Laser-based mass spectrometry for the detection of signatures of life within our Solar System

Andreas Riedo \orcidID 0000-0001-9007-5791 and Salome Gruchola \orcidID 0000-0002-9757-1402 and Nikita J. Boeren \orcidID 0000-0001-6162-6953 and Peter Keresztes Schmidt \orcidID 0000-0002-4519-8861 and Luca N. Knecht \orcidID 0009-0007-2548-6501 and Youcef Sellam \orcidID 0009-0002-7690-5386 and Marek Tulej \orcidID 0000-0001-9823-6510 and Peter Wurz \orcidID 0000-0001-9823-6510 · 2026

Read Laser-based mass spectrometry for the detection of signatures of life within our Solar System by Andreas Riedo \orcidID 0000-0001-9007-5791 and Salome Gruchola \orcidID 0000-0002-9757-1402 and Nikita J. Boeren \orcidID 0000-0001-6162-6953 and Peter Keresztes Schmidt \orcidID 0000-0002-4519-8861 and Luca N. Knecht \orcidID 0009-0007-2548-6501 and Youcef Sellam \orcidID 0009-0002-7690-5386 and Marek Tulej \orcidID 0000-0001-9823-6510 and Peter Wurz \orcidID 0000-0001-9823-6510 (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-18749.txt.

Introduction

Riedo and seven colleagues review laser ionization mass spectrometry as a way to search for signs of life within our solar system. The method maps microstructures in complex rock hosts by chemical depth scans, reads sulphur isotope signatures, and finds varied organic molecules. The spectra can feed network and machine-learning routines for unbiased biosignature search. The authors call the technique novel and promising for future missions devoted to life detection.

Catalog record

CREATORAndreas Riedo \orcidID 0000-0001-9007-5791 and Salome Gruchola \orcidID 0000-0002-9757-1402 and Nikita J. Boeren \orcidID 0000-0001-6162-6953 and Peter Keresztes Schmidt \orcidID 0000-0002-4519-8861 and Luca N. Knecht \orcidID 0009-0007-2548-6501 and Youcef Sellam \orcidID 0009-0002-7690-5386 and Marek Tulej \orcidID 0000-0001-9823-6510 and Peter Wurz \orcidID 0000-0001-9823-6510
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE46597
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.18749

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Laser-based mass spectrometry for the detection of signatures of life within our Solar System Andreas Riedo \orcidID 0000-0001-9007-5791 and Salome Gruchola \orcidID 0000-0002-9757-1402 and Nikita J. Boeren \orcidID 0000-0001-6162-6953 and Peter Keresztes Schmidt \orcidID 0000-0002-4519-8861 and Luca N. Knecht \orcidID 0009-0007-2548-6501 and Youcef Sellam \orcidID 0009-0002-7690-5386 and Marek Tulej \orcidID 0000-0001-9823-6510 and Peter Wurz \orcidID 0000-0001-9823-6510 Abstract The search for signatures of life beyond Earth has been a major goal of space research and astrobiology for decades. The combination of expanded knowledge on Solar System bodies from past missions and advancements in in-situ detection technologies may place humanity on the verge of discovering extraterrestrial life. Here, we highlight the current measurement capabilities of Laser Ionisation Mass Spectrometry for the detection of several classes of signatures of life of high relevance to current astrobiology-focused missions. This includes the detection of microstructures within complex geological hosts by chemical depth profiling, sulphur isotope fractionation signatures, and the detection of various classes of organic molecules. The recorded mass spectrometric data can be fed into network and machine learning analysis routines, which are powerful tools for the unbiased detection of signatures of life, including agnostic detection of biosignatures. We demonstrate that Laser Ionisation Mass Spectrometry is a novel and promising technology for future application on space exploration missions devoted to life detection. 1 Introduction Mass spectrometry is one of the most sensitive and analytically most specific technique for the chemical composition analysis of any solid. As a result, mass spectrometers are typically part of the instrument payload on space exploration missions, either for in-situ chemical analyses of a planetary atmosphere or on the planetary surface to search for signatures of life. The latter dates back to the 1970s, when mankind sent the two Viking landers to the surface of Mars ( 64 ) to detect signatures of life using Gas Chromatography-Mass Spectrometry (GC-MS) ( 46 ) , unfortunately without providing conclusive evidence for the presence of extinct or extant life. GC-MS instrumentation for space exploration has been continuously further developed in terms of measurement capabilities, and one of the most sophisticated GC-MS systems is the Sample Analysis at Mars (SAM) instrument ( 37 ) , which is part of NASA’s Curiosity rover on Mars ( 22 ) . Although GC-MS instruments belong to the state-of-the-art equipment in laboratory research, they experienced limitations when applied on planetary surfaces, e.g., in the presence of chlorinated species ( 56 ) . In this chapter, we review the current measurement capabilities of two Laser Ionisation Mass Spectrometry (LIMS) systems developed in-house and applied to the detection and identification of signatures of life. Previously we have shown that LIMS has the potential to identify micrometre-scale features within a complex geological host ( 65 ; 62 ) , to provide isotope ratio measurements with per mille accuracy in delta notation to identify possible fractionation processes ( 48 ) , and to detect organic molecules important for life as we know it, including amino acids ( 30 ) , lipids ( 7 ) , and nucleobases ( 8 ) , at surface concentrations down to \mathrm{fmol}\text{\,}{\mathrm{mm}}^{-2} . The latter is of great interest for current space science, as the mass spectrometric system already fulfils many measurement requirements, e.g., for a landed mission on Enceladus ( 36 ) or Europa ( 24 ) . The NCCR PlanetS allowed to extend and better understand the measurement capabilities of one of the LIMS systems, which is specifically designed and used for the detection and identification of organic molecules. Initially, studies were conducted solely on amino acids. Thanks to NCCR PlanetS, in-depth studies of lipids and nucleobases were made possible, opening new doors in this competitive field of space science. 2 Laser Ionisation Mass Spectrometry For more than two decades, the laser mass spectrometry group at the University of Bern has been developing and further optimising LIMS systems ( 54 ; 47 ; 69 ) and new measurement methodologies for the chemical composition analysis of various samples of interest ( 8 ; 45 ; 68 ; 18 ; 21 ) . In the following, we briefly describe the schematics (Fig. 1 ) and operating principles of two of our miniature LIMS space prototype systems. We specifically apply these instruments to develop new measurement protocols for the detection of life signatures presented in this contribution ( 48 ; 23 ; 49 ) . t] Figure 1: Schematics and operating principles of our miniature LIMS setups. The two LIMS systems both consist of the same core component, a reflectron-type time-of-flight (RTOF) mass analyser ( 160\text{\,}\mathrm{mm} x Ø 60\text{\,}\mathrm{mm} ), which can be coupled to various laser ablation or laser desorption ion sources (from femtosecond pulsed laser systems operating at 775\text{\,}\mathrm{nm} down to 258\text{\,}\mathrm{nm} , to nanosecond pulsed laser systems typically operating at 266\text{\,}\mathrm{nm} ). The main difference between these two modes of operation is the laser irradiance applied onto the sample surface. For element and isotope composition analyses, laser ablation conditions are required with laser irradiances in the {10}^{9}\text{\,}\mathrm{W}\text{\,}{\mathrm{cm}}^{-2} to {10}^{12}\text{\,}\mathrm{W}\text{\,}{\mathrm{cm}}^{-2} range (ns to fs laser pulses), resulting in efficient removal and atomisation of material from a solid with each laser pulse fired. For the detection of organic molecules, laser irradiances at the level of {10}^{6}\text{\,}\mathrm{W}\text{\,}{\mathrm{cm}}^{-2} have to be applied, which allow for the gentle removal and ionisation of molecules from the surface without severe fragmentation, if any. We typically have one LIMS system operating under ablation conditions (referred to as the Laser Mass Spectrometer (LMS) ( 62 ; 51 ) ) and one system operating under desorption conditions (referred to as ORganics Information Gathering INstrument (ORIGIN) ( 8 ) ). In both LIMS setups, the laser system and beam delivery optics are located outside a vacuum chamber for simplicity, while the mass analyser is operated inside a vacuum chamber. A lens system focusses the laser beam through the mass analyser’s central axis onto the sample surface to spot sizes ranging from about 10\text{\,}\mathrm{\SIUnitSymbolMicro m}30\text{\,}\mathrm{\SIUnitSymbolMicro m} in diameter. A larger spot size is preferred for laser desorption studies, as it reduces the laser irradiances, while for laser ablation studies a smaller spot size allows for higher spatial resolution. The sample of interest is placed close to the entrance of the ion optical system of the mass analyser, typically within mm-range. For each laser pulse-material interaction, a distinct layer of sample material is removed and partially ionised. The positively charged ions can enter the ion optical system of the mass analyser, where they are confined and accelerated towards the field-free drift tube. The species are then redirected by the reflectron towards the detector system ( 52 ) by passing through the drift tube a second time. The ions arrive at the detector system sequentially according to their mass-to-charge ratio ( 5 ) . Read-out electronics are used to record the electrical signal generated by the detector system. We typically record the detector signal up to 20\text{\,}\mathrm{\SIUnitSymbolMicro s} after the laser pulse hits the surface, resulting in the TOF spectrum covering up to about m/z 700. 2.1 Measurement Procedures The measurement procedure depends on the scientific question and the sample under investigation. Therefore, there is no typical LIMS measurement routine that we follow one to one. Although the measurement protocols

Read the complete text