Process Development and First Cryogenic Operation of Compact Germanium Ring-Contact HPGe Prototypes
Dongming Mei · 2026
Read Process Development and First Cryogenic Operation of Compact Germanium Ring-Contact HPGe Prototypes by Dongming Mei (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-28505.txt.
Introduction
Dong, Panamaldeniya, and Mei report the first cold run of compact germanium ring-contact detectors built for rare-event hunts like LEGEND-1000. The ring-and-groove contact aims to keep point-contact sensitivity in bigger crystals, but its bumpy shape makes fabrication tricky. The team refined drilling, polishing, coating, and mounting, then cooled two prototypes to 77 K. Both biased stably and showed clear gamma peaks from americium and cesium sources. A lithium contact step comes next.
Catalog record
| CREATOR | Dongming Mei |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 70659 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.28505
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Process Development and First Cryogenic Operation of Compact Germanium Ring-Contact HPGe Prototypes Dongming Mei Abstract Rare-event experiments such as LEGEND-1000 pursue a ton-scale search for neutrinoless double-beta decay in 76 Ge and therefore require HPGe detectors with excellent energy resolution, low electronic noise, and scalable low-background packaging. Point-contact-style electrodes have enabled powerful pulse-shape discrimination in prior 76 Ge programs, while inverted-coaxial point-contact (ICPC) detectors extend these advantages to multi-kilogram crystals and form the current LEGEND baseline. Further increasing the mass per detector remains attractive because it can reduce channel count, cabling complexity, and total passive surface area. The germanium ring-contact (GeRC) concept addresses this scaling problem through a recessed ring-and-groove electrode topology designed to preserve point-contact-like low-capacitance signal formation in larger crystals. However, reliable GeRC fabrication has not yet been demonstrated, largely because the non-planar groove surfaces complicate machining, surface recovery, conformal passivation, and especially the eventual formation of a robust lithium-diffused outer contact. This work reports the fabrication and first cryogenic operation of two compact n-type GeRC process-validation prototypes produced from in-house HPGe crystals at the University of South Dakota. An optimized workflow for core drilling, groove cutting, non-planar polishing, conformal a-Ge encapsulation, Al patterning, and GeRC-specific cryogenic mounting was implemented. Two independent sputtering systems were used to test whether the thin-film sequence remains operable across substantially different deposition environments. At 77 K, both devices could be biased stably, showed an inferred depletion onset near 340 V from a pulser-based capacitance proxy consistent with electrostatic modeling, and produced identifiable full-energy peaks from Am 241 {}^{241}\mathrm{Am} and Cs 137 {}^{137}\mathrm{Cs} . These results establish a proof-of-principle process and readout baseline for the geometry-specific steps of GeRC development. They do not yet constitute a deployment-ready large-mass GeRC technology; rather, they define the foundation for the next step, namely integration of conformal lithium-paint deposition and controlled diffusion on the ring-and-groove topology. 1 Background High-purity germanium detectors have evolved substantially over the past decades to meet the demanding requirements of rare-event physics [ 1 , 2 , 3 ] . Coaxial HPGe detectors, traditionally used in \gamma -ray spectroscopy and early neutrinoless double-beta decay (0 \nu\beta\beta ) experiments, provided large crystal masses but with relatively high capacitance and limited event discrimination capability [ 2 , 1 , 3 ] . The development of point-contact detector geometries addressed these limitations. In particular, p-type point-contact (PPC) detectors and Broad Energy Ge (BEGe) detectors were introduced in the 2000s to achieve low capacitance and strong pulse-shape discrimination (PSD) [ 4 , 5 , 6 , 7 ] . Experiments like the Majorana Demonstrator (using PPCs) and GERDA Phase II (using BEGes) showed that such detectors could effectively distinguish single-site signal events from multi-site background interactions, dramatically improving background rejection in 76 Ge 0 \nu\beta\beta searches [ 8 , 9 , 10 , 11 ] . However, these PPC and BEGe devices typically have masses on the order of 0.5–1 kg each; scaling a strict point-contact design to substantially larger crystals becomes challenging because ensuring full depletion with acceptable bias voltages can become impractical [ 7 , 12 , 13 ] . Above roughly the 1–2 kg scale, a simple point-contact geometry can suffer from regions of low field (partial depletion or “pinch-off”) that degrade charge collection and PSD performance [ 14 , 15 , 13 ] . This practical size limitation motivated new detector designs to maintain high performance in larger germanium masses [ 13 , 16 , 1 ] . The inverted coaxial point-contact (ICPC) geometry was developed to enable p-type crystals in the 2–4 kg range while retaining the advantages of a small readout electrode [ 17 , 13 , 16 ] . The ICPC design, originally conceived at ORNL, introduces an extended coaxial-like geometry with a central bore and an inverted electrode configuration that shapes the electric field more uniformly throughout a large crystal [ 17 , 13 , 16 ] . By preserving a point-contact anode and a coaxial cylindrical geometry, ICPC detectors achieve low capacitance and excellent PSD in devices considerably larger than standard PPCs [ 13 , 16 , 10 ] . This technology has been adopted in current 0 \nu\beta\beta projects: for example, the LEGEND-200 experiment operates modules of enriched-Ge ICPC detectors, and the upcoming LEGEND-1000 is planned to deploy on the order of 400 ICPC units of 2–4 kg each to reach a total active mass of one tonne [ 18 , 13 , 16 ] . Using fewer, larger detectors is highly beneficial for ultra-low-background experiments. It reduces the number of electronic channels and cryostat penetrations, simplifies mechanical integration, and decreases the total surface area that could host radioactive contaminants. Each of these factors contributes to a lower background footprint per unit mass of detector [ 13 , 16 , 1 ] . Nonetheless, even the ICPC design may encounter limitations as one pushes to ever larger crystals. It remains to be demonstrated that an ICPC below ~4.5 kg can be fully depleted without any undepleted volume; simulations suggest that at ~5 kg, maintaining adequate field throughout the entire crystal becomes difficult without introducing new electrode structures [ 13 , 16 , 18 ] . Moreover, the primary driver for exploring new HPGe geometries beyond the current ICPC scale is scalability at the module and array level. In a ton-scale 76 Ge experiment, each detector requires at least one high-voltage line and one readout channel; therefore, increasing the mass per detector directly reduces the number of channels and associated cables, simplifies mechanical integration, and lowers the background contribution from cabling and feedthroughs. In addition, larger crystals generally provide higher containment efficiency and an improved mass-to-surface ratio, which together can reduce the background rate per kilogram and strengthen overall sensitivity. These scaling considerations motivate the new geometry as a route to preserve point-contact-like low-capacitance signal formation while extending single-crystal mass into the multi-kilogram regime [ 16 , 13 , 1 ] . A next-generation concept addressing these needs is the germanium ring-contact detector (GeRC) [ 19 , 20 , 21 , 22 , 23 ] . Proposed by D. Radford around 2018, the ring-contact geometry introduces a modified small-electrode topology aimed at enabling multi-kilogram p-type Ge detectors while preserving the low-capacitance response characteristic of point-contact devices [ 19 , 20 , 21 , 22 , 23 ] . In this design, the p + readout electrode is implemented not as a single point on a planar face, but as a narrow ring electrode located on a recessed surface of the crystal [ 19 , 20 , 21 , 22 , 23 ] . Figure 1 presents a schematic cross-sectional illustration of representative groove-based ring-contact configurations. In such implementations, the ring-shaped p + contact is formed on the recessed annular surface, while the remaining outer surface of the crystal serves as the large-area opposing n + electrode [ 19 , 20 , 21 , 22 , 23 ] . By relocating the small readout contact from a planar point to a recessed annular surface, the detector geometry modifies both the electric-field distribution and the weighting potential, providing a practical route toward large detector masses with point-contact-like signal formation and correspondingly low electronic capacitance [ 19 , 20 , 21