatile structure with five integrated 3D force sensors and a standalone software for synchronized electromyography (intramuscular and surface) and force acquisition. MyoKin3X provides in-place cross-calibration of all five force sensors, single- and multi-digit maximal voluntary contraction recording, and automated coordinate transformation to digit-specific coordinate systems for standardized analysis across subjects and tasks. Calibration validation demonstrates high stability of the axis-specific calibration factors, with a mean coefficient of variation of 0.04 % 0.04\% . The maximum force error was ± 0.06 \pm 0.06 N at 50 N. It also shows effective inter-axis decoupling (crosstalk reduction: 92.71 % 92.71\% mean reduction; residual crosstalk below 0.02 % 0.02\% for most axis pairs) and high predictive accuracy ( R 2 ≥ 0.99 R^{2}\geq 0.99 across all sensors). The software includes four feedback modes: 1D ramps, fatigue protocols, 2D arbitrary target ramps, and 2D exploratory tasks. MyoKin3X therefore enables standardized full-hand force acquisition with validated measurement reliability, flexible protocol control, and real-time visualization for high-fidelity studies of hand motor control, muscle synergies, and rehabilitation-oriented human-machine interfacing. I Introduction The human hand is actuated by more than 30 muscles that enable dexterous force generation across multiple coupled degree of freedoms (DOFs) , making the study of coordinated force production a central challenge in neurophysiology and biomechanics [ 11 ] . Electromyography (EMG) provides direct access to muscle and motor-neuron activity [ 18 , 6 , 4 ] , but linking these neural commands to their mechanical output requires precise and simultaneous force measurements at the digit level. Numerous force measurement systems have been developed to study multi-digit force production, including load-cell-based systems for flexion-extension measurements [ 14 , 5 ] , multi-axis transducers for natural-posture testing [ 13 ] , and dynamometers for isolated finger segments [ 7 , 3 , 15 ] . However, these systems typically trade off digit coverage, force directions, and anatomical adaptability [ 11 ] , because hand-size variability, multi-axis calibration, and accurate force reconstruction is technically demanding. Kapur et al. [ 8 ] showed that digits produce substantial off-axis forces in single- and multi-digit tasks, and that multi-dimensional feedback enhances control by preserving task-relevant information. These requirements extend to rehabilitation-oriented studies of hand motor dimensions [ 17 ] and human-machine interfacing applications requiring simultaneous proportional multi-digit and multi- DOF control [ 16 ] . To address this gap, we introduce MyoKin3X, a versatile and customizable full-hand 3D force-recording framework for simultaneous multi-digit force acquisition with synchronized EMG (Fig. 1 ). It combines five 3-axis force sensors in an anatomically adjustable structure with standalone software for acquisition and analysis. Key features include single- and multi-digit maximal voluntary contraction (MVC) measurement, built-in calibration, automated digit-specific coordinate transformation, and four feedback paradigms. Together, these components provide a standardized methodology for multi-digit force acquisition in motor-control, force synergy, and myoelectric-interfacing studies. Figure 1: Framework Overview. A) 1D ramp feedback showing target and exerted task-related force magnitude (digit component breakdown shown in main setup sub-figure for clarity). B) 1D fatigue feedback showing exerted magnitude as a bar, target as a black dotted line, and acceptable deviation range as two grey lines. C) Drawing of the MyoKin3X setup with the 3D force framework and the visual interface displaying electromyographic signals and force distribution per sensor axes. D) 2D feedback in each digit’s flexion-abduction plane; colored dots show exerted force per digit and colored squares show predefined targets. E) Exploratory 2D flexion-abduction feedback with digit dots and a heatmap of visit counts per bin. II Methods and Materials II-A Specification of the Force Sensing Setup Digit forces are recorded using five custom-mounted three-axis load cells (K3D40 50\text{\,}\mathrm{N} , ME-Meßsysteme GmbH, Hennigsdorf, Germany) with compact dimensions (40 × 40 × 20 \mathrm{mm} ) to facilitate integration into the experimental setup. Each sensor provides a nominal range of \pm 50 N per axis and is connected to a multi-channel strain-gauge amplifier (GSV-1A4, ME-Meßsysteme GmbH), configured to an input sensitivity of 4 mV/V and supplying a bridge excitation voltage of 5 V. Under this configuration, the sensor sensitivity is approximately 18.5 N/V per axis. The conditioned analog signals are acquired through the auxiliary (AUX) inputs of a bioamplifier system (OT Bioelettronica, Torino, Italy), which provide a \pm 5 V input range and 16-bit analog-to-digital conversion. This corresponds to a theoretical digital force resolution of approximately 2.8 mN per least significant bit. Sampling is performed synchronously with the EMG acquisition at 2\text{\,}\mathrm{kHz}10\text{\,}\mathrm{kHz} . Considering the specified sensor and amplifier tolerances, the practical system accuracy is estimated to be on the order of \pm 0.25 to \pm 0.30 N per axis under static loading conditions. The setup can accommodate other sensor models if the output range matches the recording device. The K3D40 sensor was chosen for its high accuracy and sensitivity while maintaining compact dimensions. II-B Configuration of the 3D Force Framework The framework is adjusted to the participant’s hand dimensions and dominance (Fig. 2 ). It is built from aluminum profiles (Nut 8; cross-section: $30\text{\,}\mathrm{mm}$\times$30\text{\,}\mathrm{mm}$ ; lengths: 30\text{\,}\mathrm{cm} and 50\text{\,}\mathrm{cm} ) with custom 3D-printed components and quick-release connections for fast reconfiguration. Profiles, sensors, and wrist/elbow supports can be aligned to the participant’s anatomy, and measuring tapes on the profiles support reproducible setup documentation. To ensure a precise fit up to the distal interphalangeal joint, the appropriate inlet size for each finger is determined by trial fitting. The base inlet can be rotated inside the digit box to facilitate a comfortable insertion angle. The framework is mounted on a height-adjustable table so participants can sit upright with the elbow supported at 90\text{\,}\mathrm{\SIUnitSymbolDegree} . For intramuscular EMG recordings, A/D adapters can be affixed to the proximal profiles, and force sensor connectors can be secured in custom-made holders for transport. Figure 2: Force Framework Setup Overview and Components. A) Top computer-aided design ( CAD ) view with five mounted sensors and two arm-support profiles. B) Front-left CAD view of the force framework with force sensor and intramuscular EMG amplifier holder. C) CAD view of one sensor assembly with digit box and telescopic inlets of different size. D) Close-up CAD view with two digit boxes mounted on different sides of two sensors; each sensor rotates horizontally via the central fixation joint (quick-release levers not shown). E) Schematic of transformation from the sensor coordinate system (purple, manufacturer axes) to the digit-specific system (blue: flexion, abduction, push) aligned with digit’s degrees of freedom. F) Photograph of a right-handed participant in the framework with all digits inserted and arm fixation at wrist and elbow; surface EMG grids cover flexor, extensor, and intrinsic hand muscles. In the top left, close-up of inserted digits. G) Close-up palmar view of the hand with