Real-Time Minimum-Energy Operating-Point Tracking for Battery-Powered Micro DC Motors Under Dynamically Variable Loading This work was supported by National Key R&D Program of China (2025YFE0113300), National Natural Science Foundation of China (62303407, T2293720/T2293724), Xiaomi Foundation.
Tzu-Hsiang Huang 1 , Haojian Lu 1 , Hen-Wei Huang 2,3,† , Tan Rong 4,† · 2026
Read Real-Time Minimum-Energy Operating-Point Tracking for Battery-Powered Micro DC Motors Under Dynamically Variable Loading This work was supported by National Key R&D Program of China (2025YFE0113300), National Natural Science Foundation of China (62303407, T2293720/T2293724), Xiaomi Foundation. by Tzu-Hsiang Huang 1 , Haojian Lu 1 , Hen-Wei Huang 2,3,† , Tan Rong 4,† (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-26335.txt.
Introduction
Huang and three colleagues tackled wasted energy in battery-powered micro DC motors, where cautious voltage margins guard against stalling but burn power. They showed energy per mechanical cycle dips and rises with driving voltage, reaching its cheapest point at a load-dependent voltage that moves as loading changes. A light load metric from current waveforms spots load shifts, and a two-phase adaptive voltage plan steers the motor to its cheapest operating point. Tests tracked the new minimum in both load directions within about 12 seconds.
Catalog record
| CREATOR | Tzu-Hsiang Huang 1 , Haojian Lu 1 , Hen-Wei Huang 2,3,† , Tan Rong 4,† |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 28780 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.26335
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Real-Time Minimum-Energy Operating-Point Tracking for Battery-Powered Micro DC Motors Under Dynamically Variable Loading This work was supported by National Key R&D Program of China (2025YFE0113300), National Natural Science Foundation of China (62303407, T2293720/T2293724), Xiaomi Foundation. Tzu-Hsiang Huang 1 , Haojian Lu 1 , Hen-Wei Huang 2,3,† , Tan Rong 4,† Abstract Micro DC brushed motors are widely deployed in battery-powered biomedical systems, where limited energy budgets and variable physiological loading impose stringent efficiency and safety constraints. However, conventional actuation strategies rely on conservative voltage margins to avoid stalling, leading to systematic energy inefficiency. Furthermore, existing methods primarily optimize steady-state performance, neglecting the energy required to complete individual actuation cycles under dynamic conditions. This paper reveals that the energy consumption per mechanical cycle of a DC motor exhibits a non-monotonic dependence on driving voltage, with a load-dependent minimum that shifts with external loading. Based on this insight, we propose a real-time operating-point tracking method that enables the motor to autonomously converge to its minimum-energy condition. A lightweight load metric derived from current waveform features is introduced to detect load variation, and a two-phase adaptive voltage strategy is developed to track the optimal operating point online. Experimental results demonstrate that the proposed method can track the new minimum-energy operating region under both low-to-high and high-to-low loading transitions. With 3-cycle averaging, the mean response time is 11.55s for the low-to-high case and 11.16s for the high-to-low case, while the mean convergence voltage is 2.73V and 2.0V, respectively. I INTRODUCTION Fig. 1: As the motor driving voltage decreases, the magnitude of the current rise during the loaded phase increases. Battery-powered micro actuators are fundamental building blocks in emerging biomedical devices, including ingestible electronics [ 8 ] , minimally invasive surgical tools, wearable systems, and implantable platforms [ 9 , 13 ] . In these applications, micro DC brushed motors remain attractive due to their compact size, simplicity, and compatibility with low-voltage embedded systems. However, their operation is severely constrained by limited battery capacity [ 2 ] , strict thermal limits [ 14 , 7 ] , and highly variable physiological loading conditions [ 5 ] , making energy-efficient actuation a critical challenge. In practice, micro motors in biomedical environments are often subject to uncertain and time-varying mechanical loads, arising from interactions with soft tissues, fluids, or dynamically changing anatomical structures [ 3 ] . To ensure reliable operation and avoid stalling under such conditions, these motors are typically driven using conservative voltage or current margins. While this approach guarantees sufficient torque delivery, it introduces a fundamental inefficiency: under nominal or light loading, the motor is operated with unnecessarily high current and speed, leading to excessive energy consumption, rapid battery depletion, and elevated thermal dissipation, which can compromise both device longevity and patient safety. From a mechatronic perspective, this inefficiency reflects the absence of closed-loop adaptation between electrical actuation and physiological loading. Although the electromechanical behavior of DC motors is well understood [ 1 ] , including the existence of load-dependent operating points that minimize energy consumption, such knowledge is rarely exploited in real time within biomedical systems. Instead, actuation strategies are typically fixed or pre-calibrated, lacking the ability to respond dynamically to changing in vivo conditions. Recent advances in embedded sensing and model-based estimation enable a new approach to this problem. By leveraging readily available signals—such as motor voltage, current, and rotational speed—it is possible to infer the external load experienced by the motor and adjust its operating conditions accordingly [ 10 , 6 ] . This creates an opportunity for self-adaptive, energy-aware actuation, in which the motor continuously aligns its operating point with the instantaneous mechanical demand while respecting safety constraints. Motivated by this need, this paper proposes an adaptive voltage control framework for battery-powered micro DC brushed motors in biomedical applications. The core idea is to couple a load metric mechanism with an adaptive voltage regulation strategy, enabling the motor to automatically converge toward its minimum-energy operating condition under unknown and time-varying loads. The load metric was developed based on the observation that the current rise during the loaded phase becomes more pronounced at lower driving voltages, as shown in Fig. 1 . Unlike conventional approaches that rely on conservative overvoltage to ensure robustness, the proposed method achieves both reliable operation and energy efficiency by explicitly accounting for motor loss mechanisms and load-dependent optimality. The proposed approach is particularly suited for biomedical systems due to its minimal hardware requirements and inherent safety awareness. It requires only standard electrical and kinematic measurements, making it compatible with highly constrained embedded platforms. Furthermore, the same model used for energy optimization naturally supports overload detection and thermal-aware operation, which are essential for safe interaction with biological tissues. The main contributions of this work are as follows. 1) The relationship between driving voltage and cycle energy is experimentally characterized under different loading conditions, revealing the existence and load dependence of a minimum-energy operating point. 2) A computationally simple load-sensitive metric is developed from the motor current waveform to capture load-induced changes during each mechanical cycle. 3) A real-time tracking method is designed to detect load variation and adjust the driving voltage toward the new minimum-energy operating region. By enabling actuators to adapt to their physiological environment in real time, this work advances the development of intelligent, energy-efficient biomedical mechatronic systems capable of prolonged and safe operation within the human body. II EXPERIMENTAL SETUP AND MODEL II-A Experimental Setup II-A 1 System architecture A DC power supply (UNI-T UTP1306S) is employed as the power source in the experimental system. A micro brushed DC motor equipped with a three-stage planetary gearbox with an overall gear ratio of 136:1 is employed as the actuator. A programmable output voltage DC-DC converter (Maxim Integrated, MAX77643) is employed. The motor current is measured through a current monitor (Texas Instruments, INA219) at a sampling rate of 500Hz. The microcontroller unit (Nordic Semiconductor, nRF5340 DK) is employed to read sensor data and adjust the DC-DC converter output voltage with I^{2}C interface. The overall system architecture is as shown in Fig. 2 . II-A 2 Testing mechanism and load configuration We designed and constructed a test mechanism to apply a controllable mechanical load to the motor. The mechanism converts the rotational motion of motor shaft into linear motion. The mechanical component compresses a spring during the rotation of the motor shaft thereby generating a reaction force to the motor. Springs with different spring constants are used to test and analyze the response characteristics of the motor current under different load conditions. Fig. 2: The circuit schematic of the setup II-B Brushed DC motor Dynamic Characterization A simplified electrical equation [ 11 ] of the brushed DC motor can be described by: V_{m}=I_{m}\cdot R_{m}+L_{m}\cdot\frac{dI_{m}}{dt}+V_{emf} (1) where V_{m} is the driving voltage, I_{m} is the motor current, R_{m} is the winding resistance, L_{m} is the winding inductance, and V_{emf}=K_{e}\cdot\omega_{m} is the back electromotive force (EMF) proportional to the shaft angular velocity \omega_{m} where K_{e} is the motor back-EMF constant. The mechanical equation of the motor shaft can be expressed as: \tau_{m}=J_{m}\cdot\frac{d\omega_{m}}{dt}+b_{m}\cdot\omega_{m}+\tau_{\text{load}} (2) where \tau_{m}=K_{t}\cdot I_{m} is the output shaft torque of a brushed DC motor, K_{t} is the motor torque constant, J_{m} is the rotor inertia, b_{m} is