Yichen Li a, Aleksey Bolotnikov b, Milind Diwan a, Jay Hyun Jo a, Steven Kettell a, Steven Linden b, Xin Qian a, Matteo Vicenzi a and Chao Zhang a a Physics Department, Brookhaven National Laboratory, Upton, NY 11973, USA b Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973, USA E-mail · 2026
Read A 260-Liter Test Stand for Liquid Argon R&D by Yichen Li a, Aleksey Bolotnikov b, Milind Diwan a, Jay Hyun Jo a, Steven Kettell a, Steven Linden b, Xin Qian a, Matteo Vicenzi a and Chao Zhang a a Physics Department, Brookhaven National Laboratory, Upton, NY 11973, USA b Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973, USA E-mail (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-20703.txt.
Introduction
Li and eight colleagues describe a 260-liter liquid argon test stand for detector research at BNL. The system cleans argon gas with pumpless flow: boil-off gas is cleaned, recondensed, and sent back by gravity without a pump. A purity monitor tracks electron lifetime firsthand, gauging charge loss from impurities. Under set terms, electron lifetime is 0.5 ms. The system enables rapid retry of detector parts in full cycles within 7 days. That fast turnaround, medium volume, and direct purity checks suit testing designs for large liquid argon time projection chamber experiments.
Catalog record
| CREATOR | Yichen Li a, Aleksey Bolotnikov b, Milind Diwan a, Jay Hyun Jo a, Steven Kettell a, Steven Linden b, Xin Qian a, Matteo Vicenzi a and Chao Zhang a a Physics Department, Brookhaven National Laboratory, Upton, NY 11973, USA b Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973, USA E-mail |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 32211 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.20703
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A 260-Liter Test Stand for Liquid Argon R&D Yichen Li a, Aleksey Bolotnikov b, Milind Diwan a, Jay Hyun Jo a, Steven Kettell a, Steven Linden b, Xin Qian a, Matteo Vicenzi a and Chao Zhang a a Physics Department, Brookhaven National Laboratory, Upton, NY 11973, USA b Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973, USA E-mail Abstract We describe the design and performance of a 260-liter liquid argon (LAr) cryogenic test stand for liquid argon detector research and development at BNL. The system uses gas-phase argon purification with continuous pump-free circulation, in which boil-off argon gas is purified, recondensed, and returned to the cryostat by gravity without a mechanical recirculation pump; it also incorporates an upgraded condenser that increases the effective thermal contact area by a factor of 13 relative to the previously developed 20-liter system reported perviously. A liquid argon purity monitor is installed to measure the electron lifetime directly in LAr, enabling quantitative characterization of charge attenuation due to electronegative impurities. Under the operating conditions reported here, the demonstrated electron lifetime is 0.5 ms. The system is designed to enable rapid iteration of detector components in complete operational cycles, including pump-down, leak verification, cryogenic fill, stable operation, and warm-up, which can be completed within 7 days. Such a fast turnaround time, together with the medium-scale liquid volume and direct purity diagnostics, makes the facility well suited for testing and refining detector designs in support of large liquid argon time projection chamber (LArTPC) experiments. keywords Liquid Argon;Purity;Electron Lifetime 1 Introduction Liquid argon detectors [ 11 ] achieve sub-ppb level purity using liquid recirculation systems with cryogenic pumps and high-capacity filters such in SBND, ICRAUS, and DUNE experiments [ 8 , 5 , 6 ] . While this approach has been successfully demonstrated at multi-ton and kiloton scales, it entails substantial infrastructure, including external purification units, continuous liquid pumping, and complex cryogenic services. Such systems are well suited for long-term detector operation; however, they are not optimized for rapid prototyping cycles in research and development (R&D) environments because of their high cost, the complexity of the associated cryogenic plumbing and pumping systems, and excessively large scale, which results in cooldown and warm-up cycles that can extend from weeks to months. At the opposite extreme, very small laboratory cryostats do not fully reproduce the thermal behavior, impurity dynamics, and mechanical integration challenges encountered in larger detector volumes. An intermediate-scale liquid argon platform that maintains realistic cryogenic and purity conditions while minimizing infrastructure complexity is therefore highly desirable for detector component development [ 4 , 7 , 9 ] . A previously developed 20-liter test stand at BNL demonstrated that the required high-purity of sub-ppb level impurity concentration can be achieved using gas-phase purification alone, without liquid recirculation pumps, by continuously purifying argon boil-off gas and returning condensed purified liquid to the main dewar [ 10 ] . That system allowed for pump-free circulation of small volumes, but purity characterization relied primarily on gas analyzers and indirect lifetime estimates, which limits its applicability for detector prototyping. To investigate a system with a larger applicable volume, we designed and constructed a 260-L system to demonstrate that gas-phase purification alone can sustain millisecond-scale electron lifetimes in a larger liquid argon volume suitable for medium-scale detector R&D, while preserving operational simplicity and rapid turnaround. The 260-L system relies on the pump-free circulation scheme while incorporating three key developments required for scaling. First, the condenser is redesigned as a multi-tube heat exchanger that increases the effective thermal exchange area by a factor of thirteen relative to the earlier 20-liter configuration, improving condensation efficiency and pressure stability. Second, a liquid argon purity monitor is installed to measure the electron lifetime directly in the liquid, providing a quantitative and application-relevant purity metric. Third, the system is explicitly engineered for rapid operational cycling; a complete cryogenic sequence, including vacuum pump-down, leak verification, cryogenic filling, stable operation, and warm-up, can be completed within 7 days. Together, these features establish a medium-scale liquid argon platform that combines realistic detector conditions with laboratory-kind flexibility. The system enables iterative development of high-voltage feedthroughs, field cage structures, charge readout configurations, photon detection systems, and material compatibility studies in support of large LArTPC experiments. Throughout this paper, purity is quantified primarily by the charge attenuation as it drifts through the liquid argon volume. This is encapsulated in the electron lifetime constant \tau (see Sec. 4.2 ) For meter-scale drift distances, a sub-ppb level impurities concentration level is required. This paper is organized as follows. Section 2 describes the cryogenic system and its components. Section 3 reports system operation and performance. Section 4 presents the purity monitor and electron lifetime measurements. Section 5 compares the 260-L system with the earlier 20-L system, and Section 6 provides a summary and discussion. 2 System Description 2.1 Cryogenic System Overview and Operation The cryogenic system is built around a vertical Multi-Layer Insulation (MLI) cryostat with a nominal capacity of 260 L. Fig. 1 shows a schematic representation of the system. The inner vessel is 22 inches in diameter and is sealed by a 27 inch top access WireSeal flange that supports multiple instrumentation and service feedthroughs. The cryostat has been pressure-tested to 30 psig and is administratively limited to a maximum allowable working pressure of 15 psig. The top flange accommodates feedthroughs for high-voltage, readout electronics, temperature and pressure sensors, liquid level instrumentation, and an optical feedthrough used for ultraviolet light delivery when operating electron sources or the purity monitor. (a) (b) Figure 1 : (a) Schematic of the 260-L system. The essential components are highlighted in red: main cryostat (1), purifier (7), condenser (8), and inline filter (3). The pump-free circulation path is shown by the red dashed line. (b) Photograph of the setup, with the main dewar on the left, the LAr supply dewar in the middle, and the LN2 supply dewar on the right. This new 260-liter system adopts the same cryogenic concept as the previously developed 20-liter system [ 10 ] , with significant scale-up by one order of magnitude. Compared to the 20-liter system, to ensure high-purity performance, all seals in the system were implemented as metal-to-metal connections, using VCR or Swagelok fittings, thereby avoiding joints that require Teflon tape, O-rings, or vacuum grease. The cooling relies on balancing the heat load into the liquid argon with the cooling power provided by condensing boil-off argon gas in a liquid nitrogen LN 2 -cooled heat exchanger. Heat leak into the cryostat vaporizes a fraction of the liquid argon, increasing the argon vapor pressure and driving a steady gas flow through the purifier cylinder and onward to the condenser. The condenser removes the latent heat of condensation from the argon gas using liquid nitrogen at a controlled saturation temperature, producing purified liquid argon that returns to the cryostat by gravity through insulated tubings. In steady state, the argon mass flow rate through the circulation loop is set by the system heat load and the effectiveness of the condenser, and the system circulates argon continuously without using a mechanical recirculation pump. This pump-free architecture removes a moving cryogenic component from the argon circulation and avoids the high cost, plumbing, controls, vibration, and maintenance associated with