SVOM /VT: Flight Model Verification and Pre-launch Testing

Jian Zhang, Xue-Wu Fan, Gang-Yi Zou, Yu-Lei Qiu, Wei Gao, Wei Wang, Chen-Jie Wang, Ning Qi, Jin-Song Deng, Li-Jun Dan, Yue Pan, Chao Huang, Yun-Fei Du, Guo-Rui Ren, Zhong-Han Sun, Feng-Tao Wang, Wei Li, Bao-Peng Li, Chao Shen, Peng-Fei Chen, Kun Chen, Hui Zhao, Ming Chang, Tao Wang, Li-Pin Xin, Jian-Yan Wei · 2026

Read SVOM /VT: Flight Model Verification and Pre-launch Testing by Jian Zhang, Xue-Wu Fan, Gang-Yi Zou, Yu-Lei Qiu, Wei Gao, Wei Wang, Chen-Jie Wang, Ning Qi, Jin-Song Deng, Li-Jun Dan, Yue Pan, Chao Huang, Yun-Fei Du, Guo-Rui Ren, Zhong-Han Sun, Feng-Tao Wang, Wei Li, Bao-Peng Li, Chao Shen, Peng-Fei Chen, Kun Chen, Hui Zhao, Ming Chang, Tao Wang, Li-Pin Xin, Jian-Yan Wei (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-24268.txt.

Introduction

Zhang and colleagues present pre-launch testing and calibration of the SVOM Visible Telescope flight model under simulated space conditions. Tests cover thermal vacuum cycling, energy concentration checks, stray light suppression, and CCD and electronics checks for gain, noise, and quantum efficiency. Results confirm full compliance: stray light falls below one ten-millionth for point sources at 30 degrees off-axis, thermal control holds CCD temperatures, and sensitivity meets its magnitude limit. Early in-orbit tests match pre-launch specs.

Catalog record

CREATORJian Zhang, Xue-Wu Fan, Gang-Yi Zou, Yu-Lei Qiu, Wei Gao, Wei Wang, Chen-Jie Wang, Ning Qi, Jin-Song Deng, Li-Jun Dan, Yue Pan, Chao Huang, Yun-Fei Du, Guo-Rui Ren, Zhong-Han Sun, Feng-Tao Wang, Wei Li, Bao-Peng Li, Chao Shen, Peng-Fei Chen, Kun Chen, Hui Zhao, Ming Chang, Tao Wang, Li-Pin Xin, Jian-Yan Wei
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE23039
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.24268

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

SVOM /VT: Flight Model Verification and Pre-launch Testing Jian Zhang, Xue-Wu Fan, Gang-Yi Zou, Yu-Lei Qiu, Wei Gao, Wei Wang, Chen-Jie Wang, Ning Qi, Jin-Song Deng, Li-Jun Dan, Yue Pan, Chao Huang, Yun-Fei Du, Guo-Rui Ren, Zhong-Han Sun, Feng-Tao Wang, Wei Li, Bao-Peng Li, Chao Shen, Peng-Fei Chen, Kun Chen, Hui Zhao, Ming Chang, Tao Wang, Li-Pin Xin, Jian-Yan Wei Abstract This paper presents pre-launch testing and calibration results for the SVOM/VT (Space-based Variable Objects Monitor, Visible Telescope) Flight Model (FM), validating its performance under simulated space conditions through thermal vacuum cycling, energy concentration analysis, stray light suppression, and CCD/electronics calibrations (gain, noise, quantum efficiency). The results confirm full compliance with design requirements: stray light suppression achieves point-source transmittance < 10 − 7 <10^{-7} at 30° off-axis, thermal control maintains stable CCD temperatures (-75°C for the red channel, -65°C for the blue channel), and detection sensitivity meets the limiting magnitude of 22.50 (SNR >3 with 300 seconds exposure). Early in-orbit tests further validate performance, yielding limiting magnitudes of 22.70 (V-band, red) and 22.78 (blue), consistent with pre-launch specifications. \volnopage Vol.0 (202x) No.0, 000–000 keywords space vehicles: instruments – (stars:) gamma-ray burst: general – telescopes – instrumentation: detectors 1 Introduction SVOM is a Sino-French cooperative astronomical project that employs both space-borne instruments and ground-based telescopes to observe Gamma-Ray Burst (GRB) events ( 1 ; 14 ; 6 ) . Among its four scientific payloads, the Visible Telescope (VT) ( 3 ; 4 ) plays a key role in conducting high-sensitivity, two-channel (blue and red band) optical follow-up observations of gamma-ray bursts (GRBs). It also identifies high-redshift candidates to facilitate further near-infrared observations using large ground-based telescopes. In this section, we briefly introduce the composition of VT, its operation modes and key specifications. 1.1 Composition of the VT Figure 1 : Composition of the VT main body. Figure 1 shows a schematic diagram of the VT, outlining its key components—from the optical system to the CCD cooling system. Optical System The VT employs a 44 cm aperture Ritchey-Chrétien (RC) optical system (f/8 focal ratio). Its lightweight silicon carbide (SiC) primary mirror, coated with high-reflectivity silver, achieves a surface accuracy less than 1/50 \lambda . The secondary mirror is optimized to support the wide field of view (FOV) required for mounting two Fine Guidance Sensors (FGS) alongside the main CCD in the blue channel’s focal plane. Dual-Channel Imaging A dichroic beam splitter divides incident light into red (400–650 nm) and blue (650–1000 nm) channels, directing each to dedicated CCDs. The beam splitter exceeds 95% transmittance and reflectivity efficiency in both bands, ensuring precise co-alignment and maximizing throughput for rapidly evolving transients like gamma-ray bursts (GRBs). Detectors Both channels provide a 26^{\prime} × 26^{\prime} FOV at 0.77^{\prime\prime}/pixel , utilizing e2v 42-80 2048 × 2048 CCDs(13.5 µm pixels) optimized for their respective bands: • Red Channel: Deep-depletion, back-illuminated CCD (QE \sim 60\% at 900 nm), operating in Non-Inverted Mode (NIMO). • Blue Channel: Thinned, back-illuminated CCD (QE \sim 90\% at 550 nm), operating in Advanced Inverted Mode (AIMO). Calibration System The integrated calibration unit acquires bias, dark, and flat-field frames using a motorized shutter coated with diffusing material, which acts as a flat-field source when illuminated by LEDs. For the blue channel, LEDs emit wavelengths of 470nm, 527nm, and 640nm, while the red channel uses 670nm, 740nm, and 870nm. When the shutter is closed, the system captures bias frames (zero-second exposures) and dark frames (LEDs off), and when the shutter is illuminated, multi-wavelength flat-field frames (LEDs on) are obtained. Stray Light Suppression The primary and secondary mirror baffles prevent skylight from directly illuminating the detectors without first reflecting off the mirrors. The outer baffle and tube block off-axis light (beyond 24°) from reaching the primary mirror. To further suppress stray light, all inner surfaces of the baffles and tube are coated with anti-reflective materials and fitted with light-trapping vanes. When light from bright off-axis sources enters the telescope, it undergoes multiple reflections within the outer baffle and tube before reaching the primary mirror. This trapped light is further attenuated by the anti-reflective coatings and baffle vanes on the inner surfaces of the primary and secondary mirror baffles, minimizing stray light contamination. Focusing and Aberration Correction To correct the residual aberration of the RC configuration, the VT employs three lenses positioned near the primary mirror (PM). The first two lenses are motor-driven and move along the optical axis to adjust focus. The Cooling system for CCDs To decrease the dark current, the working temperatures of CCDs must be lowered to an appropriate level. Due to differences in operation modes between the two CCDs, the dark current in the red-band CCD (operated in Non-Inverted Mode, NIMO) is significantly higher than that of the blue-band CCD (operated in Advanced Inverted Mode, AIMO) at the same temperature. To mitigate this, the operating temperature of the red-band CCD (-75°C) is set lower than that of the blue-band CCD (-65°C). Each CCD uses a two-stage Thermo-Electric Cooler (TEC) which connects to a dedicated heat radiator with heat pipes for cooling. A schematic diagram of the CCD temperature control design is shown in Figure 2 . Figure 2 : Heat dissipation path of the CCD. Left: red band, Right: blue band. 1.2 Operation Modes in Orbit Below is a brief overview of VT’s primary operation modes (see Fig. 3 ) Imaging Mode The default mode for observations, configurable via parameters such as exposure time, readout mode, readout speed, and window size. SAA and Earth Occultation Modes Automatically deactivates CCD sensors when the satellite enters the South Atlantic Anomaly (SAA) region or Earth’s occultation to protect hardware. Calibration Mode Performs periodic in-flight calibrations to correct radiation-induced hot pixels and maintain data quality. Bake-out Mode Mitigates radiation damage by heating the detector to 25°C (CCD annealing) when required. Safe Mode Activated during anomalies, this mode powers down non-critical systems while maintaining thermal control. Optical components are stabilized at safe temperatures, and CCDs remain passively cooled. Figure 3 : VT operation modes in orbit. The VT is within the imaging mode at most of the time, expect for some reason it could change its woking statue to another mode. 1.3 Key Specifications Table 1 : VT Key Specifications No Item Specification 1 Telescope aperture 440 mm 2 Focal length 3600mm 3 Field of view 26^{\prime} × 26^{\prime} 4 Filter band-pass 400nm-650nm, 650nm-1000nm 5 Encircled energy for red radius of EE70 within 1.0 arcsecond 6 Encircled energy for blue The radius of EE80 within 1.5 arcsecond 7 Stray light suppression < 1/3 sky background when the moon is > 30° off optical axis 8 Red CCD working temperature -75°C±2°C 9 Blue CCD working temperature -65°C±2°C 10 Readout noise < 6e - /pix @100KHz Table 1 summarizes the key specifications of the VT, as tested and calibrated on the FM. The pre-launch testing procedures, calibration methods, and their results are detailed in the following section. 2 The pre-launch experiments, tests and calibrations 2.1 The Thermal Vacuum Experiment 2.1.1 Thermal Environment Analyses of the VT in Orbit The thermal vacuum experiment aims to validate the VT’s operational adaptability to varying thermal conditions in space. After assembly, most of the VT’s opto-mechanical structure (see Fig. 4 ) is housed

Read the complete text