Sub-keV energy calibration of CONUS + via 71 Ge M-shell neutron activation
E. Sánchez García e1, MPIK, Y. Shi e2, MPIK, N. Ackermann MPIK, H. Bonet MPIK, C. Buck MPIK, J. Hakenmüller MPIK, Wien, G. Heusser MPIK, M. Lindner MPIK, W. Maneschg MPIK, Mirion, M. Meier MPIK, S. Mertens MPIK, D. Piani MPIK, T. Rink KIT, H. Strecker MPIK · 2026
Read Sub-keV energy calibration of CONUS + via 71 Ge M-shell neutron activation by E. Sánchez García e1, MPIK, Y. Shi e2, MPIK, N. Ackermann MPIK, H. Bonet MPIK, C. Buck MPIK, J. Hakenmüller MPIK, Wien, G. Heusser MPIK, M. Lindner MPIK, W. Maneschg MPIK, Mirion, M. Meier MPIK, S. Mertens MPIK, D. Piani MPIK, T. Rink KIT, H. Strecker MPIK (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-25748.txt.
Introduction
Sánchez García and thirteen colleagues set the energy scale of the CONUS+ detector at sub-keV levels with neutron activation. CONUS+ recently made the first scattering detection for reactor antineutrinos on germanium. The energy scale drove most of the first result's uncertainty, at 14 percent of the predicted signal. The team irradiated a 2.4 kilogram detector with an americium-beryllium source. That run resolved the germanium-71 M-shell X-ray line for the first time. That cuts the energy-scale share of signal uncertainty to under 4 percent.
Catalog record
| CREATOR | E. Sánchez García e1, MPIK, Y. Shi e2, MPIK, N. Ackermann MPIK, H. Bonet MPIK, C. Buck MPIK, J. Hakenmüller MPIK, Wien, G. Heusser MPIK, M. Lindner MPIK, W. Maneschg MPIK, Mirion, M. Meier MPIK, S. Mertens MPIK, D. Piani MPIK, T. Rink KIT, H. Strecker MPIK |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 40172 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.25748
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Sub-keV energy calibration of CONUS + via 71 Ge M-shell neutron activation E. Sánchez García e1, MPIK, Y. Shi e2, MPIK, N. Ackermann MPIK, H. Bonet MPIK, C. Buck MPIK, J. Hakenmüller MPIK, Wien, G. Heusser MPIK, M. Lindner MPIK, W. Maneschg MPIK, Mirion, M. Meier MPIK, S. Mertens MPIK, D. Piani MPIK, T. Rink KIT, H. Strecker MPIK Abstract The CONUS + experiment has recently reported the first detection of coherent elastic neutrino-nucleus scattering (CE ν \nu NS) of reactor antineutrinos on germanium nuclei and is now entering a precision phase. The dominant uncertainty in the first measurement was the energy scale, which contributed 14% to the uncertainty of the prediction of the combined signal. We present a dedicated neutron activation campaign in which one of the new 2.4 kg CONUS + germanium detectors was irradiated with a strong 241 AmBe source, demonstrating that a contribution below 4% to the uncertainty of signal prediction is achievable. For the first time, the 71 Ge M-shell X-ray line was clearly resolved at ( 158.7 ± 1.4 ) (158.7\pm 1.4) eV ee {}_{\text{ee}} , validating the CONUS + energy reconstruction down to the detection threshold. This validation includes the understanding of the energy scale, the energy resolution, the trigger efficiency, and the correct separation of physical from noise events. These results establish the foundation for a future activation campaign at the Kernkraftwerk Leibstadt reactor site, strengthening the CONUS + energy calibration and extending its sensitivity to precision CE ν \nu NS and beyond Standard Model physics measurements. ∎ 1 1 1 [email protected] (corresponding author) 2 2 2 [email protected] (corresponding author) 3 3 3 [email protected] 1 Introduction Coherent Elastic Neutrino-Nucleus Scattering (CE \nu NS) is a Standard Model process in which neutrinos interact coherently with an entire nucleus via Z boson exchange. The scattering amplitudes from all nucleons add coherently, enhancing the cross-section by several orders of magnitude compared to other neutrino detection channels, such as inverse beta decay or elastic neutrino-electron scattering. Furthermore, the interaction is thresholdless because no charged leptons need to be produced. These properties make CE \nu NS a particularly appealing channel for reactor monitoring and for probing physics beyond the Standard Model (BSM) 42 ; 26 . There is currently a broad worldwide effort to detect CE \nu NS at reactors 11 ; 45 ; 28 ; 27 ; 2 ; 21 ; 4 ; 15 ; 18 ; 57 ; 25 ; 37 . CE \nu NS was theoretically proposed in 1974 33 ; 39 , yet more than four decades elapsed before its first experimental detection by the COHERENT collaboration 13 ; 14 ; 6 , using neutrinos produced with a pion decay at rest source. The primary experimental challenge lies in the signature of the interaction: a nuclear recoil of only a few keV, requiring detectors with exceptionally low energy thresholds and backgrounds. More recently, CE \nu NS has been observed with 8 B solar neutrinos 17 ; 22 ; 12 , and with reactor antineutrinos by the CONUS + experiment 5 . A previous claim of reactor CE \nu NS detection 28 remains in tension with the results of 4 ; 37 ; 21 , underscoring the experimental difficulty of this measurement. Following the first CE \nu NS detection, CONUS + now enters a precision phase. To this end, three of the original 1 kg high-purity germanium (HPGe) detectors have been replaced by new ones with 2.4 kg diodes, significantly increasing the target mass and thus the signal rate. The dominant uncertainty in the signal prediction in the first measurement was the energy scale, for which a conservative value of \pm 5 eV {}_{\text{ee}} (electron equivalent) was adopted. This resulted in an uncertainty of 14% in the prediction of the combined signal, nearly twice the impact of the next largest contribution, the quenching factor, with an impact at the level of 7%. Figure 1 shows the signal prediction uncertainty as a function of the energy scale uncertainty, evaluated at a reference energy of 150 eV {}_{\text{ee}} , for three realistic energy thresholds. The threshold dependence reflects the interplay between trigger efficiency and quenching. Reducing the energy scale uncertainty to \pm 3 eV {}_{\text{ee}} would render this contribution subdominant at the 4 % level. Achieving a sub-percent impact on the signal prediction requires reaching an energy scale uncertainty below \pm 1 eV {}_{\text{ee}} . Figure 1 : Signal prediction uncertainty as a function of the energy scale uncertainty, evaluated at a energy reference of 150 eV {}_{\text{ee}} for three representative energy thresholds. External sources emitting \gamma -rays cannot be used for low energy calibration in CONUS + , as the emitted low energy \gamma -rays are absorbed in the end cap of the few-millimeter-thick copper cryostat and the dead layer of the detector. The calibration therefore relies on X-ray lines produced directly within the germanium crystal through cosmogenic and neutron-induced activation. During detector fabrication and transport above ground, cosmic-ray spallation produces 68 Ge (half-life 270.95 days), 65 Zn (half-life 244.01 days) and 68 Ga (half-life 67.7 minutes). The latter is continuously produced by the decay of 68 Ge. The 68 Ge isotope is produced by spallation reactions on 70 Ge, which require fast neutrons of at least \sim 20 MeV 19 : {}^{70}\text{Ge}+n_{\text{fast}}\rightarrow\,^{68}\text{Ge}+3n (1) Similarly, 65 Zn is produced by spallation reactions on the surface of the Earth 19 : {}^{70}\text{Ge}+n_{\text{fast}}\rightarrow\,^{65}\text{Zn}+2n+^{4}\text{He} (2) In addition to these cosmogenic isotopes, 71 Ge is continuously produced in situ within the detector via neutron capture on 70 Ge (natural isotopic abundance 20.5%) by thermal, epithermal and fast neutrons with energies up to a few MeV: {}^{70}\text{Ge}+n\rightarrow\,^{71}\text{Ge}\xrightarrow{\,}^{71}\text{Ga (stable)} (3) Unlike 68 Ge, which requires fast neutrons for its production through spallation and is therefore only activated above ground, 71 Ge is produced continuously at the CONUS + experimental site by muon-induced neutrons generated in the lead shielding, leading to a K-shell line count rate of \sim 40 counts kg -1 day -1 5 . It can also be produced in larger quantities using external neutron sources such as 252 Cf or 241 AmBe. Electron capture (EC) from all these isotopes produces characteristic X-ray lines via atomic de-excitation. The dominant feature in the low-energy range is the K-shell line at 10.367 keV {}_{\text{ee}} , emitted with a branching ratio of 0.876 from both 68 Ge and 71 Ge ( 100\% EC). The corresponding L-shell lines appear at 1.298 keV {}_{\text{ee}} (L 1 , branching ratio \approx 0.119 ) and 1.143 keV {}_{\text{ee}} (L 2 , branching ratio \approx 0.001 ) 7 . Due to the proximity in energy, the L-shell emissions from 68 Ge, 71 Ge, 68 Ga and 65 Zn are observed as a single broad peak even at the high energy resolution of the CONUS + detectors. Additionally, 68 Ga contributes a K-shell line at 9.659 keV {}_{\text{ee}} , at 11.1\% of the 68 Ge K-shell intensity, and 65 Zn produces a K-shell line at 8.979 keV {}_{\text{ee}} , at 11.4\% of the 68 Ge K-shell intensity. The M-shell line at 158.1 eV {}_{\text{ee}} is emitted by both 68 Ge and 71 Ge, but has not been resolved in previous CONUS campaigns due to insufficient statistics in the M-shell