RFID-based Real-Time Geriatric Gait Speed Monitoring System: Design, Implementation and Clinical Evaluation

Natong Lin 1 , Jiachen Wang 1 , Lisa C. Barry 2 , Song Han 1 · 2026

Read RFID-based Real-Time Geriatric Gait Speed Monitoring System: Design, Implementation and Clinical Evaluation by Natong Lin 1 , Jiachen Wang 1 , Lisa C. Barry 2 , Song Han 1 (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-14023.txt.

Introduction

Lin and colleagues monitor walking speed with a fully passive, battery-free RFID system, replacing stopwatch timing in clinics. A dual-antenna setup plus an edge peak-detection algorithm reads signal-strength streams in real time, using antenna-beam symmetry to resist noise and plateaus. Across 966 trials at three clinics, the system succeeds in 87.7 percent of measurements, with mean error under a tenth of a metre per second.

Catalog record

CREATORNatong Lin 1 , Jiachen Wang 1 , Lisa C. Barry 2 , Song Han 1
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE56070
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.14023

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

RFID-based Real-Time Geriatric Gait Speed Monitoring System: Design, Implementation and Clinical Evaluation Natong Lin 1 , Jiachen Wang 1 , Lisa C. Barry 2 , Song Han 1 Abstract Gait speed is a widely used indicator of functional health and mobility decline, yet in clinical practice it is commonly measured manually using a stopwatch, which limits scalability and measurement frequency. Privacy-preserving and maintenance-free sensing approaches can enable more routine and less burdensome assessments in real-world care settings. This paper presents the design, implementation, and real-world deployment of a fully passive, battery-free gait-speed monitoring system based on ultra-high-frequency (UHF) RFID. Compared with camera- and wearable-based approaches, the proposed system preserves patient privacy by avoiding video capture and biometric data, while eliminating battery maintenance. The system employs a dual-antenna configuration and an edge-based peak-detection algorithm to estimate gait speed in real time from received signal strength indicator (RSSI) streams. By leveraging antenna-beam symmetry and asymmetric signal processing, the method improves robustness to noise, plateau regions, and multiple local maxima. We evaluate the system during routine outpatient care across three clinical sites using 966 trials, achieving an 87.7% measurement success rate. Compared with concurrent stopwatch timing, the system attains a mean absolute error of 0.064 m / s m/s , demonstrating reliable operation with accuracy suitable for clinical gait-speed assessment. I Introduction Gait speed is a simple yet powerful indicator of functional health and mobility decline. In older adults, gait speed is strongly associated with survival, functional status, and self-rated health, and has been shown to provide reliable and valid assessment across different walking distances and pacing conditions [ 25 , 35 ] . Despite its clinical value, gait speed is often measured manually using stopwatch timing, which requires staff attention and typically occurs only during scheduled visits. This limits measurement frequency and may fail to capture typical performance, as patients often walk differently when formally observed than during routine clinical activities. To reduce manual burden and enable more scalable monitoring, many automated gait measurement systems have been proposed [ 24 ] . Camera-based systems can estimate gait parameters with high accuracy, but they raise privacy concerns and typically require carefully controlled placement [ 34 , 22 ] . Wearable-based approaches reduce environmental dependencies but impose burdens related to battery charging, device management, and user compliance [ 27 ] . Other modalities, such as radar, ultra-wideband (UWB), Bluetooth, and WiFi sensing, have also been explored; however, they often require specialized hardware or site-specific calibration—factors that can limit deployment in routine care settings [ 11 , 32 , 38 ] . Passive ultra-high-frequency (UHF) RFID provides an attractive alternative that aligns well with clinical deployment constraints. Passive RFID tags are battery-free, low-cost, and already common in healthcare environments for identification and tracking, while preserving privacy by avoiding video capture or biometric recording. Our team previously demonstrated the clinical feasibility of passive RFID for gait speed measurement, showing high agreement with manual stopwatch timing and strong acceptance from both patients and providers [ 2 ] . More recently, we showed that RFID-based gait speed assessment can be integrated into Medicare Annual Wellness Visit workflows across multiple primary care practices with high implementation fidelity following workflow and system refinements [ 3 ] . However, neither study addressed the underlying system design or signal-processing methodology. The earlier work validated clinical acceptability using manual timing as a reference, while the latter focused on workflow adoption rather than the technical architecture enabling real-time, automated measurement. This paper fills that technical gap by presenting a complete system architecture for passive RFID-based gait speed monitoring, including hardware configuration, real-time signal processing, and multi-site clinical deployment. Realizing this system for real-time clinical use presents several technical challenges across the signal, system, and deployment levels. At the signal level , RSSI measurements from passive tags are inherently noisy and often exhibit plateau regions near peak signal strength as tags pass close to antennas. In addition, RFID readers stream tag reads continuously without signaling when walking events begin or end, and patients may enter, pause, or restart walking attempts unpredictably. These characteristics make simple threshold-based triggering and offline peak selection unreliable for real-time operation. At the system level , the architecture must process high-rate streaming data with low latency and deliver immediate feedback to clinical staff through a responsive interface. At the deployment level , hardware selection and physical installation must accommodate diverse hallway configurations, varying patient heights, and existing clinical infrastructure across sites, using components that are cost-effective and maintainable without specialized technical support. We address these challenges through three integrated design decisions: (i) a dual-antenna, edge-based peak-detection algorithm that exploits antenna beam symmetry to detect consistent edge events rather than ambiguous plateau midpoints, resolving multiple-peak and unknown-termination challenges in streaming RSSI data; (ii) a Go-based backend that processes tag reads online and pushes results immediately to a browser-based clinical interface via WebSocket, eliminating manual timing and enabling real-time feedback; and (iii) a hardware configuration built entirely from commercial off-the-shelf RFID components with configurable antenna spacing to support installation across diverse clinical sites. We validate the system through deployment across three outpatient clinical sites, collecting 966 gait-speed trials during routine care. Across all sites, 87.7% of trials (847 of 966) produce valid measurements. In a separate comparison against concurrent stopwatch timing, the system achieves a mean absolute error of 0.064 m/s confirming accuracy sufficient for clinical gait speed assessment. All data collection was conducted under institutional review board approval (UConn Health IRB 25-1890-2). The remainder of this paper is organized as follows. Section II reviews related work on automated gait measurement systems. Section III describes the proposed RFID-based system, including the hardware configuration and software architecture. Section IV presents the real-time, dual-antenna peak-detection algorithm. Section V reports results from multi-site clinical deployment and evaluation. Section VI concludes the paper and points out the future directions. II Related Work Despite the established clinical value of gait speed as an indicator of functional health, mobility decline, and mortality risk in older adults [ 25 , 35 ] , accurately measuring gait in real-world settings presents significant technical challenges. Numerous gait measurement technologies have been developed [ 24 ] , employing diverse sensing modalities and signal processing techniques to capture gait parameters. These technologies span a broad spectrum, ranging from contact-based force sensors and wearable devices to non-contact approaches based on computer vision, radio-frequency sensing, and passive infrared detection. This section examines the technical characteristics of existing gait measurement approaches, including their measurement accuracy and their capabilities for real-time, automated processing to support integration into clinical workflows. Pressure-sensitive walkway systems are among the most widely deployed automated gait measurement technologies in clinical and research settings and have been shown to provide highly accurate and reliable spatiotemporal gait measurements. The GAITRite system employs a pressure-sensitive sensor array to capture spatial and temporal gait parameters with high precision [ 23 ] and has been validated in large-scale clinical studies [ 6 ] . Protokinetics ZenoMat walkways are also widely used in research and are commonly treated as a standard reference in gait analysis studies [ 5 , 20 , 28 ] . Similarly, pressure-sensitive mats such as the Tekscan HR Mat have been used in combination with wireless

Read the complete text