Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8 Preprint: APS/123-QED

Shinya Yamada, Yuto Ichinohe, Hideyuki Tatsuno, Ryota Hayakawa, Hirotaka Suda, Takaya Ohashi, Yoshitaka Ishisaki, Tomoya Uruga, Oki Sekizawa, Kiyofumi Nitta, Yoshio Takahashi, Takaaki Itai, Hiroki Suga, Makoto Nagasawa, Masato Tanaka, Minako Kurisu, Tadashi Hashimoto, Douglas Bennett, Ed Denison, William (Randy) Doriese, Malcolm Durkin, Joseph Fowler, Galen O’Neil, Kelsey Morgan, Dan Schmidt, Daniel Swetz, Joel Ullom, Leila Vale, Shinji Okada, Takuma Okumura, Toshiyuki Azuma, Toru Tamagawa, Tadaaki Isobe, Satoshi Kohjiro, Hirofumi Noda, Keigo Tanaka, Akimichi Taguchi, Yuki Imai, Kosuke Sato, Tasuku Hayashi, Teruhiko Kashiwabara, Kohei Sakata · 2026

Read Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8 Preprint: APS/123-QED by Shinya Yamada, Yuto Ichinohe, Hideyuki Tatsuno, Ryota Hayakawa, Hirotaka Suda, Takaya Ohashi, Yoshitaka Ishisaki, Tomoya Uruga, Oki Sekizawa, Kiyofumi Nitta, Yoshio Takahashi, Takaaki Itai, Hiroki Suga, Makoto Nagasawa, Masato Tanaka, Minako Kurisu, Tadashi Hashimoto, Douglas Bennett, Ed Denison, William (Randy) Doriese, Malcolm Durkin, Joseph Fowler, Galen O’Neil, Kelsey Morgan, Dan Schmidt, Daniel Swetz, Joel Ullom, Leila Vale, Shinji Okada, Takuma Okumura, Toshiyuki Azuma, Toru Tamagawa, Tadaaki Isobe, Satoshi Kohjiro, Hirofumi Noda, Keigo Tanaka, Akimichi Taguchi, Yuki Imai, Kosuke Sato, Tasuku Hayashi, Teruhiko Kashiwabara, Kohei Sakata (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-21846.txt.

Introduction

Yamada and 42 colleagues operate a transition-edge sensor spectrometer at the SPring-8 synchrotron X-ray source and evaluate its performance. The system runs 220 pixels at once, with energy resolution of 4 electron volts at 6 kilo-electron volts and about 1 count per second per pixel. A compromise for high count rates gives about 2,000 counts per second across all pixels at 5 electron volts resolution. Wide-band spectroscopy then enables simultaneous multi-element analysis, resolving weak fluorescence lines in dilute samples and trace elements, including neighbouring arsenic and lead lines.

Catalog record

CREATORShinya Yamada, Yuto Ichinohe, Hideyuki Tatsuno, Ryota Hayakawa, Hirotaka Suda, Takaya Ohashi, Yoshitaka Ishisaki, Tomoya Uruga, Oki Sekizawa, Kiyofumi Nitta, Yoshio Takahashi, Takaaki Itai, Hiroki Suga, Makoto Nagasawa, Masato Tanaka, Minako Kurisu, Tadashi Hashimoto, Douglas Bennett, Ed Denison, William (Randy) Doriese, Malcolm Durkin, Joseph Fowler, Galen O’Neil, Kelsey Morgan, Dan Schmidt, Daniel Swetz, Joel Ullom, Leila Vale, Shinji Okada, Takuma Okumura, Toshiyuki Azuma, Toru Tamagawa, Tadaaki Isobe, Satoshi Kohjiro, Hirofumi Noda, Keigo Tanaka, Akimichi Taguchi, Yuki Imai, Kosuke Sato, Tasuku Hayashi, Teruhiko Kashiwabara, Kohei Sakata
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE66517
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.21846

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8 Preprint: APS/123-QED Shinya Yamada, Yuto Ichinohe, Hideyuki Tatsuno, Ryota Hayakawa, Hirotaka Suda, Takaya Ohashi, Yoshitaka Ishisaki, Tomoya Uruga, Oki Sekizawa, Kiyofumi Nitta, Yoshio Takahashi, Takaaki Itai, Hiroki Suga, Makoto Nagasawa, Masato Tanaka, Minako Kurisu, Tadashi Hashimoto, Douglas Bennett, Ed Denison, William (Randy) Doriese, Malcolm Durkin, Joseph Fowler, Galen O’Neil, Kelsey Morgan, Dan Schmidt, Daniel Swetz, Joel Ullom, Leila Vale, Shinji Okada, Takuma Okumura, Toshiyuki Azuma, Toru Tamagawa, Tadaaki Isobe, Satoshi Kohjiro, Hirofumi Noda, Keigo Tanaka, Akimichi Taguchi, Yuki Imai, Kosuke Sato, Tasuku Hayashi, Teruhiko Kashiwabara, Kohei Sakata Abstract We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron X-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of 4 4 eV at 6 keV at a rate of ∼ \sim 1 c/s/pixel. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of ∼ 2 × 10 3 \sim 2\times 10^{3} c/s/all pixels with an energy resolution of 5 5 eV at 6 keV. By utilizing the TES’s wide-band spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted X-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The neighboring lines of As K α \alpha and Pb L α ​ 2 \alpha 2 of the standard sample were clearly resolved and the XANES of Pb L α ​ 2 {\alpha}2 was obtained. Moreover, the X-ray spectrum from the small amount of Fe in aerosols was distinguished from the spectrum of a blank target, which helps us to understand the targets and the environment. These results are the first important step for the application of high resolution TES-based spectroscopy at hard X-ray synchrotron facilities. I Introduction X-ray absorption (XAS) and X-ray fluorescence (XRF) or X-ray emission spectroscopy (XES) are powerful techniques to measure distribution, chemical state, and local structure of elements. Therefore, they play essential roles in various materials analyses. For example, diagnostics for trace elements are conducted by measuring the energy spectrum of fluorescent X-rays. Instruments for performing X-ray spectroscopy are primarily categorized into wavelength-dispersive or energy-dispersive spectrometers. XAS of trace elements has typically been conducted using Si or Ge-based energy-dispersive X-ray detectors. The typical energy resolution of these detectors is about 120 eV in the hard X-ray energy region ( > 4 keV), which is fundamentally limited by statistical variation of the number of electron-hole pairs created by X-ray photon absorption. However, that resolution is insufficient to fully distinguish the nearly overlapping K and L emission lines of elements in this energy regions ( < 15 keV), which hinders the ability of trace element analysis to effectively measure natural or otherwise complicated samples. In cases where it is necessary to resolve closely-spaced emission lines, a Bent Crystal Laue Analyzer (BCLA) is used in combination with energy-dispersive X-ray detectors 13 . The energy resolution of this system is several tens of eV. However, XES measurements require high energy resolution, less than 10 eV, and are therefore normally conducted using a wavelength-dispersive bent multi-crystal analyzer spectrometer. The detection efficiency of the BCLA was limited due to narrow acceptance angle and low diffraction efficiency of the analyzer crystals. The analyzer crystals need to be changed depending on the energy region of interest. Recently, multi-crystal spectrometers based on intersecting Rowland circles have been developed and enhanced the solid angle and the detection efficiency (e.g., 44 and 18 ). In such a system, the detectors and the crystals need to be located at a certain distance from the sample, which have a limit to increase the efficiency and the bandpass of the energy range. These situations demand high-efficiency energy-dispersive X-ray detectors having energy resolution less than 10 eV. The first technology to deliver this type of performance came in the form of semiconductor type microcalorimeters operating at 50 mK. To achieve high energy resolution, operating the detectors at such low temperature is essential since the creation energy of the pairs (e.g., \sim eV for electron and hole pairs in semiconductors, and \sim meV for Cooper pairs in superconductors) and the thermal noise decreases. Recently, the semiconductor type microcalorimeters, such as the Soft X-ray Spectrometer (SXS) on the X-ray astronomical satellite called ASTRO-H (Hitomi) 11 , succeeded in solving several issues related to vibration from the cryogenic system 48 and achieved an energy resolution of 4.5 eV at 6 keV in a space environment. Its high energy resolution clearly resolved ionized iron lines and revealed that the hot plasma stored in the galaxy cluster has low turbulent pressure 6 . Although there is now a great deal of accumulated experience using semi-conductor X-ray microcalorimeters, their high impedance limits the increase of the number of pixels for practical use, and hence the collection area is fundamentally limited because the heat capacity, and therefore the size, of a single pixel is also limited by its required energy resolution. A promising alternative candidate is the superconducting transition-edge sensor (TES) 20 . Since a way of stabilizing the TES within its narrow transition region was formulated in the mid-1990s 19 , the technical details and physical nature of these devices have been intensively studied, with strong demand from both on-ground and space applications 12 . Thanks to these advances, the TES has been chosen as the detector technology for the future European X-ray observatory called ATHENA 8 , which is planned to have an array of more than three thousand sensors. However, in order to successfully integrate a TES array into other systems in an experiment, the spectrometer design must overcome several difficulties, including suppressing mechanical vibration, isolating electrical interference, shielding against magnetic fields, and synchronizing its timing with other systems. The National Institute of Standards and Technology (NIST) has developed a mature 240-pixel TES spectrometer, which was applied to nuclear physics research at Japan Proton Accelerator Research Complex (J-PARC) 10 and succeeded in measuring fluorescence lines from a Kaonic atom 15 , achieving stable performance even in the challenging environment found at an accelerator. The TES can be applied to a diverse area of scientific problems by changing its design, e.g., thickness or size of TESs and absorbers, to cover a wide range of energies and celestial or terrestrial X-ray sources. For example, the TES can be applied as a particle detector to search for a dark matter via inelastic scattering 53 , or to measure the mass of neutrinos 9 . Today, TES X-ray spectrometers are operated for several different applications: e.g., at the Stanford Synchrotron Radiation Lightsource beamline 10-1 (BL 10-1) 29 , at the Electron Beam Ion Trap (EBIT) at NIST 46 , for resonant soft X-ray scattering at the Advanced Photon Source 24 , for particle-induced X-ray emission (PIXE) 37 , and for ultrafast time-resolved

Read the complete text