Noise budget of Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS)

Mario Juvenal S. Onglao III, Hsiang-Yu Huang, Yuki Inoue, Vivek Kumar, Daiki Tanabe · 2026

Read Noise budget of Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS) by Mario Juvenal S. Onglao III, Hsiang-Yu Huang, Yuki Inoue, Vivek Kumar, Daiki Tanabe (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2604-05840.txt.

Introduction

Onglao and four colleagues budget noise for CHRONOS, a proposed sub-hertz gravitational-wave detector spanning 0.1 to 10 hertz. Cryogenics, cross torsion bars, a triangular Sagnac interferometer, and speed-meter readout target strain sensitivity near 10 to the power -18 per root hertz at 2 hertz. Simulations show competitive low-frequency sensitivity, plus possible earthquake early warning faster by about 3 to 7 seconds within 40 kilometers.

Catalog record

CREATORMario Juvenal S. Onglao III, Hsiang-Yu Huang, Yuki Inoue, Vivek Kumar, Daiki Tanabe
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE13806
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2604.05840

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Noise budget of Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS) Mario Juvenal S. Onglao III, Hsiang-Yu Huang, Yuki Inoue, Vivek Kumar, Daiki Tanabe Abstract CHRONOS is a proposed gravitational-wave detector designed to operate in the sub-Hz frequency (0.1–10 Hz) band, a largely unexplored range due to strong noise sources that hamper ground-based detectors. It employs cryogenic operation, cross torsion-bar configuration, triangular Sagnac interferometer, and speed meter readout scheme to overcome key noise limitations, targeting a strain sensitivity of h ∼ 10 − 18 Hz − 1 / 2 h\sim 10^{-18}\,\mathrm{Hz^{-1/2}} around 2 ​ Hz 2\,\mathrm{Hz} and a stochastic gravitational wave background of Ω G ​ W ∼ 2 × 10 − 3 \Omega_{GW}\sim 2\times 10^{-3} at 2 ​ Hz 2\,\mathrm{Hz} . Using analytical and interferometric simulations with FINESSE3, we evaluate the noise budget of CHRONOS and characterize the relative contributions of quantum, thermal, and environmental noise sources. Our results demonstrate that CHRONOS achieves competitive sensitivity at low frequencies. The feasibility of using CHRONOS in an earthquake early-warning system by detecting prompt gravity-gradient signals is also investigated, and is predicted to be faster by approximately 2.92 to 6.90 seconds within 40 km. These findings highlight the scientific potential of CHRONOS, bridging gravitational-wave astronomy and geophysical monitoring, and motivating further development of low-frequency detector technologies. I Introduction Gravitational waves are ripples in spacetime produced by accelerating massive objects and were first directly detected in 2015 by Advanced LIGO 1 . This has opened a new window into the universe, enabling the study of strong-field gravity theories, compact object populations, and cosmological processes that are otherwise inaccessible through electromagnetic observations. Current ground-based detectors, notably Advanced LIGO, Virgo, and KAGRA, have now approached their design sensitivity 4 ; 5 . This milestone has enabled routine detections and the establishment of gravitational-wave event catalogs. However, further improvements in sensitivity are necessary to probe weaker and more distant sources and to access other frequency bands. Motivated by these goals, several next-generation (third-generation) detectors are under development, including Cosmic Explorer 14 , the Einstein Telescope 13 , as well as alternative designs such as torsion-bar antennas 2 ; 12 and other low-frequency instruments. These detectors aim to extend both the sensitivity and bandwidth of gravitational-wave observations, particularly toward the sub-Hertz regime. Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS) 11 is one proposed detector that targets the low-frequency range of 0.1–10 Hz at a design strain sensitivity of h\sim 10^{-18}\,\mathrm{Hz^{-1/2}} around 2\,\mathrm{Hz} . It incorporates key technologies, including the use of cryogenic operation to suppress thermal noise, a cross torsion-bar configuration to enhance sensitivity to differential rotational motion, and a triangular Sagnac interferometer with speed meter readout scheme to reduce quantum back-action noise, to enable high-sensitivity measurements in the sub-Hz regime. One such application of CHRONOS is in earthquake early detection. Rapid mass redistribution from fault rupture produces a gravitational disturbance that travels at the speed of light and can be detected before the slower seismic P-waves arrive 8 . Such prompt gravitational signals, which have traditionally been treated as noise, can instead be exploited as a signal of interest. In this work, we evaluate the sensitivity of the CHRONOS detector using both analytical and full interferometric simulations performed with FINESSE3, and explicitly quantify its capability to detect prompt gravitational signals from earthquakes as part of an early warning system. This approach enables a direct assessment of CHRONOS not only as a gravitational-wave detector, but also as a candidate instrument for gravity-based early warning systems. II Noise Budget and Sensitivity Gravitational-wave detectors are limited by a combination of quantum (shot and radiation pressure), thermal (coating and bar), and environmental (seismic and Newtonian) noise sources, each dominant in different frequency regimes. Here, we discuss six different noise sources and their models 10 . Shot noise arises from the discrete nature of photons and manifests as fluctuations in the number of output photons detected, dominating at high frequencies 6 . In contrast, radiation pressure noise originates from fluctuations in the momentum transfer of photons to the end test masses (ETM), introducing uncertainty in the position 6 , dominating at low frequencies. Utilizing a speedmeter readout scheme allows partial cancelling of radiation pressure noise at low frequencies. These effects were simulated using FINESSE3. Coating Brownian noise arises from mechanical losses in the mirror coatings, which is particularly significant in the mid-frequency band 9 . Eqn. 1 describes the amplitude spectral density of the displacement noise, where \eta_{g}/L_{\text{bar}} is the geometric conversion factor from physical ETM displacement to interferometer readout, k_{B} is Boltzmann’s constant, T is the coating temperature, \sigma_{s} and Y_{s} are the Poisson ratio and Young’s modulus of the ETM substrate, respectively, \omega_{\text{ETM}} is a geometric factor based on the beam spatial profile, and \phi_{c}^{\text{eff}} is the effective mechanical loss angle of the coating stack. The noise scaling as \sqrt{T} motivates cryogenic operation to mitigate coating Brownian noise. S_{\text{coat}}(\Omega)=\frac{\eta_{g}}{L_{\text{bar}}}\sqrt{\frac{4k_{B}T}{\pi\Omega}}\sqrt{\frac{1-\sigma_{s}^{2}}{\omega_{\text{ETM}}Y_{s}}}\sqrt{\phi_{c}^{\text{eff}}} (1) Bar thermal noise is associated with thermal fluctuations that excite the torsional modes of the bars, leading to angular displacement noise, especially near resonance frequencies. Eqns. 2 - 3 describe the background and rotational bar thermal noise, where \phi_{s}^{\text{eff}} is the effective material loss angle of the bar, \omega_{tb} is the torsional resonance angular frequency, Q=1/\phi_{0} is the mechanical quality factor, I is the torsion bar moment of inertia, and other variables are the same as in Eqn. 1 . The combined bar thermal noise can be obtained via a quadratic sum: S_{\text{bar}}(\Omega)=\frac{\eta_{g}}{L_{\text{bar}}}\sqrt{S_{\text{bar,bg}^{2}(\Omega)}+S_{\text{bar,rot}}^{2}(\Omega)} . Reducing mechanical loss, careful selection of resonance frequencies, and operating at low temperatures are key strategies to mitigating this effect. \displaystyle S_{\text{bar,bg}}(\Omega) \displaystyle= \displaystyle\sqrt{\frac{4k_{B}T}{\sqrt{\pi}\Omega}}\sqrt{\frac{1-\sigma_{s}^{2}}{Y_{s}}}\sqrt{\phi_{s}^{\text{eff}}} (2) \displaystyle S_{\text{bar,rot}}(\Omega) \displaystyle= \displaystyle\sqrt{\frac{4k_{B}T}{I}}\sqrt{\frac{\Omega\omega_{tb}/Q}{(\omega_{tb}^{2}-\Omega^{2})^{2}+(\omega_{tb}\Omega/Q)^{2}}} (3) Seismic noise arises from ground vibrations due to natural anthropogenic activity and dominates at very low frequencies. Eqn. 4 shows the strain sensitivity after attenuation by the suspension system. S_{x}^{\text{ground}} is the measured ground-displacement spectrum at the proposed site, H_{\text{yaw}}(\Omega) is the suspension yaw transfer function, G_{\mu g} is the conversion gain between mechanical torque and gravity acceleration, and G_{\text{pre}} is the attenuation of the pre-isolation system. To mitigate these effects, CHRONOS plans to employ active and passive vibration-isolation platforms and cryogenic suspensions. S_{\text{seis}}(\Omega)=\frac{|H_{\text{yaw}}(\Omega)|}{G_{\mu g}G_{\text{pre}}}S_{x}^{\text{ground}}(\Omega) (4) Although advanced isolation systems can attenuate seismic disturbances, changes in the environmental mass density can still gravitationally couple with the detector, leading to residual motion and gravity-gradient (Newtonian) noise that remain major challenges below a few hertz 8 . Fig. 1 shows the optimized sensitivity of CHRONOS at a 2.5 m detector scale. CHRONOS sensitivity is limited by different noise sources across frequency bands: shot noise from optical phase fluctuations dominates at high frequencies, while radiation-pressure noise rises at lower frequencies but is mitigated by the Sagnac speed-meter configuration. In the 1–10 Hz range, coating Brownian noise sets the limit, marking the transition between quantum and thermal noise regimes. At sub-Hz frequencies, torsion-bar rotational thermal noise becomes dominant due to direct measurement of rotational motion, and at the lowest frequencies, Newtonian noise from Rayleigh-wave-induced fluctuations imposes the fundamental environmental limit, as it cannot be reduced by mechanical isolation. Understanding and mitigating these noise sources is essential for improving detector sensitivity and extending the observable frequency range of gravitational-wave instruments. Figure 1 :

Read the complete text