A Dynamic Phasor Framework for Analysis of IBR-Induced SSOs in Multi-Machine Systems
Fiaz Hossain, Nilanjan Ray Chaudhuri, and Constantino M. Lagoa · 2026
Read A Dynamic Phasor Framework for Analysis of IBR-Induced SSOs in Multi-Machine Systems by Fiaz Hossain, Nilanjan Ray Chaudhuri, and Constantino M. Lagoa (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-21234.txt.
Introduction
Fiaz Hossain, Nilanjan Ray Chaudhuri, and Constantino Lagoa build a dynamic phasor framework for power grids where inverters induce slow oscillations. Because the framework stays linear and time-invariant, mode analysis can trace each oscillation to its root cause and guide damping-controller design. Case studies on a modified IEEE two-area system check the model against EMTDC/PSCAD simulations. A robust decentralized damping controller then quiets the modes, including after unbalanced faults and under data-center loads.
Catalog record
| CREATOR | Fiaz Hossain, Nilanjan Ray Chaudhuri, and Constantino M. Lagoa |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 26866 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.21234
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Dynamic Phasor Framework for Analysis of IBR-Induced SSOs in Multi-Machine Systems Thanks: Financial support from NSF Grant Award ECCS 2317272 is gratefully acknowledged. Fiaz Hossain, Nilanjan Ray Chaudhuri, and Constantino M. Lagoa Abstract We propose a generalized dynamic phasor (DP) framework to analyze inverter-based resources (IBRs) connected to multi-machine systems under balanced and unbalanced conditions. It captures subsynchronous oscillations (SSOs) induced by grid-following (GFL) IBRs. The linearizability and time invariance of the framework enables us to perform eigen decomposition, which is a powerful tool for root-cause analysis of the SSO modes and damping controller design. The same framework also enables analysis of excitation of the SSO modes in presence of data center (DC) loads. The GFL IBRs are modeled in their respective d q dq -frame DPs and the detailed model of synchronous generators (SGs) along with dynamic transmission network models are represented in p n z pnz -frame DPs. Several case studies are performed on the modified IEEE two-area benchmark system, where 2 2 SGs are replaced by GFL IBRs and validated with EMTDC/PSCAD simulations. First, time- and frequency-domain analyses of the SSO mode are presented followed by the design of a robust decentralized ℋ ∞ \mathcal{H}_{\infty} damping controller based on local signals of the GFL IBRs. Second, the dynamic behavior of the system following an unbalanced fault is demonstrated that is damped by the proposed damping controller. Finally, excitation of the SSO mode in presence of DC load is exhibited and its locational impact is analytically quantified. I Introduction Subsynchronous oscillations (SSOs) induced by grid-following inverter-based resources (GFL IBRs) are becoming prevalent in grids [ 1 ] and recent growth of data center (DC) loads can potentially excite such modes and pose reliability risks [ 8 ] . Although such phenomena can be captured using the state-of-art commercial electromagnetic transient (EMT) simulation platforms, they have certain limitations including scalability issues due to heavy computational burden and unsuitability in deriving linear time invariant models that allow frequency-domain analysis. Dynamic phasor (DP)-based modeling approach [ 11 ] works as a complementary tool that can employ adaptive time-steps and run faster time-domain simulations compared to traditional EMT platforms because – (a) the users can select the order of DP coefficients to limit the frequency of modes captured, and (b) the framework is time-invariant. The framework is capable of simulating large disturbances including balanced and unbalanced short circuit faults in presence of IBRs. The linearizability and time-invariance of DP models allow eigenvalue decomposition that can help identify the SSO modes, perform root cause analysis, and facilitate design of controllers, including damping controllers of such modes. In published literature, application of the DP framework has been largely confined to systems involving a single machine or a single IBR, see for example [ 12 , 2 , 5 ] that considered unbalance simulation. Although [ 13 ] claims to develop a DP-based model of a one-synchronous generator (SG)-two-IBR system, the concepts of DP and space phasor are used interchangeably in that work. Moreover, the modeling framework only considers balanced conditions, and the component-level models are hardly described. The DP-based model of an aircraft power system is presented in [ 14 ] where a few SGs are connected in parallel, and unlike terrestrial grids, there are no transmission lines and IBRs. Therefore, the scalability of the DP-based framework in modeling multi-machine systems with IBRs capable of unbalanced simulation has thus far not been shown. To our knowledge, this is one of the first works that takes a step towards filling that gap. The main contributions of this paper are the following. 1) We present a generalized DP-based modeling framework for multi-machine systems integrated with IBRs that is capable of analyzing balanced and unbalanced conditions. 2) The model captures SSOs induced by GFL IBRs, shows reasonable agreement with EMT simulations, and demonstrates a significant speedup in a modified IEEE benchmark system. 3) We show that the time-invariance and linearizability of the framework can be leveraged to design a robust decentralized \mathcal{H}_{\infty} controller for damping the poorly-damped SSO mode using multiple IBRs as actuators. 4) We show that even when the SSO mode is well-damped, it can be excited by DC loads, and the locational impact of the DC load on the excitation can be predicted analytically. II Fundamentals of Dynamic Phasor The generalized averaging theory was first proposed in [ 11 ] , which suggests that a near-periodic (possibly complex) time-domain waveform x(\tau) in the interval \tau\in(t-T,t] can be expressed using a Fourier series of the form x(\tau)=\sum_{k=-\infty}^{\infty}X_{k}(t)e^{jk\omega_{s}\tau} , where \omega_{s}=\frac{2\pi}{T} , k\in\mathbb{Z} , and X_{k}(t) are the complex Fourier coefficients that vary with time as the window of width T slides over the signal. The k th coefficient, also known as the k th DP , can be calculated at time t by the following averaging operation X_{k}(t)=\frac{1}{T}\int_{t-T}^{t}x(\tau)e^{-jk\omega_{s}\tau}d\tau=\left\langle x\right\rangle_{k}(t) . In the DP framework, we are interested in a good approximation provided by the set \mathcal{U} of dominant Fourier coefficients such that x(\tau)\approx\sum_{k\in\mathcal{U}}\left\langle x\right\rangle_{k}(t)e^{jk\omega_{s}\tau} . Therefore, the generalized averaging-based method leads to an approximated model. From now on, we drop the time variable from DP notations for sake of simplicity. The following are some of the useful properties of DPs: (1) \left\langle\frac{\mathrm{d}x}{\mathrm{d}t}\right\rangle_{k}=\frac{\mathrm{d}\left\langle x\right\rangle_{k}}{\mathrm{d}t}+jk\omega_{s}\left\langle x\right\rangle_{k} ; (2) if x(\tau) is real, then \langle x\rangle_{k}=\langle x\rangle_{-k}^{*} ; and (3) in pnz frame, \langle x_{p}\rangle_{-k}=\langle x_{n}\rangle_{k}^{*} . Note that the time-domain waveform x(\tau) above can be abc phase quantities, asynchronous dq0 frame quantities, or synchronous DQ0 frame quantities (note the orientation of axes used in Fig. 1 ). Using the transformation in synchronously rotating reference frame, the relationship between DQ0 and pnz quantities can be obtained in terms of DPs. \begin{aligned} &\langle x_{D}\rangle_{k}=\frac{\langle x_{p}\rangle_{k+1}+\langle x_{n}\rangle_{k-1}}{\sqrt{2}};~\langle x_{Q}\rangle_{k}=-\frac{\langle x_{p}\rangle_{k+1}-\langle x_{n}\rangle_{k-1}}{\sqrt{2}j}\\ &\langle x_{p}\rangle_{k+1}=\frac{\langle x_{D}\rangle_{k}-j\langle x_{Q}\rangle_{k}}{\sqrt{2}};~~\langle x_{n}\rangle_{k-1}=\frac{\langle x_{D}\rangle_{k}+j\langle x_{Q}\rangle_{k}}{\sqrt{2}};~\langle x_{z}\rangle_{k}=\langle x_{0}\rangle_{k}\end{aligned} (1) The following equations describe the relationship between asynchronous dq frame quantities and pnz frame quantities \displaystyle\langle x_{d}\rangle_{k}=\frac{1}{\sqrt{2}j}\left(e^{j\delta}\langle x_{n}\rangle_{k-1}-e^{-j\delta}\langle x_{p}\rangle_{k+1}\right) (2) \displaystyle\langle x_{q}\rangle_{k}=\frac{1}{\sqrt{2}}\left(e^{j\delta}\langle x_{n}\rangle_{k-1}+e^{-j\delta}\langle x_{p}\rangle_{k+1}\right) where, \delta is the angle between the Q -axis and the d -axis. For further details on the fundamental concepts, please refer to [ 4 ] . Fig. 1: Proposed genralized DP-based modeling framework capable of analyzing balanced/unbalance conditions. III DP-based Modeling of Multi-Machine System Integrating IBRs III-A Proposed genralized DP-based modeling framework capable of analyzing balanced/unbalance conditions Our proposed framework is shown in Fig. 1 that has the following features. 1. IBR modeling in dq -frame: The controllers of IBRs are typically based on vector control in dq frame. Hence, it is logical to consider the dominant DP coefficients in the same dq -frame for the averaged model of IBR circuit and the controllers instead of representing them in another frame. Usually, zero sequence current is not allowed to pass through IBRs. Therefore, we choose the DP coefficients k=0 and k=\pm 2 that capture positive and negative sequence quantities, respectively. The dq frame associated with a GFL IBR is uniquely determined by its phase locked loop (PLL), whereas the dq frame for a grid-forming (GFM) IBR is determined by its power-frequency droop control [ 5 ] . 2. Network and SG modeling in pnz domain: Transmission lines, loads, and SGs are modeled in the pnz domain, wherein k=\pm 1 DPs should