Multilayer Laue Lenses for Enhanced Spatial Resolution in Dark-Field X-ray Microscopy Preprint: AIP/123-QED

S. Staeck, C. Yildirim, R. Rodriguez-Lamas, T. Dufrane, C. Detlefs, N. Gellert, A. Gayoso Padula, H. F. Poulsen · 2026

Read Multilayer Laue Lenses for Enhanced Spatial Resolution in Dark-Field X-ray Microscopy Preprint: AIP/123-QED by S. Staeck, C. Yildirim, R. Rodriguez-Lamas, T. Dufrane, C. Detlefs, N. Gellert, A. Gayoso Padula, H. F. Poulsen (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-20309.txt.

Introduction

Staeck and seven colleagues use crossed multilayer Laue lenses as the lens in dark-field X-ray microscopy. At ID03, two flat Mo-Si lenses with a 50 by 50 micron opening focus near 14 mm at 19 keV. Under a 10 percent transfer test, bright-field sharpness hits 56 nanometres, over three times sharper than a refractive lens, with dark-field sharpness close behind. The lens runs at 26.7 percent efficiency, with triple the light grasp of the refractive case, speeding direction maps and aiding tomography.

Catalog record

CREATORS. Staeck, C. Yildirim, R. Rodriguez-Lamas, T. Dufrane, C. Detlefs, N. Gellert, A. Gayoso Padula, H. F. Poulsen
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35276
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.20309

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Multilayer Laue Lenses for Enhanced Spatial Resolution in Dark-Field X-ray Microscopy Preprint: AIP/123-QED S. Staeck, C. Yildirim, R. Rodriguez-Lamas, T. Dufrane, C. Detlefs, N. Gellert, A. Gayoso Padula, H. F. Poulsen Abstract We introduce the use of a crossed pair of Multilayer Laue Lenses (MLLs) as an objective in Dark-Field X-ray Microscopy (DFXM). In a demonstration experiment at the ID03 beamline at ESRF, two flat Mo-Si MLLs were used, with a physical aperture of 50 × 50 µ ​ m 50\times$50\text{\,}\mathrm{\SIUnitSymbolMicro m}$ , and a focal length of 14.25 mm 14.25\text{\,}\mathrm{m}\mathrm{m} at 19.0 keV 19.0\text{\,}\mathrm{k}\mathrm{e}\mathrm{V} . Applying a 10 % criterion to the Modulation Transfer Functions (MTFs) acquired, a spatial resolution of 56 nm 56\text{\,}\mathrm{nm} is obtained in bright-field mode — more than three times better than with a compound refractive lens (CRL) objective. The dark-field resolution is similar. With an efficiency of 26.7 % the MLL objective expands the science domain of DFXM significantly, both for bulk and near-surface studies. Similar to the CRL case, the reciprocal space resolution is dominated by the numerical aperture (NA) of the objective, with the NA being three times larger in the MLL case. This enables faster orientation mapping and implies improved options for the use of tomographic reconstruction algorithms. Although the MLL objective pupil varies with energy and position, secondary peaks are suppressed, simplifying both interpretation and forward simulations. We present an example DFXM application using the MLL as objective, imaging a through-silicon via Kelvin device. Hard X-ray imaging is a key tool for non-destructive characterization of crystalline microstructures in bulk materials, providing access to grains, domains, strain fields, and defect structures deep inside engineering alloys, ceramics, rocks and functional devices 29 ; 16 ; 8 ; 19 ; 31 ; 6 . At photon energies above 15\text{\,}\mathrm{k}\mathrm{e}\mathrm{V} , diffraction-based contrast enables sensitivity to crystallographic orientation and elastic strain while retaining sufficient penetration depth for three-dimensional studies of embedded micro-structural features. Achieving high spatial resolution under these conditions is essential for resolving fine micro-structural length scales that ultimately govern macroscopic material properties. Dark-field X-ray microscopy (DFXM) is a full-field diffraction-based microscopy technique that addresses this need by forming a magnified real-space image from a selected Bragg-diffracted beam using an X-ray objective 36 ; 43 ; 28 . By varying the scattering vector, maps of local orientation and axial elastic strain can be obtained for a given Bragg reflection. The achievable spatial resolution in DFXM is ultimately determined by the X-ray objective lens. DFXM studies have so far employed compound refractive lenses (CRLs), fabricated from Be 37 ; 12 ; 15 ; 33 ; 30 , diamond 39 or SU-8 photo-resist 22 ; 7 . A spatial resolution of approximately 150\text{\,}\mathrm{nm} is typically achieved. Although the diffraction limit of Be CRLs can be significantly lower, under realistic experimental conditions lens figure errors and signal-to-noise considerations dominate the attainable resolution. Multilayer Laue lenses (MLLs) provide a route to overcoming this resolution limit. By exploiting Bragg diffraction in depth-graded multilayer structures, MLLs exhibit substantially higher numerical apertures than refractive optics while maintaining high diffraction efficiency and compatibility with photon energies well above 15\text{\,}\mathrm{k}\mathrm{e}\mathrm{V} 17 ; 41 ; 1 ; 11 . State-of-the-art MLLs have demonstrated 3\text{\,}\mathrm{nm} focusing in dedicated nanofocusing configurations 5 . MLLs can also be employed as objectives for full-field imaging, as demonstrated in bright-field mode for synchrotron based research 25 ; 24 ; 21 and more recently also for use with laboratory based X-ray sources 14 . While a first demonstration of MLL operation in a dark-field geometry has been reported for a single BaTiO 3 domain configuration 12 , no assessment of spatial resolution, contrast formation, comparison with CRL-based DFXM image contrast, or broader applicability has been carried out to date. In this letter, we address this gap by presenting a systematic study of a crossed pair of MLLs for DFXM use. With a fixed mount and a distance of 50\text{\,}\mathrm{\SIUnitSymbolMicro m} between the vertical and horizontal MLL, the pair effectively acts as a single 2D objective. We benchmark the intrinsic imaging performance of this objective using bright-field imaging and directly compare DFXM images acquired with MLL and CRL objectives under comparable conditions. The results demonstrate a clear improvement in DFXM spatial resolution beyond the practical limits of CRL objectives. The applied imaging system is illustrated in Fig. 1 in both bright-field and dark-field mode. The two identical 1D MLLs are oriented orthogonal to each other and used for imaging in the vertical and horizontal directions. For medium to large X-ray magnification \mathcal{M} the angular deviation between the incident beam and the first order diffracted beam, \theta_{c} , is sufficient that no order-defining aperture is needed. When \Delta\ll d_{1} (with distances defined in Fig. 1 ), the two MLLs have a joint focal length, f . In this case, \mathcal{M}=d_{2}/d_{1} , which, combined with the lens makers’ equation, leads to the relation d_{1}=(\mathcal{M}+1)/\mathcal{M}\;f . The MLL objective’s angular acceptance and aberrations preclude a thin-lens description. Following Yan et al. 41 volume diffraction effects can only be neglected if \omega<(2\Delta r_{min})^{2}/\lambda . Here \omega symbolizes the thickness of the MLL along the X-ray beam direction and \Delta r_{min} the width of the outermost zone. This inequality is not fulfilled for MLL designs of relevance to DFXM. Hence, the complex pupil (the apparent size of the lens aperture) for the first order diffraction is not fixed but varies with energy, across the aperture and as a function of the incidence angle of the beam in relation to the optical axis of the MLL. To simulate the microscope properties — and eventually DFXM images — one must as function of position calculate the fraction of the lens that satisfies the Bragg condition and take into account dynamical diffraction effects. Yan et al. provided a comprehensive theoretical description using a Takagi-Taupin description for flat and wedged MLLs. Several groups have shown that one may use ray tracing for forward simulations 10 . In particular, Chapman and Bajt used such simulations in conjunction with perturbation analysis to derive off-axis and chromatic aberrations in a focusing geometry 4 . The two identical flat MLLs were manufactured by sputtering subsequent layers of Mo, C, Si and C 10 . The detailed layout is provided in Supplementary material, section 1. The two MLLs are oriented orthogonal to each other with a fixed distance of \Delta=$50\text{\,}\mathrm{\SIUnitSymbolMicro m}$ . The combined unit has a physical aperture of 50\times$50\text{\,}\mathrm{\SIUnitSymbolMicro m}$ and a size of 28\times 20\times$16\text{\,}\mathrm{mm}$ . Once assembled, there are no internal degrees of freedom. Fig. 1 shows the basic set-up geometry. Figure 1: Imaging set-up. MLL v and MLL h enables imaging by Bragg diffraction in the vertical and horizontal directions, respectively. With a small gap between them, \Delta=$50\text{\,}\mathrm{\SIUnitSymbolMicro m}$ , the two act as one 2D lens objective. This may be exploited in bright-field (blue) or dark-field (orange) imaging mode. d_{1} and d_{2} symbolize the sample-objective and objective-detector distance, respectively. 2\theta is the scattering angle related to the diffracting element within the sample. \theta_{c} is the angle between the incoming beam and the optical axis of the objective. \mu describes the rocking direction motor, \chi the rolling direction motor. Adapted from Murray 21 . The experiment was carried out

Read the complete text