Designing interferometers within a single optical beam

Bereneice Sephton, Rakhi Thomas, Carlo Schiano, Francesco Reda, I Komang Januariyasa, Filippo Cardano, Bruno Piccirillo, Marcella Salvatore, Stefano Luigi Oscurato, Corrado de Lisio and Vincenzo D’Ambrosio · 2026

Read Designing interferometers within a single optical beam by Bereneice Sephton, Rakhi Thomas, Carlo Schiano, Francesco Reda, I Komang Januariyasa, Filippo Cardano, Bruno Piccirillo, Marcella Salvatore, Stefano Luigi Oscurato, Corrado de Lisio and Vincenzo D’Ambrosio (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-21485.txt.

Introduction

Bereneice Sephton and 10 colleagues design custom interferometers inside a single optical beam using structured light, dodging the stability-versus-complexity trade-offs of usual setups. Their common-path setups need no complex post-processing and fit into existing setups. A range of interferometers, each shaped by its structured mode and built with active and passive modal conversion optics, proves adaptability. Applied to precise phase imaging across varied samples, results match atomic force microscopy benchmarks, and mapping phase objects to amplitude or polarization opens real-time phase retrieval.

Catalog record

CREATORBereneice Sephton, Rakhi Thomas, Carlo Schiano, Francesco Reda, I Komang Januariyasa, Filippo Cardano, Bruno Piccirillo, Marcella Salvatore, Stefano Luigi Oscurato, Corrado de Lisio and Vincenzo D’Ambrosio
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE45421
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.21485

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Designing interferometers within a single optical beam Bereneice Sephton, Rakhi Thomas, Carlo Schiano, Francesco Reda, I Komang Januariyasa, Filippo Cardano, Bruno Piccirillo, Marcella Salvatore, Stefano Luigi Oscurato, Corrado de Lisio and Vincenzo D’Ambrosio Abstract Interferometry provides highly sensitive access to optical phase and is central to much of modern metrology and phase imaging methods. Conventional implementations, however, often face trade-offs between mechanical stability and experimental or computational complexity. Here, we present a general framework for designing custom interferometers within a single optical beam by exploiting structured light. This approach yields compact, robust common-path configurations that bypass the need for complex post-processing and can easily be integrated into existing setups. We demonstrate the versatility of this concept by designing a range of interferometers, each tailored by the structured mode, and implement them through active and passive modal conversion optics, proving its adaptability to different experimental requirements. To showcase the practical utility of our framework, we apply it to quantitative phase imaging over a variety of physical samples, showing excellent agreement with atomic force microscopy benchmarks. Furthermore, we emphasise the flexibility of our structured light interferometers by mapping phase objects to a choice of either amplitude or polarisation, the latter providing a direct route toward real-time phase-retrieval. This cost-effective approach offers a practical, high-throughput solution for phase-sensitive metrology across fields such as fundamental physics, biology, and material science. Purposefully tailoring the amplitude and phase of light forbes2021structured ; he2022towards has wide-reaching impact, facilitating applications from optical trapping yang2021optical to communications willner2021orbital . Alternatively, retrieving the phase structure of light is less direct as the inherent phase insensitivity of conventional image sensors necessitates indirect approaches, such as interferometry, where a reference beam is mixed with the signal beam ichioka1972direct ; frantz1979optical ; van2022optical ; cui2022quantitative ; besse2012spatially . This approach provides highly sensitive, non-contact phase measurements and finds use in surface metrology zhao2025review , precision displacement sensing huang2024review , and optical coherence tomography huang1991optical ; bouma2022optical . In particular, traversing samples can reveal important information such as topography de2015principles and composition, essential in biological, medical park2018quantitative and material applications fang2017nanomanufacturing ; brand1995calibration ; dai2005accurate , giving way to the thriving field of quantitative phase imaging nguyen2022quantitative ; chaumet2024quantitative ; huang2024quantitative . Unfortunately, light beams propagating along spatially separated paths usually result in instability shaked2012quantitative ; bai2015common ; rodriguez2024axis , requiring either active correction krishnamachari2006active ; hacker2023phase or periodic realignment, and generally need bulky frameworks, which are not simple to integrate into existing systems. This has inspired a myriad of alternative strategies park2018quantitative ; mir2012quantitative ; nguyen2022quantitative , which often compromise between experimental and computational complexity. Moving away from traditional interferometry removes the instability associated with a reference arm, but typically requires significant computational overhead streibl1984phase ; paganin1998noninterferometric ; barone2002quantitative ; tian20153d ; katkovnik2017computational ; wu2021wavelength ; garcia2006digital ; gao2023iterative ; sun2023compressive . Segmented approaches, such as Shack–Hartmann wavefront sensors gong2017optical , avoid interferometric instability but at the cost of reduced resolution mir2012quantitative . Alternatively, common-path interferometry seeks to provide stability with reduced computational complexity by having both beams travel along the same or very similar paths nguyen2022quantitative . For instance, double-passing schemes dyson1957common ; dyson1963very ; bvehal2019quantitative ; wei2020w minimally separate the reference and send it back in the same path, shear interferometry schreiber1997lateral ; bates1947wavefront ; murty1970compact ; aleman2019shearing replicates and interferes the beam with itself, and self-referencing interferometry singh2012lateral ; lee2014quantitative ; bvehal2019quantitative ; sardana2023dielectric places the sample in only a part of a duplicated beam so that the structured areas do not overlap. Choice of each approach often relies on respectively reconciling between varying trade-offs. Namely, bulky and complex experimental configurations, additional extraction calculations or resolution limitations with sample size to reference overlap constraints. Figure 1: Structured light as an interferometer. (a) Traditional interferometers use elements such as beam-splitters (BS) to split light into two paths (1 and 2) before recombining them to observe any phase differences that now modulate the intensity of the exiting light. (b) Light can similarly be split (forward arrow) into two separate collinear optical modes ( \Phi_{1} and \Phi_{2} ) using phase-modulating optical elements which we refer to as mode-splitters (MS). Performing the reciprocal operation (reverse arrow) recombines the light back into the same optical mode, forming a structured light interferometer. Insets (a,b) highlight these splitting operations with the modes in (b) shown after propagation for conceptual clarity. (c) Structured light interferometers can be used to perform quantitative phase imaging where modes with vortex, Bessel or displaced structures, for example, become a reference (Ref.) which propagates alongside another Gaussian mode (Pr.) that probes an object (Obj.) before being recombined by reversing the generation process. Inset (i) illustrates how spatial separation between the structured vortex and unstructured Gaussian components allows only the probe to interact with the object of interest. By using polarisation-sensitive structuring elements as MS we selectively mark and revert the structured mode for interference upon recombination. Recombination operations either (d) return the reference polarisation to that of probe and map the object phase directly into intensity or (e) retain the orthogonal polarisation and map the object phase to the polarisation structure instead. A \pi -step phase object is shown to illustrate the effect. Arrows on the intensity distributions represent local polarisation states. In this paper, we introduce a common-path approach that uses structured light modes to form a collinear interferometer, which we term a structured light interferometer (SLI). This provides a compact and robust single-beam geometry that offers a versatile route to interferometric design with minimal computational overhead. Here, structuring the optical field splits it into co-propagating probe and reference modes that act as conventional interferometer arms. Reversing this transformation recombines these modal arms into a single, interfering spatial mode. This common-path nature inherently suppresses environmental phase noise, providing improved stability compared to conventional interferometers. We illustrate the generality of our approach using three different modal families and across both passive and dynamic technologies, each giving rise to a tailored interferometric design in a quantitative phase imaging setting. Furthermore, we show that phase information can be mapped to either the intensity or the polarisation of the output beam. In each case, we obtain excellent reconstruction of phase samples with different geometries. Together, these results establish a robust and flexible approach for phase-sensitive metrology with minimal post-processing. This provides a practical route to non-contact, real-time measurements across biology, materials science and industry that are easily integrated and can be tailored for each application. Results Structured light interferometers. In traditional interferometry, light is split into different paths and then recombined, often using beam splitters (Fig. 1 (a)). Inspired by this principle, we exploit modulation optics as mode splitters (MSs) to divide the optical field into two spatially distinct modes and subsequently recombine them back into a single one. Figure 1 (b,c) illustrates our concept where the interferometer is formed between generation and recombination MSs. The first MS imparts structure to the optical field traversing it, while the second performs the inverse transformation. In between, the co-propagating modes separate spatially to form the individual arms of the SLI. Here, full control relies on addressing each mode independently. By choosing polarisation as the discriminating degree of freedom, mode-selective operations are possible with readily available optical elements such

Read the complete text