A Novel Two-Step Approach for Reactive Power Demand Calculation Using Integrated Voltage Stability Analysis

Hassan Abouelgheit, Hendrik Lens · 2026

Read A Novel Two-Step Approach for Reactive Power Demand Calculation Using Integrated Voltage Stability Analysis by Hassan Abouelgheit, Hendrik Lens (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-25016.txt.

Introduction

Abouelgheit and Lens present a two-step method for calculating reactive power demand in power systems. Their method directly calculates actual demand through a back-to-back simulation framework. It integrates long-term and short-term voltage stability sequentially, via dynamic simulation, Q-V analysis and iterative quasi-dynamic simulation. It also runs time-series analysis over a full year of 8,760 hours, with multi-criteria assessment of voltage violations. A case study shows all buses with voltage issues were addressed, and total network demand was calculated.

Catalog record

CREATORHassan Abouelgheit, Hendrik Lens
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE27832
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.25016

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Novel Two-Step Approach for Reactive Power Demand Calculation Using Integrated Voltage Stability Analysis Hassan Abouelgheit, Hendrik Lens Abstract The assessment of reactive power demand plays an instrumental role in power system planning. This paper presents a methodology for calculating reactive power demand based on a two-step approach. Unlike existing methodologies in the literature that focus primarily on optimization of reactive power compensation equipment placement and sizing through single-simulation approaches, this methodology directly calculates the actual reactive power demand through a comprehensive back-to-back simulation framework. While existing methods address either long-term or short-term voltage stability using either steady-state analysis or individual dynamic simulations, the proposed approach integrates both stability assessments sequentially through iterative Quasi-Dynamic Simulation, Q-V analysis and dynamic simulation. Furthermore, this methodology employs comprehensive time-series analysis over a full annual period (8760 hours) with multi-criteria violation assessment (number, severity and duration of voltage violations). In the final section of this paper, a case study was conducted to demonstrate the application of the proposed methodology. Simulations were performed to validate the effectiveness of the methodology, with the results showing that all buses with voltage issues were successfully addressed and finally the total reactive power demand across the network was calculated. Keywords— long-term voltage stability, short-term voltage stability, Q-V analysis, reactive power requirements, time series simulation, trajectory violation integral, dynamic simulation, power system dynamics, reactive power planning. 1 Introduction 1.1 Background The global energy sector is experiencing a rapid transformation driven by sustainability goals and climate change mitigation efforts [ 3 ] . Countries worldwide are increasing the integration of Renewable Energy (RE) into their power grids to achieve net-zero carbon emissions, with ambitious targets such as Germany’s objective of RE generation’s share of 80% by 2050 [ 12 ] . However, this transition presents significant challenges to transmission systems, mainly due to the massive integration of intermittent inverter-based resources (IBRs) such as wind and solar power generation plants [ 8 ] . In contrast to traditional power plants, IBRs produce variable and not fully predictable output, which may lead to changing operating points causing variable power flow conditions that are challenging for the system, in particular with respect to reactive power balance and voltage stability. The simultaneous phasing out of conventional synchronous generators, which historically provided system inertia and reactive power support, further complicates these issues, fundamentally changing the dynamic behavior and stability of power systems [ 26 ] . According to [ 11 ] , power system stability is classified into resonance, rotor angle, voltage, frequency, and converter-driven stability. The main focus of this research is the role of reactive power sources for voltage stability. The term voltage stability is defined as the ability of a power system to maintain steady voltages close to nominal value at all buses in the system after being subjected to a disturbance . This ability depends on the maximum power transfer and the availability of reactive power to compensate for the voltage drop resulting from power transmission or system faults. Voltage instability, primarily caused by reactive power deficiencies, can trigger voltage collapse, leading to cascading outages and widespread blackouts. The voltage stability of a system depends on the relationship between reactive power ( Q ) and voltage ( V ), where increased reactive power injections should produce voltage increases and vice-versa [ 16 ] . IBRs complicate this relationship through their diverse reactive power characteristics and intermittent nature, creating dynamic demands for reactive power compensation. Consequently, preparing electrical networks for future operating conditions with high IBR penetration is essential. Reactive Power Planning (RPP), which optimizes the type, location, and size of compensation equipments to ensure system security [ 22 ] , must incorporate voltage stability constraints. The uncertainties from intermittent renewables require new, robust methodologies to guarantee dynamic security in modern power grids. The primary objective of this work is to develop a methodology to calculate the required reactive power demand to maintain voltage stability in a given power system. Only voltage phenomena related to transmission systems such as short circuit faults, changes in power flow due to changes in generation and load situations are considered. Fault Induced Delayed Voltage Recovery (FIDVR) events related to heating and cooling applications or motor overloading such as motor-stalling are not in the scope of this work. 1.2 Related Work The increasing complexity of modern power systems driven by renewable energy integration and AC/DC hybrid networks has led to broad research on reactive power management and voltage stability. A systematic review of the existing literature reveals that prior works can be divided into three major categories based on how reactive power and voltage stability are addressed: (i) studies that formulate reactive power planning as an optimization problem with voltage as a constraint; (ii) studies that focus primarily on the development and application of voltage stability metrics and indices, with reactive power serving as an analytical rather than an optimized variable; and (iii) studies that consider reactive power in a non-systematic, application-specific, or on device-level context, without a formal optimization framework or voltage stability analysis. The most common approach in the literature, as in [ 2 , 8 , 5 , 10 , 23 , 27 , 28 ] , and [ 9 ] , is to formulate reactive power planning or optimization as a constrained mathematical problem, where the goal is to determine the optimal size and location of reactive power sources, such as capacitor banks, SVCs, or generator reactive outputs, while keeping bus voltages within acceptable limits or close to predefined values in the sense of a chosen metric. The objectives defined across these works vary. Some minimize total operating or installation cost [ 8 , 5 , 27 ] , others focus on reducing active power losses [ 2 , 23 ] , and some combine multiple goals [ 10 , 28 ] . Classical optimal power flow (OPF) methods are used, while metaheuristic approaches such as particle swarm optimization appear in [ 10 ] . More recent contributions such as [ 29 ] and [ 9 ] have turned to machine learning and reinforcement learning techniques to handle the complexity and computational efforts related to solving the problem. These studies operate under steady-state assumptions and partially address long-term voltage stability to ensure voltages remain within bounds as the system load gradually increases or decreases. Only one paper [ 9 ] in this context specifically targets short-term voltage stability by responding to fault-induced voltage sags in real time. Other research works such as [ 14 , 6 , 31 ] and [ 19 ] do not focus on optimizing reactive power, but on understanding and assessing voltage stability itself. The papers in this group develop or apply voltage stability indices to assess how close a system is to the point of voltage collapse, using reactive power as a tool for analysis rather than a variable to be controlled or determined. For instance, [ 14 ] derives an energy-function-based stability index that accounts for transformer tap changer effects, while using continuation power flow analysis to trace PV curves and identify critical loading points in systems with increasing solar PV penetration. In [ 31 ] , a Thévenin-equivalent model is used to define a Power Transfer Stability

Read the complete text