Phase-space microscopes for quantum gases: Measuring conjugate variables and momentum-weighted densities.
N. R. Cooper, Y. Yang, C. Weitenberg · 2026
Read Phase-space microscopes for quantum gases: Measuring conjugate variables and momentum-weighted densities. by N. R. Cooper, Y. Yang, C. Weitenberg (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-29568.txt.
Introduction
Cooper and co-authors extend quantum gas microscopes to measure phase space. Standard microscopes give sharp views of quantum gases in position space. Their protocols map momentum onto extra degrees of freedom. Positive operator-valued measures do the readout. One mode measures position and momentum jointly, sharing quantum noise between them. The other mode reads how momentum averages vary across space. That mode can reach fine spatial resolution. They show uses of both modes in varied physical settings.
Catalog record
| CREATOR | N. R. Cooper, Y. Yang, C. Weitenberg |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 36937 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.29568
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Phase-space microscopes for quantum gases: Measuring conjugate variables and momentum-weighted densities. N. R. Cooper, Y. Yang, C. Weitenberg Abstract Quantum gas microscopes offer unprecedented insights into quantum many-body states of cold atomic gases. Here we introduce concrete protocols for extending quantum gas microscopes to measure in phase space, by mapping momentum onto auxiliary degrees of freedom and using positive operator-valued measures. We distinguish between two distinct operational modes. In the Husimi-Q phase space microscope, position and momentum are jointly measured; in this mode the fundamental quantum noise appears in the position measurement. Conversely, the averaged-mode phase space microscope extracts the spatial dependence of averages of the momentum density (and its moments); these averages can be retrieved with arbitrary spatial resolution. We illustrate the utility of these techniques in diverse physical settings. Quantum gas microscopes (QGMs) perform the spatially resolved detection of the individual particles in a quantum many-body system of ultracold atoms and allow for microscopic insights into quantum phases Gross and Bakr 2021 . They were first realised in lattice systems Bakr et al. 2010 ; Sherson et al. 2010 and later in the continuum Holten et al. 2021 ; de Jongh et al. 2025 ; Xiang et al. 2025 ; Yao et al. 2025 . Projective measurements of atomic positions allow access not only to density-density correlators Endres et al. 2011 , but also to various multi-point correlators including string order Endres et al. 2011 ; Hilker et al. 2017 ; Koepsell et al. 2019 . Recent experiments went beyond detection in the position basis by measuring local currents and kinetic energy operators along certain bonds of an optical lattice Impertro et al. 2024 ; Impertro et al. 2025 as well as local phases on the lattice sites Brüggenjürgen et al. 2024 . An effective way to overcome the optical diffraction limit is the matter-wave microscope, which magnifies the density distribution prior to optical imaging using two matter-wave lenses formed by quarter-period evolutions in harmonic traps Asteria et al. 2021 ; Brandstetter et al. 2025 . This method also gives access to a matter-wave Fourier space and allows manipulation to provide an analogue of phase-contrast imaging Murthy and Jochim 2019 ; Brüggenjürgen et al. 2024 or access to various long-range off-diagonal correlators Weitenberg et al. 2026 . Here we show how to extend these techniques to phase-space microscopes, which access atomic occupations and correlations jointly in both position and momentum. Despite being conjugate variables – and therefore non-commuting – joint measurements of position and momentum are permitted, albeit at the expense of introducing quantum noise via the measurement apparatus Arthurs and Kelly Jr 1965 ; Peres 1995 . We shall show how this can be done for cold gases by mapping momentum (or some function of it) onto auxiliary degrees of freedom. This allows positive operator-valued measures (POVMs) that reflect the non-commuting observables Peres 1995 . We discuss protocols for mapping momentum space to an auxiliary dimension or to an auxiliary spin by appropriate manipulation in matter-wave Fourier space. We further show that the approach can be adapted to allow measurements of averages of the momentum density (or its moments). Such observables can, in principle, be measured with arbitrary spatial resolution. We illustrate the utility of phase-space microscopes for a variety of physical settings. We first introduce the phase-space microscope for a single particle of mass M moving in a continuous system in one dimension, with system co-ordinate x , and using the z -dimension as the auxiliary space (Fig. 1 ). Figure 1: Sketch of the protocol for mapping momentum to an auxiliary dimension to realize a 1D Husimi-Q phase-space microscope. (a) Two atoms with initial positions x_{1} and x_{2} and momenta p_{1} and p_{2} in the physical x dimension. (b) A T/4 pulse is applied to move to the Fourier plane in the x direction: the horizontal position of a particle now encodes its initial momentum so is labelled by p_{1,2} . (c) A spatially dependent impulse maps this momentum to a momentum in the auxiliary z dimension. (d) A second T/4 pulse along both directions creates an image in the x direction and maps the acquired z momentum to a z displacement. The protocol gives a choice of how to distribute uncertainty between x and p_{x} . The particle starts in the state \Psi_{\rm i}(x,z)=\psi_{\rm i}(x)\phi_{0}(z) where \psi_{\rm i}(x) is the state we wish to characterise. We take \phi_{0}(z)={\rm e}^{-z^{2}/2\sigma^{2}}/(\pi\sigma^{2})^{1/4} , assuming the particle to be in the groundstate of a harmonic confinement in z with oscillator length \sigma . We encode the momentum p_{x} in z by applying a unitary operator \hat{U}_{\rm kick}={\rm e}^{{\rm i}\alpha\hat{p}_{x}\hat{z}/\hbar} (1) that boosts the momentum in the z -direction by p_{x} scaled by a factor \alpha . To do so, one can use a pulsed harmonic trap in x of trapping frequency \omega=2\pi/T for a quarter-period duration T/4 to map momentum p_{x} onto position x , thereby transforming to the Fourier plane. One then applies a potential V_{\rm kick}(x,z)=-\hbar\kappa xz for a short time \tau\ll T , which imparts an x -dependent impulse \hbar\kappa\tau x along z . Such a saddle potential can be realised by a magnetic field away from the Helmholtz condition 1 1 1 This can be achieved via the coil geometry or a current imbalance, with the 1D system oriented at 45 degrees to the coil axis. . Acting with another quarter-period harmonic trap in x then maps back to position space. Denoting the action of each quarter-period harmonic trap (with oscillator length a_{0}=\sqrt{\hbar/M\omega} ) by the unitary operator \hat{U}_{x} , the overall transformation is \hat{U}_{x}{\rm e}^{{\rm i}\kappa\tau\hat{x}\hat{z}}\hat{U}_{x}=\hat{U}_{x}^{2}\;{\rm e}^{{\rm i}\kappa\tau(\hat{p}_{x}a_{0}^{2}/\hbar)\hat{z}} (2) which matches the desired form ( 1 ) with \alpha=\kappa\tau a_{0}^{2} . The prefactor \hat{U}_{x}^{2} just reverses the spatial co-ordinate x\to-x and adds an unimportant phase 2 2 2 If the second quarter-period oscillator has a different length a_{0}^{\prime} , the transformation also provides an overall magnification (a_{0}^{\prime}/a_{0})^{2} . . Finally, we measure the x -position and p_{z} -momentum of the particle in this final state, which we denote by x_{\rm m}\equiv-x (to remove the spatial reversal) and p_{\rm m}\equiv p_{z}/\alpha (to recover p_{x} by removing the scaling by \alpha ). The measurement of p_{z} can be conveniently achieved by applying a quarter-period harmonic oscillator in z simultaneously with the other directions and measuring in position space. The final positions can be imaged by capturing in a lattice, where for a reasonable matter-wave magnification, the discrete position measurement from the lattice will not be limiting. The phase space can then be read out via an image of the x,z plane. Following this protocol, the probability of measuring the particle in the state (x_{\rm m},p_{\rm m}) is readily found to be Sup \displaystyle P(x_{\rm m},p_{\rm m}) \displaystyle= \displaystyle\left|\langle\psi^{(x_{\rm m},p_{\rm m})}_{\rm coh}|\psi_{\rm i}\rangle\right|^{2} (3) where \psi^{(x_{\rm m},p_{\rm m})}_{\rm coh}(x)\equiv{\rm e}^{-(x-x_{\rm m})^{2}/2\sigma_{c}^{2}+{\rm i}p_{\rm m}x/\hbar}/(\pi\sigma_{\rm c}^{2})^{1/4} is the phase-space coherent state centred on (x_{\rm m},p_{\rm m}) with positional uncertainty \Delta x=\sigma_{c}=\alpha\sigma . Eqn. ( 3 ) defines the Husimi-Q representation of the quantum state: it is related to the Wigner function by a convolution that renders it a positive-definite measure in phase space Leonhardt 2010 . Eqn. ( 3 ) shows that our protocol is a POVM in