Read Bicuspid Valve Closure and Backflow Prevention: Role of Leaflet Geometry by B. Kaoui, A. Bou Orm, P. Navet, J. Baish, L.L. Munn (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-11776.txt.
Introduction
Kaoui and four colleagues test how leaflet length affects bicuspid efficiency against reflux. Crescent leaflets in lymphatic vessels and veins stop reflux and ensure unidirectional flow to the heart. Passive valves work from interplay between leaflet traits and flow. Under backward gravity-like flow, flux through the orifice is reported versus valve length, leaflet length, and rigidity. Varying leaflet length alone drives a transition from reflux to blockage, with threshold set by valve shape and stiffness. The study explains reflux in incompetent immature valves, especially short-leaflet ones.
Catalog record
| CREATOR | B. Kaoui, A. Bou Orm, P. Navet, J. Baish, L.L. Munn |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 43617 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2604.11776
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Bicuspid Valve Closure and Backflow Prevention: Role of Leaflet Geometry B. Kaoui, A. Bou Orm, P. Navet, J. Baish, L.L. Munn Abstract Bicuspid valves with crescent-shaped leaflets are found in lymphatic vessels and veins, where their primary function is to prevent reflux and ensure unidirectional flow toward the heart. These valves are passive, and their functionality emerges spontaneously from a complex interplay between the properties of the valve leaflets and the flow patterns developing within the vessel sinus region surrounding the valve. The main function of the valves is to limit retrograde flow, or reflux, but the optimal valve structure has not been well-characterized. Here we investigate numerically how the length of the leaflets affects the valve efficiency in preventing reflux. The valves are subjected to backward flow, akin to that imposed by gravity. We report the flux through the valve orifice as a function of key parameters: valve length, leaflet length, and leaflet rigidity. We monitor the transition in the flow regime - from reflux to complete flow blockage - by varying only the leaflet length. The transition threshold is found to depend strongly on the valve shape and stiffness. We captured these control parameters numerically to evaluate the ability of the valve to close and prevent reflux. This study allowed us to explain reflux observed experimentally in certain incompetent abnormal and immature valves, particularly those with shorter leaflets. I Introduction The lymphatic system consists mainly of a ramified network of lymphatic vessels (lymphatics), where lymph fluid is drained from the interstitial tissue by the initial lymphatic capillaries, transported by larger collecting lymphatic vessels, filtered by lymph nodes, and then re-injected back into the thoracic duct and the subclavian veins to reintegrate with the blood circulation Padera2016 ; Scallan2016 ; Moore2018 . Other organs, in addition to the vessels, are part of the lymphatic system, such as the lymph nodes, the thymus and spleen. While the heart serves as the central pump that pushes blood throughout the cardiovascular system, pumping in the lymphatic system is achieved locally at the level of the lymphangion, the vessel segment delimited by two flanking valves. What is intriguing about this process is the presence of a series of valves along the vessels that guarantee unidirectional flow. Each valve opens to allow forward flow, toward the heart, and closes to prevent retrograde flow. This occurs spontaneously without any external control Kunert2015 ; Munn2015 ; Baish2016 . Biological valves, including lymphatic and venous valves, are passive structures by default. They deform and adapt their configuration in response to the surrounding flow and vessel deformation. The objective of our present study is to examine the details of the closure mechanisms of bicuspid valves, which are composed of two crescent-shaped leaflets, as found in the lymphatics and blood veins, when subjected to backward flow. We aim to extend and complement previous studies that address the open question: What determines the efficiency of bicuspid valve closure during retrograde flow? In the present study, we investigate this question with a specific focus: How do leaflet mechanics and geometry affect closure efficiency? We address this question for valves of various lengths, and stiffness. To the best of our knowledge, this aspect is being explored for the first time. In this work we address an open question in biology and evolution by combining multiphysics simulations with a physics-based approach to analyze fluid–structure interactions and valve mechanics. In particular, we investigate a fundamental and still unresolved question: Why has nature produced valve leaflets with a crescent shape? Several aspects of valve geometry have already been treated in the literature. The effects of valve length and stiffness are relatively well understood: increasing valve length amplifies hydrodynamic resistance, while excessive stiffness hinders proper valve closure. However, a crucial question remains largely unexplored and is highly intriguing from both a biological and physical perspective: Why is the leaflet crescent-shaped, and to what extent should the valve leaflet be creased or curved to achieve optimal performance? In other words, What is the functional role of the cusp geometry beyond simple valve length and stiffness considerations? Most experimental studies on lymphatic vessels are biology oriented. Few studies have addressed the challenging in vivo and in vitro details of the fluid mechanics of the problem, and how fluid forces interplay with the valve mechanics, which is of interest to us. The most relevant study is by Munger et al. , who investigated the molecular mechanisms underlying lymphatic valve development Munger2017 and its effect on valve leaflet length, and thus, on the overall valve function. They have examined the effect of Connexin43 (Cx43), which is an essential protein for gap junctions between lymphatic endothelial cells. The authors used genetically modified mice to assess the consequences of Cx43-specific deletion in the lymphatic system and its role in lymphatic valve development and function. They demonstrated that Cx43 deletion in endothelial cells severely impairs valve development, resulting in the overall inability of the valves to prevent reflux. As a result, this disruption can give rise to pathologies such as chylothorax. On a molecular level, the study identifies Cx43 as a critical component for cell signaling and coordination among lymphatic endothelial cells. The results reveal a reduced number of functional valves in mutant mice, exhibiting structural disorganization and defects in morphogenesis, primarily manifesting as valves with short, underdeveloped leaflets that fail to achieve unidirectional flow. Another recently published work presents high-quality 3D images of developing lymphatic valves by categorizing valvulogenesis into four distinct stages Davis2024 . Each stage is defined by the growth and extension of the valve leaflets within the vessel. At early stages of development, when the leaflet starts taking shape, they are not able to prevent reflux. It is not until later stages of development that the mature valve acquires fully developed, long leaflets that can block reflux efficiently. Computer simulations are used to gain a deeper understanding of the details of valve function and lymphatic vessels, which are not accessible through in vivo , or even in vitro experiments Padera2016 ; Moore2018 ; Margaris2012 . Only a limited number have analyzed valve dynamics systematically using three-dimensional simulations Watson2017 ; Wilson2015 ; Wilson2018 ; Bertram2020 ; Bertram2023 ; Ballard2018 ; Wolf2021 . The most relevant to our study is by Ballard et al. Ballard2018 , who studied the effect of lymphatic valve overall length on its dynamic behavior and function. Their simulations focused on the effect of valve length and bending rigidity on valve efficiency. The results indicate that, for valves of given elasticity, the overall valve length should be short to optimize forward flow, but long to prevent backflow. Indeed, morphological abnormalities or excessive valve rigidity result in inefficient reflux blockage, which is characteristic of pathological conditions. The study also highlights mechanisms that may explain valve malfunctions observed in certain pathologies, such as lymphedema, where valves exhibit excessive rigidity or deformability. Although their simulations were also conducted in a straight, rigid vessel, similar to our setup, they did not investigate the role of leaflet length, which is a central focus of the present work. The authors developed a model based on a coupled fluid-structure approach. Flow dynamics of the lymph were computed using the Lattice Boltzmann Method (LBM) Succi2001