Multi-wavelength polarisation imaging with inverse designed metasurfaces
Sarah E. Dean*, Neuton Li, Josephine Munro, Benjamin Laudert, Thomas Siefke, Quyet Ngo, Robert Sharp, Dragomir N. Neshev, Falk Eilenberger, Andrey A. Sukhorukov · 2026
Read Multi-wavelength polarisation imaging with inverse designed metasurfaces by Sarah E. Dean*, Neuton Li, Josephine Munro, Benjamin Laudert, Thomas Siefke, Quyet Ngo, Robert Sharp, Dragomir N. Neshev, Falk Eilenberger, Andrey A. Sukhorukov (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-27756.txt.
Introduction
Dean and nine colleagues present a metasurface design that splits a scene into color and polarization measurements in a single shot. Operating at 532 nm and 700 nm, the design proves robust in simulation, matching color and angular bandwidth needs. They build the design by nanopatterning a titanium dioxide film and show polarization reconstruction for both wavelengths with one structure. The compact design suits lightweight drone imaging, from cells to farm surveying.
Catalog record
| CREATOR | Sarah E. Dean*, Neuton Li, Josephine Munro, Benjamin Laudert, Thomas Siefke, Quyet Ngo, Robert Sharp, Dragomir N. Neshev, Falk Eilenberger, Andrey A. Sukhorukov |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 27537 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.27756
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Multi-wavelength polarisation imaging with inverse designed metasurfaces Sarah E. Dean*, Neuton Li, Josephine Munro, Benjamin Laudert, Thomas Siefke, Quyet Ngo, Robert Sharp, Dragomir N. Neshev, Falk Eilenberger, Andrey A. Sukhorukov Abstract Multispectral polarisation imaging has a broad range of applications, from biological cell imaging to agricultural remote surveying. For such applications, especially involving lightweight unmanned aerial vehicles like drones, it is necessary to have compact, single-shot, efficient optical systems. We present a metasurface design that diffractively separates a scene into spectral and polarimetric measurements with a single optical component, operating for 532 nm and 700 nm in a single-shot imaging system. The polarisation imaging performance of the design is shown to be robust to both spectral and angular bandwidths, and multispectral polarimetry is demonstrated experimentally. * Sarah E. Dean, \linkable [email protected] 1 Introduction Polarisation imaging is the process of measuring the orientation of light waves across a scene of interest to gain additional insights beyond what is achievable with intensity imaging. A broad range of applications benefit from the addition of polarisation imaging, including aerosol monitoring [ 36 , 24 , 34 ] , biological cell imaging [ 35 , 20 ] , or agricultural applications where the polarisation response at multiple wavelengths can provide beneficial information for crop identification or vegetation health monitoring [ 25 , 23 , 17 , 39 ] . Since conventional visible light and shortwave infrared detectors are not inherently sensitive to polarisation, additional polarisation selective optical components are required to perform full-Stokes polarisation imaging. Typically, polarisation measurements are performed using either arrays of filters, prisms, or combinations of polarisers and rotation waveplates [ 31 , 29 ] . While these methods are well-established and robust, each have limitations with regards to applications that require lightweight, compact, or single-shot systems. For multispectral polarimetry, the limitations of these conventional methods are amplified; each targeted wavelength requires additional beamsplitting or filtering to capture measurements, increasing the size of the system or decreasing photon flux. Therefore, for applications where constraints with respect to size, weight, or available light exists. Figure 1: Illustration of the proposed metasurface behaviour, demonstrating the concept of mixed wavelength incident light being diffracted into spectral and polarisation measurements for wavelength-specific single-shot polarimetry. Due to the accessibility of drones and other lightweight unmanned aerial vehicles for surveying applications, it is attractive to develop compact single-shot polarisation imaging for such platforms. One existing field of research producing compact devices is metasurface optics, which consist of a nanostructured array of metallic or dielectric optical resonators on a flat substrate. The material and shapes of the resonators produce a tailored optical response [ 15 ] , allowing metasurfaces to be used for many applications, such as prisms, lenses, waveplates, and multifunctional combinations of optical elements [ 2 , 10 , 33 , 37 ] . There are also many examples of single-shot polarisation imaging achieved with metasurfaces [ 3 , 7 , 40 , 29 , 11 , 27 , 5 ] ; however, previous works focus on monochromatic incident light, limiting the scope of applications of any one device. These works use various methods of achieving all necessary polarisation measurements, resulting in optical systems that suit different applications. We opt to separate our polarisation measurements effectively, as careful design of the metasurface will result in naturally separated spectral measurements. We present a diffractive metasurface for multispectral polarimetry at 532 nm and 700 nm as illustrated in Figure 1 , using potential agricultural remote surveying applications as a basis for our operating specifications. We also simulate critical performance metrics such as operational field-of-view and spectral bandwidth. Finally, we also present preliminary experimental characterisation of initial metasurface samples, demonstrating full-Stokes polarimetry at an incident wavelength of 532 nm, and linear polarimetry at 637 nm. 2 System Design 2.1 Field-Of-View considerations To ensure our multispectral imaging measurements don’t overlap between diffraction orders, and to take advantage of the movement of a drone-based system, we base our system around the push-broom imaging technique. This is an established technique in remote sensing and surveying, where a narrow image or “swath” is continuously imaged as the system translates perpendicular to the swath major axis. A full image is then created by stitching together adjacent images into a continuous two dimensional scene [ 9 , 16 ] . Push-broom imaging is often used in conventional multispectral imaging using a division-of-aperture technique; the imaging swath is separated into different wavelength channels, typically using a one-dimensional diffraction grating, and the channels imaged onto a two-dimensional detector. This simultaneous imaging at different wavelengths avoids errors such as illumination changing between measurements, imaging offsets between measurements, or movement within the scene. We utilise this same division-of-aperture principles for our multispectral polarimetry design to avoid these unwanted effects, using a metasurface diffracting in one direction aligned with the narrow imaging swath to naturally separate our wavelengths into distinct spectral channels, with the individual diffraction orders acting as separate polarisation measurement channels, allowing us to record all polarisation and spectral measurements simultaneously, as illustrated in Figure 2 (a). 2.2 Polarimetry measurements Full-Stokes polarimetry allows the measurement of the full polarisation state of light, including elliptical and partially polarised states, requiring a minimum of four polarisation-selective intensity measurements. The optimum measurements for a four-measurement polarimeter are well-established in literature [ 4 , 31 , 30 , 1 , 8 ] , and have been used as the analysis states in several previous metasurface polarimetry works [ 29 , 28 , 19 , 5 ] . The Stokes vector representation of light is given by \vec{S}=(S_{0},\;S_{1},\;S_{2},\;S_{3}) , where S_{0} is the total intensity of light, the S_{1},\;S_{2},\;S_{3} components define the polarisation state. For an incident Stokes polarisation state \vec{S} , and a set of polarisation-selective intensity measurements \vec{I}=(I_{-2},\;I_{-1},\;I_{1},\;I_{2}) , corresponding to the diffractively separated measurements as described in Section 1 , the relationship between the input polarisation and output measurements can be described by an instrument matrix \mathbf{M} such that: \mathbf{M}\vec{S}=\vec{I}\,. (1) Typically, the instrument matrix is not directly implemented in a polarimetry system; instead, it is calculated from the relationship between a set of calibration polarisation input states and the respective output intensity measurements. The calibrated instrument matrix is then used to reconstruct the unknown input polarisations, with the maximum likelihood method utilised for additional robustness in the calculation [ 13 , 22 ] . 3 Metasurface design framework There are two key components determining the design parameters of the metasurface; selection of the wavelengths for the multispectral polarimetry, and determining the structural parameters and design method suitable for a polarimetry metasurface operating at the chosen wavelengths. 3.1 Wavelength Selection The choice of wavelengths are based on both the target application and the diffraction angles of each wavelength. To guide our work with a practical motivation, we target the chlorophyll reflection and absorption spectral bands to enable the potential agricultural applications described earlier [ 21 ] . More critically, our chosen wavelengths must not have overlapping diffraction orders, such that there is a clearly separable signal for the \pm 1 and \pm 2 diffraction orders. Ensuring the diffractive process alone separates the wavelengths helps maintain a compact and lightweight imaging system by eliminating the need to use additional optics to separate