The Simons Observatory: Improved Cryogenic Struts for use in the Large Aperture Telescope Receiver Journal: Cryogenics
John Orlowski-Scherer, Anna Kofman, Tanay Bhandarkar, Mark Devlin, Saianeesh K. Haridas, Jeff Iuliano, Alex Manduca, Robert J. Thornton · 2026
Read The Simons Observatory: Improved Cryogenic Struts for use in the Large Aperture Telescope Receiver Journal: Cryogenics by John Orlowski-Scherer, Anna Kofman, Tanay Bhandarkar, Mark Devlin, Saianeesh K. Haridas, Jeff Iuliano, Alex Manduca, Robert J. Thornton (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-21975.txt.
Introduction
Orlowski-Scherer and seven colleagues report a glue joint in a strut for the Simons Observatory telescope receiver. Stiff, cryogenically insulating struts keep detectors at temperatures and locations. A tapped hole and set screw profile the joint's walls, changing failure mode from adhesive to cohesive. The joint's yield strength is 10 percent higher than a smooth-walled design, and ultimate strength 33 percent higher. Measured yield versus predicted load gives a factor of safety of 7. The struts served three years with cycles from 300 kelvin to 100 millikelvin and no damage.
Catalog record
| CREATOR | John Orlowski-Scherer, Anna Kofman, Tanay Bhandarkar, Mark Devlin, Saianeesh K. Haridas, Jeff Iuliano, Alex Manduca, Robert J. Thornton |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 21028 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.21975
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The Simons Observatory: Improved Cryogenic Struts for use in the Large Aperture Telescope Receiver Journal: Cryogenics John Orlowski-Scherer, Anna Kofman, Tanay Bhandarkar, Mark Devlin, Saianeesh K. Haridas, Jeff Iuliano, Alex Manduca, Robert J. Thornton Abstract The Simons Observatory Large Aperture Telescope Receiver (SO LATR) is a next generation Cosmic Microwave Background camera equipped with > 60,000 >60,000 detectors operating at 100 100 mK. Maintaining these detectors at the correct temperatures and locations requires stiff, cryogenically insulating struts. In this paper we report the design and performance of a novel glue joint in a strut used in the SO LATR to achieve the required performance. We use a tapped hole and set screw to create a profile on the exterior and interior wall of the glue joint, respectively, which greatly increases the strength of that joint by changing the failure mode from adhesive to cohesive. The failure mode of the resulting glue joint is cohesive with a yield strength 10 % 10\% higher than a comparable smooth-walled design, and an ultimate strength 33 % 33\% higher. Comparisons of the measured yield strength to the predicted axial load on the strut from simulations results in a factor of safety for the strut of 7. These struts have been installed in the SO LATR for three years and have undergone numerous thermal cycles from 300 300 K to 100 100 mK with no evidence of damage to the glue joint. 1 Introduction The Simons Observatory ( 2 , SO;) is a next-generation Cosmic Microwave Background (CMB) experiment, which recently began observations from its 5200 m elevation site on Cerro Toco in northern Chile. The observatory consists of three Small Aperture Telescopes ( 5 , SATs;) and one Large Aperture Telescope telescope ( 11 , LAT;) . The LAT will make an arcminute resolution map of approximately 60% of the sky in both temperature and polarization, which will advance many priorities in cosmology – for example by precisely measuring the damping tail of the CMB power spectrum and identifying galaxy clusters as tracers of mass in the universe. With over 60,000 Transition Edge Sensor detectors in the LAT due to the recent Advanced SO upgrade ( 9 , ASO;) and another 35,000 in the three SATs, the SO maps will rapidly become the deepest of their kind ever made. In order to detect the \mu K scale fluctuations in the CMB, SO uses transition edge sensors ( 6 , TESes;) . TESes work by holding a strip of metal on its superconducting transition. The TESes need to operate at cryogenic temperatures, at least \lesssim 250 mK but ideally \sim 100 mK. Therefore, one of the primary challenges of the LAT design process was to plan a cryostat large enough to house >60,000 ASO TESes while maintaining a stable base temperature of \leq 100 mK. The result of that design process is the LAT Receiver ( 12 ; 7 , LATR;) . The receiver is split into multiple temperature stages – 300 K, 80 K, 40 K, 4 K, 1 K, and 100 mK – which are cooled via Pulse Tube (PT; 80,40,4 K) coolers and a Dilution Refrigerator (DR, 1 K and 100 mK). Within the LATR, the detectors are housed in 13 separate optics tubes (OTs), which contain reimaging optics and filters in addition to the detectors. The OTs contain three temperature stages, 4 K, 1 K, and 100 mK. The DR is thermally connected to the 1 K and 100 mK stages in the OTs via the thermal back-up-structure (BUS). The thermal BUS consists of two copper plates, one at 1 K and one at 100 mK, which are connected by carbon fiber trusses. Figure 1: Diagram showing the thermal BUS truss in-situ in the LATR. The left image shows the thermal BUS as installed in the LATR. The top right image is a side view of the thermal BUS, showing the distribution of the six trusses around the perimeter of the thermal BUS. The bottom left image is a detail of a strut, showing the feet, carbon fiber rod, and external glue joint. This paper details the novel design of the carbon fiber struts used in the construction of the LATR thermal BUS. These struts are constructed by gluing carbon fiber rods into aluminum feet. In this configuration, the glue joint is generally the first point of failure when loading the truss to its limit 1 1 1 Throughout, a strut is a single glued carbon fiber and aluminum element, while the truss is the entire assemblage of struts . We describe here a novel approach to this glue joint, and related measurements associated with the development of the LATR trusses. Related work was done to develop trusses for the SATs, which is detailed in 4 . This paper is organized as follows. In Section 2 we describe the design of the struts and in particular of their glue joints. In Section 3 we describe the finite element analysis done to predict the structural performance of these struts. In Section 4 we describe the testing methodology used to evaluate the performance of these struts, while in Section 5 we present the results of that testing. Finally, in Section 6 we summarize the results of this paper and present some recommendations for future improvements. 2 Design The design of the strut is comprised of the carbon fiber tube itself, glued at both ends into 6061 aluminum “feet” which provide a mating interface to the thermal BUS. Figure 1 shows a fully assembled truss as installed in the thermal BUS. The novelty in our design lies in the gluing interface between the carbon fiber tube and the feet. For many truss designs, including our own, the limiting factor, in terms of both yield and ultimate strength is not the carbon fiber but the glue joint. The advantage of a truss design is that, to good approximation, each individual member is under only tension or compression, with negligible shear forces. This makes good use of the high tensile strength of carbon fiber ( 10 , e.g.;) ; however, it places significant strain on the glue joint, as the forces on the strut are shearing the glue. This may cause the glue to fail, either adhesively, via detachment of the glue from one of the glued surfaces, or cohesively, when the glue itself fractures. Our novel design increases the glue joints’ strength by adding a profile to the surfaces of the strut feet which are glued to the carbon fiber rods. In early designs for this strut, the gluing interface was simply a cut annulus, slightly larger in outer diameter and smaller in inner diameter than the carbon fiber tube. In testing, these simple designs would fail adhesively, short of the cohesive failure limit. We therefore set out to design a new interface which would fail cohesively, gaining strength in our strut design. 2.1 Glue Joint The design we settled on is shown in Figure 2 . It is still an annulus, but now the profile of both walls is zig-zagged. This has a double effect: firstly, it reduces the shear force on the glue by a factor of \cos(\theta) where \theta is the angle