ConvFormer3D-TAP: Phase/Uncertainty-Aware Front-End Fusion for Cine CMR View Classification Pipelines

Nafiseh Ghaffar Nia, Vinesh Appadurai, Suchithra V., Chinmay Rane, Daniel Pittman, James Carr, and Adrienne Kline Center for Artificial Intelligence, Bluhm Cardiovascular Institute, Northwestern Medicine, Chicago, IL, USA Department of Electrical and Computer Engineering, Northwestern University, Chicago, IL, USA Department of Surgery, Northwestern University, Chicago, IL, USA Department of Radiology, Northwestern University, Chicago, IL, USA; and Xtasis Inc., Chicago, IL, USA Department of Cardiology, The Prince Charles Hospital; and School of Medicine, The University of Queensland, Queensland, Australia Quantiphi Inc., USA Corresponding author: [email protected] · 2026

Read ConvFormer3D-TAP: Phase/Uncertainty-Aware Front-End Fusion for Cine CMR View Classification Pipelines by Nafiseh Ghaffar Nia, Vinesh Appadurai, Suchithra V., Chinmay Rane, Daniel Pittman, James Carr, and Adrienne Kline Center for Artificial Intelligence, Bluhm Cardiovascular Institute, Northwestern Medicine, Chicago, IL, USA Department of Electrical and Computer Engineering, Northwestern University, Chicago, IL, USA Department of Surgery, Northwestern University, Chicago, IL, USA Department of Radiology, Northwestern University, Chicago, IL, USA; and Xtasis Inc., Chicago, IL, USA Department of Cardiology, The Prince Charles Hospital; and School of Medicine, The University of Queensland, Queensland, Australia Quantiphi Inc., USA Corresponding author: [email protected] (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-11389.txt.

Description

Ghaffar Nia and six colleagues classify standard cine cardiac MRI views with ConvFormer3D-TAP. The model joins 3D convolutional tokens with multiscale self-attention. It is trained with masked space-time rebuilding and uncertainty-weighted clip fusion, which helps it handle phase variation and ambiguous segments. On 150,974 clinic cine sequences across six standard views, it reached 96 percent validation accuracy with per-class F1 scores at or above 0.94 and strong calibration. Remaining errors cluster in neighboring long-axis and outflow view pairs, reflecting prescription overlap.

Catalog record

CREATORNafiseh Ghaffar Nia, Vinesh Appadurai, Suchithra V., Chinmay Rane, Daniel Pittman, James Carr, and Adrienne Kline Center for Artificial Intelligence, Bluhm Cardiovascular Institute, Northwestern Medicine, Chicago, IL, USA Department of Electrical and Computer Engineering, Northwestern University, Chicago, IL, USA Department of Surgery, Northwestern University, Chicago, IL, USA Department of Radiology, Northwestern University, Chicago, IL, USA; and Xtasis Inc., Chicago, IL, USA Department of Cardiology, The Prince Charles Hospital; and School of Medicine, The University of Queensland, Queensland, Australia Quantiphi Inc., USA Corresponding author: [email protected]
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE47355
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.11389

Browse the full library · About the Tower of Babel