Read Rethinking Cross-Dose PET Denoising: Mitigating Averaging Effects via Residual Noise Learning by Yichao Liu, Zongru Shao, Yueyang Teng, Junwen Guo (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-16925.txt.

Introduction

Liu and three colleagues challenge one-size-fits-all denoising for low-dose PET scans. A single model averages across dose levels and blurs dose-specific noise. Their residual approach learns the noise directly from low-dose images instead of predicting clean images, outperforming single-dose and dose-conditioned models on multi-dose data from two medical centers.

Catalog record

CREATORYichao Liu, Zongru Shao, Yueyang Teng, Junwen Guo
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE29785
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.16925

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Rethinking Cross-Dose PET Denoising: Mitigating Averaging Effects via Residual Noise Learning Yichao Liu, Zongru Shao, Yueyang Teng, Junwen Guo Abstract Cross-dose denoising for low-dose positron emission tomography (LDPET) has been proposed to address the limited generalization of models trained at a single noise level. In practice, neural networks trained on a specific dose level often fail to generalize to other dose conditions due to variations in noise magnitude and statistical properties. Conventional “one-size-for-all” models attempt to handle this variability but tend to learn averaged representations across noise levels, resulting in degraded performance. In this work, we analyze this limitation and show that standard training formulations implicitly optimize an expectation over heterogeneous noise distributions. To this end, we propose a unified residual noise learning framework that estimates noise directly from low-dose PET images rather than predicting full-dose images. Experiments on large-scale multi-dose PET datasets from two medical centers demonstrate that the proposed method outperforms the “one-size-for-all” model, individual dose-specific U-Net models, and dose-conditioned approaches, achieving improved denoising performance. These results indicate that residual noise learning effectively mitigates the averaging effect and enhances generalization for cross-dose PET denoising. I Introduction Positron emission tomography (PET) plays a central role in oncologic staging [ 8 , 11 ] , therapy response assessment [ 15 , 10 ] , and longitudinal disease monitoring [ 12 , 19 ] . However, PET image quality is intrinsically constrained by limited photon counts, which are dictated by injected dose and acquisition time [ 23 ] . Dose reduction is clinically desirable to minimize radiation exposure, particularly in vulnerable populations and longitudinal studies, yet reduced counts induce severe Poisson noise, contrast degradation, and quantification bias in standardized uptake value (SUV) measurements [ 24 , 20 , 29 ] . These effects compromise lesion detectability and downstream clinical decision-making. Traditional method, such as iterative reconstruction algorithms and post-reconstruction filtering techniques, have historically proven their effectiveness in the low-dose PET images denoising [ 16 , 4 , 21 , 9 ] . However, those methods are either time-consuming or prone to producing over-smoothed results that compromise fine structural details. Recently, deep learning (DL) has emerged as a superior alternative to conventional iterative reconstruction and post-reconstruction filtering for PET image denoising [ 6 , 22 ] . Convolutional neural networks (CNNs), in particular, have been extensively explored across several research directions. To improve feature representation, Xiang et al. [ 26 ] introduced a deep auto-context CNN that iteratively refines predictions to maintain image quality at lower radiation doses. Addressing resolution loss, Spuhler et al. [ 22 ] developed a dilated CNN (dNet) that expands the network’s receptive field without the need for downsampling. Beyond single-modality approaches, joint filtering frameworks have been proposed to denoise dynamic PET data by leveraging anatomical guidance from high-resolution MRI [ 7 ] . More recently, research has shifted toward task-specific optimization, such as the LeqMod strategy, which utilizes downstream lesion quantification to ensure clinical accuracy in denoised images [ 25 ] . Beyond standard CNNs, Generative Adversarial Networks (GANs) have been extensively adapted for low-dose PET denoising to better preserve high-frequency details. For instance, Ouyang et al. [ 17 ] utilized feature matching and task-specific perceptual loss to synthesize standard-dose amyloid PET images from ultra-low-dose data (1% counts). To enhance training stability and quantitative fidelity, Zhou et al. [ 32 ] introduced CycleWGANs, which integrates cycle-consistency with the Wasserstein distance metric. More recently, the focus has shifted toward model robustness; Xue et al. [ 28 ] developed a GAN-based approach for cross-scanner and cross-tracer recovery, demonstrating that a model trained on FDG-PET can successfully generalize to other tracers and hardware without retraining. Despite these advancements, they face a critical limitation: models trained on a specific noise level often fail to generalize well across diverse acquisition conditions. This performance degradation is caused by domain shift, the difference in joint probability between training and testing data, resulting in inaccurate estimations when there is a mismatch in count levels [ 27 ] . While training a ”one-size-fits-all” model for cross-dose denoising may seem like a straightforward remedy, such models typically develop a bias toward the high-noise end of the spectrum, ultimately compromising their performance [ 13 ] . Fig. 1: Noise analysis for 1/100 noise level and 1/2 noise level LDPET images. Noise image is calculated by the difference between FDPET and LDPET. Fig. 2: The overview of the training network. The model takes a LDPET image as input and predicts the underlying noise. To prevent the loss of negative noise components, standard ReLU activations within the U-Net are replaced with LeakyReLU activation function. During training, the final denoised PET prediction is processed via a LeakyReLU with a shallow slope 0.01 to prevent neuron death. During inference, the model reverts to ReLU activations for the final output to ensure non-negative PET values. To address the challenges of varying count statistics, unified models have been proposed to facilitate cross-dose level denoising. The Unified Noise-Aware Network (UNN) was introduced to adaptively merge multiple specialized denoising subnetworks through a learned weighting mechanism, achieving robust PET image quality across diverse and unknown photon count levels [ 27 ] . Building on this framework, the ST-UNN architecture replaces traditional convolutional layers with Swin Transformer blocks and increases subnetwork granularity to eight levels, specifically targeting the complexities of ultra-low-dose PET imaging (below 10% count) [ 1 ] . However, the UNN-based approach is computationally intensive, as it necessitates the simultaneous training and storage of multiple specialized subnetworks. To improve efficiency, an alternative approach utilizing Continuous Adversarial Domain Generalization (CADG) employs a single model with a continuous discriminator in the feature space [ 14 ] . This framework enforces the extraction of noise-level invariant features, enabling the network to generalize effectively across arbitrary and unseen PET count levels. A potential drawback of such domain generalization is that enforced domain invariance can inadvertently degrade performance in scenarios where the domain and label are entangled [ 5 , 31 ] . While the authors of the CADG study argue that PET denoising primarily involves covariate shift, where the full-count label distribution remains consistent regardless of the noise level, this assumption may not hold in broader clinical practice. Nevertheless, to the best of our knowledge, no existing studies have explicitly identified that cross-dose training essentially forces the model to minimize an expectation loss across varying noise distributions. In this work, we first analyze the challenges inherent to cross-dose PET denoising, with a particular focus on the ’average learning’ effect. Second, we propose a solution centered on residual noise learning; as established by DnCNN [ 30 ] , this architecture facilitates faster convergence and superior training stability by focusing the network’s learning capacity on the noise distribution. Third, we validate our approach through experiments on two clinical datasets, demonstrating that our method achieves superior performance and high robustness across diverse patient cohorts. II Methods II-A Averaging effect of supervised cross-dose denoising In PET denoising, given a low-dose image \mathbf{x}\in\mathcal{R}^{H\times W} , the corresponding full-dose image \mathbf{y}\in\mathcal{R}^{H\times W} , where W and H are width and height, and f_{\theta} is denoising network, the denoising process can be formulated as: arg\,\underset{\theta}{min}\sum_{i}L(f_{\theta}(\mathbf{x}_{i}),\mathbf{y}_{i}) (1) Here, L is the loss function. \theta is the network parameter.

Read the complete text