Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

D.S. Akerib, A.K. Al Musalhi, F. Alder, B.J. Almquist, C.S. Amarasinghe, A. Ames, T.J. Anderson, N. Angelides, H.M. Araújo, J.E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, J.W. Bargemann, E.E. Barillier, K. Beattie, A. Bhatti, T.P. Biesiadzinski, H.J. Birch, E. Bishop, G.M. Blockinger, C.A.J. Brew, P. Brás, S. Burdin, M.C. Carmona-Benitez, M. Carter, A. Chawla, H. Chen, Y.T. Chin, N.I. Chott, S. Contreras, M.V. Converse, R. Coronel, A. Cottle, G. Cox, D. Curran, C.E. Dahl, I. Darlington, S. Dave, A. David, J. Delgaudio, S. Dey, L. de Viveiros, L. Di Felice, C. Ding, J.E.Y. Dobson, E. Druszkiewicz, S. Dubey, C.L. Dunbar, S.R. Eriksen, N.M. Fearon, N. Fieldhouse, S. Fiorucci, H. Flaecher, E.D. Fraser, T.M.A. Fruth, P.W. Gaemers, R.J. Gaitskell, A. Geffre, J. Genovesi, C. Ghag, J. Ghamsari, A. Ghosh, S. Ghosh, R. Gibbons, S. Gokhale, J. Green, M.G.D.van der Grinten, J.J. Haiston, C.R. Hall, T. Hall, R.H Hampp, S.J. Haselschwardt, M.A. Hernandez, S.A. Hertel, G.J. Homenides, M. Horn, D.Q. Huang, D. Hunt, E. Jacquet, R.S. James, K. Jenkins, A.C. Kaboth, A.C. Kamaha, M.K. Kannichankandy, D. Khaitan, A. Khazov, J. Kim, Y.D. Kim, D. Kodroff, E.V. Korolkova, H. Kraus, S. Kravitz, L. Kreczko, V.A. Kudryavtsev, C. Lawes, E.B. Leon, D.S. Leonard, K.T. Lesko, C. Levy, J. Lin, A. Lindote, W.H. Lippincott, J. Long, M.I. Lopes, W. Lorenzon, C. Lu, S. Luitz, W. Ma, V. Mahajan, P.A. Majewski, A. Manalaysay, R.L. Mannino, R.J. Matheson, C. Maupin, M.E. McCarthy, D.N. McKinsey, J. McLaughlin, J.B. McLaughlin, R. McMonigle, B. Mitra, E. Mizrachi, M.E. Monzani, K. Morå, E. Morrison, B.J. Mount, M. Murdy, A.St.J. Murphy, H.N. Nelson, F. Neves, A. Nguyen, C.L. O’Brien, F.H. O’Shea, I. Olcina, K.C. Oliver-Mallory, J. Orpwood, K.Y Oyulmaz, K.J. Palladino, N.J. Pannifer, S.J. Patton, B. Penning, G. Pereira, E. Perry, T. Pershing, A. Piepke, S.S. Poudel, Y. Qie, J. Reichenbacher, C.A. Rhyne, G.R.C. Rischbieter, E. Ritchey, H.S. Riyat, R. Rosero, N.J. Rowe, T. Rushton, D. Rynders, S. Saltão, D. Santone, A.B.M.R. Sazzad, R.W. Schnee, G. Sehr, B. Shafer, S. Shaw, W. Sherman, K. Shi, T. Shutt, C. Silva, G. Sinev, J. Siniscalco, A.M. Slivar, A.M. Softley-Brown, V.N. Solovov, P. Sorensen, J. Soria, T.J. Sumner, A. Swain, M. Szydagis, D.R. Tiedt, D.R. Tovey, J. Tranter, M. Trask, K. Trengove, M. Tripathi, A. Usón, A.C. Vaitkus, O. Valentino, V. Velan, A. Wang, J.J. Wang, Y. Wang, L. Weeldreyer, T.J. Whitis, K. Wild, M. Williams, J. Winnicki, L. Wolf, F.L.H. Wolfs, S. Woodford, D. Woodward, C.J. Wright, Q. Xia, J. Xu, Y. Xu, M. Yeh, D. Yeum, J. Young, W. Zha, H. Zhang, T. Zhang, Y. Zhou, The LZ Collaboration · 2026

Read Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector by D.S. Akerib, A.K. Al Musalhi, F. Alder, B.J. Almquist, C.S. Amarasinghe, A. Ames, T.J. Anderson, N. Angelides, H.M. Araújo, J.E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, J.W. Bargemann, E.E. Barillier, K. Beattie, A. Bhatti, T.P. Biesiadzinski, H.J. Birch, E. Bishop, G.M. Blockinger, C.A.J. Brew, P. Brás, S. Burdin, M.C. Carmona-Benitez, M. Carter, A. Chawla, H. Chen, Y.T. Chin, N.I. Chott, S. Contreras, M.V. Converse, R. Coronel, A. Cottle, G. Cox, D. Curran, C.E. Dahl, I. Darlington, S. Dave, A. David, J. Delgaudio, S. Dey, L. de Viveiros, L. Di Felice, C. Ding, J.E.Y. Dobson, E. Druszkiewicz, S. Dubey, C.L. Dunbar, S.R. Eriksen, N.M. Fearon, N. Fieldhouse, S. Fiorucci, H. Flaecher, E.D. Fraser, T.M.A. Fruth, P.W. Gaemers, R.J. Gaitskell, A. Geffre, J. Genovesi, C. Ghag, J. Ghamsari, A. Ghosh, S. Ghosh, R. Gibbons, S. Gokhale, J. Green, M.G.D.van der Grinten, J.J. Haiston, C.R. Hall, T. Hall, R.H Hampp, S.J. Haselschwardt, M.A. Hernandez, S.A. Hertel, G.J. Homenides, M. Horn, D.Q. Huang, D. Hunt, E. Jacquet, R.S. James, K. Jenkins, A.C. Kaboth, A.C. Kamaha, M.K. Kannichankandy, D. Khaitan, A. Khazov, J. Kim, Y.D. Kim, D. Kodroff, E.V. Korolkova, H. Kraus, S. Kravitz, L. Kreczko, V.A. Kudryavtsev, C. Lawes, E.B. Leon, D.S. Leonard, K.T. Lesko, C. Levy, J. Lin, A. Lindote, W.H. Lippincott, J. Long, M.I. Lopes, W. Lorenzon, C. Lu, S. Luitz, W. Ma, V. Mahajan, P.A. Majewski, A. Manalaysay, R.L. Mannino, R.J. Matheson, C. Maupin, M.E. McCarthy, D.N. McKinsey, J. McLaughlin, J.B. McLaughlin, R. McMonigle, B. Mitra, E. Mizrachi, M.E. Monzani, K. Morå, E. Morrison, B.J. Mount, M. Murdy, A.St.J. Murphy, H.N. Nelson, F. Neves, A. Nguyen, C.L. O’Brien, F.H. O’Shea, I. Olcina, K.C. Oliver-Mallory, J. Orpwood, K.Y Oyulmaz, K.J. Palladino, N.J. Pannifer, S.J. Patton, B. Penning, G. Pereira, E. Perry, T. Pershing, A. Piepke, S.S. Poudel, Y. Qie, J. Reichenbacher, C.A. Rhyne, G.R.C. Rischbieter, E. Ritchey, H.S. Riyat, R. Rosero, N.J. Rowe, T. Rushton, D. Rynders, S. Saltão, D. Santone, A.B.M.R. Sazzad, R.W. Schnee, G. Sehr, B. Shafer, S. Shaw, W. Sherman, K. Shi, T. Shutt, C. Silva, G. Sinev, J. Siniscalco, A.M. Slivar, A.M. Softley-Brown, V.N. Solovov, P. Sorensen, J. Soria, T.J. Sumner, A. Swain, M. Szydagis, D.R. Tiedt, D.R. Tovey, J. Tranter, M. Trask, K. Trengove, M. Tripathi, A. Usón, A.C. Vaitkus, O. Valentino, V. Velan, A. Wang, J.J. Wang, Y. Wang, L. Weeldreyer, T.J. Whitis, K. Wild, M. Williams, J. Winnicki, L. Wolf, F.L.H. Wolfs, S. Woodford, D. Woodward, C.J. Wright, Q. Xia, J. Xu, Y. Xu, M. Yeh, D. Yeum, J. Young, W. Zha, H. Zhang, T. Zhang, Y. Zhou, The LZ Collaboration (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-26877.txt.

Introduction

Akerib and co-authors push pulse shape discrimination in the LUX-ZEPLIN dark matter detector. The liquid xenon detector hunts weakly interacting massive particles. Its main tool against background is the charge-to-light ratio. Pulse shape adds a second handle on electronic recoil events. The team rebuilds photon timing to form a prompt fraction measure. That alone cuts background leakage to 15 percent, and to about 5 percent for one xenon process. Combining both tools halves the false positive rate for large pulses.

Catalog record

CREATORD.S. Akerib, A.K. Al Musalhi, F. Alder, B.J. Almquist, C.S. Amarasinghe, A. Ames, T.J. Anderson, N. Angelides, H.M. Araújo, J.E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, J.W. Bargemann, E.E. Barillier, K. Beattie, A. Bhatti, T.P. Biesiadzinski, H.J. Birch, E. Bishop, G.M. Blockinger, C.A.J. Brew, P. Brás, S. Burdin, M.C. Carmona-Benitez, M. Carter, A. Chawla, H. Chen, Y.T. Chin, N.I. Chott, S. Contreras, M.V. Converse, R. Coronel, A. Cottle, G. Cox, D. Curran, C.E. Dahl, I. Darlington, S. Dave, A. David, J. Delgaudio, S. Dey, L. de Viveiros, L. Di Felice, C. Ding, J.E.Y. Dobson, E. Druszkiewicz, S. Dubey, C.L. Dunbar, S.R. Eriksen, N.M. Fearon, N. Fieldhouse, S. Fiorucci, H. Flaecher, E.D. Fraser, T.M.A. Fruth, P.W. Gaemers, R.J. Gaitskell, A. Geffre, J. Genovesi, C. Ghag, J. Ghamsari, A. Ghosh, S. Ghosh, R. Gibbons, S. Gokhale, J. Green, M.G.D.van der Grinten, J.J. Haiston, C.R. Hall, T. Hall, R.H Hampp, S.J. Haselschwardt, M.A. Hernandez, S.A. Hertel, G.J. Homenides, M. Horn, D.Q. Huang, D. Hunt, E. Jacquet, R.S. James, K. Jenkins, A.C. Kaboth, A.C. Kamaha, M.K. Kannichankandy, D. Khaitan, A. Khazov, J. Kim, Y.D. Kim, D. Kodroff, E.V. Korolkova, H. Kraus, S. Kravitz, L. Kreczko, V.A. Kudryavtsev, C. Lawes, E.B. Leon, D.S. Leonard, K.T. Lesko, C. Levy, J. Lin, A. Lindote, W.H. Lippincott, J. Long, M.I. Lopes, W. Lorenzon, C. Lu, S. Luitz, W. Ma, V. Mahajan, P.A. Majewski, A. Manalaysay, R.L. Mannino, R.J. Matheson, C. Maupin, M.E. McCarthy, D.N. McKinsey, J. McLaughlin, J.B. McLaughlin, R. McMonigle, B. Mitra, E. Mizrachi, M.E. Monzani, K. Morå, E. Morrison, B.J. Mount, M. Murdy, A.St.J. Murphy, H.N. Nelson, F. Neves, A. Nguyen, C.L. O’Brien, F.H. O’Shea, I. Olcina, K.C. Oliver-Mallory, J. Orpwood, K.Y Oyulmaz, K.J. Palladino, N.J. Pannifer, S.J. Patton, B. Penning, G. Pereira, E. Perry, T. Pershing, A. Piepke, S.S. Poudel, Y. Qie, J. Reichenbacher, C.A. Rhyne, G.R.C. Rischbieter, E. Ritchey, H.S. Riyat, R. Rosero, N.J. Rowe, T. Rushton, D. Rynders, S. Saltão, D. Santone, A.B.M.R. Sazzad, R.W. Schnee, G. Sehr, B. Shafer, S. Shaw, W. Sherman, K. Shi, T. Shutt, C. Silva, G. Sinev, J. Siniscalco, A.M. Slivar, A.M. Softley-Brown, V.N. Solovov, P. Sorensen, J. Soria, T.J. Sumner, A. Swain, M. Szydagis, D.R. Tiedt, D.R. Tovey, J. Tranter, M. Trask, K. Trengove, M. Tripathi, A. Usón, A.C. Vaitkus, O. Valentino, V. Velan, A. Wang, J.J. Wang, Y. Wang, L. Weeldreyer, T.J. Whitis, K. Wild, M. Williams, J. Winnicki, L. Wolf, F.L.H. Wolfs, S. Woodford, D. Woodward, C.J. Wright, Q. Xia, J. Xu, Y. Xu, M. Yeh, D. Yeum, J. Young, W. Zha, H. Zhang, T. Zhang, Y. Zhou, The LZ Collaboration
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE52193
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.26877

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector D.S. Akerib, A.K. Al Musalhi, F. Alder, B.J. Almquist, C.S. Amarasinghe, A. Ames, T.J. Anderson, N. Angelides, H.M. Araújo, J.E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, J.W. Bargemann, E.E. Barillier, K. Beattie, A. Bhatti, T.P. Biesiadzinski, H.J. Birch, E. Bishop, G.M. Blockinger, C.A.J. Brew, P. Brás, S. Burdin, M.C. Carmona-Benitez, M. Carter, A. Chawla, H. Chen, Y.T. Chin, N.I. Chott, S. Contreras, M.V. Converse, R. Coronel, A. Cottle, G. Cox, D. Curran, C.E. Dahl, I. Darlington, S. Dave, A. David, J. Delgaudio, S. Dey, L. de Viveiros, L. Di Felice, C. Ding, J.E.Y. Dobson, E. Druszkiewicz, S. Dubey, C.L. Dunbar, S.R. Eriksen, N.M. Fearon, N. Fieldhouse, S. Fiorucci, H. Flaecher, E.D. Fraser, T.M.A. Fruth, P.W. Gaemers, R.J. Gaitskell, A. Geffre, J. Genovesi, C. Ghag, J. Ghamsari, A. Ghosh, S. Ghosh, R. Gibbons, S. Gokhale, J. Green, M.G.D.van der Grinten, J.J. Haiston, C.R. Hall, T. Hall, R.H Hampp, S.J. Haselschwardt, M.A. Hernandez, S.A. Hertel, G.J. Homenides, M. Horn, D.Q. Huang, D. Hunt, E. Jacquet, R.S. James, K. Jenkins, A.C. Kaboth, A.C. Kamaha, M.K. Kannichankandy, D. Khaitan, A. Khazov, J. Kim, Y.D. Kim, D. Kodroff, E.V. Korolkova, H. Kraus, S. Kravitz, L. Kreczko, V.A. Kudryavtsev, C. Lawes, E.B. Leon, D.S. Leonard, K.T. Lesko, C. Levy, J. Lin, A. Lindote, W.H. Lippincott, J. Long, M.I. Lopes, W. Lorenzon, C. Lu, S. Luitz, W. Ma, V. Mahajan, P.A. Majewski, A. Manalaysay, R.L. Mannino, R.J. Matheson, C. Maupin, M.E. McCarthy, D.N. McKinsey, J. McLaughlin, J.B. McLaughlin, R. McMonigle, B. Mitra, E. Mizrachi, M.E. Monzani, K. Morå, E. Morrison, B.J. Mount, M. Murdy, A.St.J. Murphy, H.N. Nelson, F. Neves, A. Nguyen, C.L. O’Brien, F.H. O’Shea, I. Olcina, K.C. Oliver-Mallory, J. Orpwood, K.Y Oyulmaz, K.J. Palladino, N.J. Pannifer, S.J. Patton, B. Penning, G. Pereira, E. Perry, T. Pershing, A. Piepke, S.S. Poudel, Y. Qie, J. Reichenbacher, C.A. Rhyne, G.R.C. Rischbieter, E. Ritchey, H.S. Riyat, R. Rosero, N.J. Rowe, T. Rushton, D. Rynders, S. Saltão, D. Santone, A.B.M.R. Sazzad, R.W. Schnee, G. Sehr, B. Shafer, S. Shaw, W. Sherman, K. Shi, T. Shutt, C. Silva, G. Sinev, J. Siniscalco, A.M. Slivar, A.M. Softley-Brown, V.N. Solovov, P. Sorensen, J. Soria, T.J. Sumner, A. Swain, M. Szydagis, D.R. Tiedt, D.R. Tovey, J. Tranter, M. Trask, K. Trengove, M. Tripathi, A. Usón, A.C. Vaitkus, O. Valentino, V. Velan, A. Wang, J.J. Wang, Y. Wang, L. Weeldreyer, T.J. Whitis, K. Wild, M. Williams, J. Winnicki, L. Wolf, F.L.H. Wolfs, S. Woodford, D. Woodward, C.J. Wright, Q. Xia, J. Xu, Y. Xu, M. Yeh, D. Yeum, J. Young, W. Zha, H. Zhang, T. Zhang, Y. Zhou, The LZ Collaboration Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as 15 % 15\% . For specific background processes such as 124 Xe double electron capture, the leakage is reduced further to about 5 % 5\% . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized. x I Introduction There is observational evidence for the existence of dark matter at different distance scales from rotation curves 32 at the galactic scale to the isotropy of the cosmic microwave background 21 at the cosmological scale. Weakly Interacting Massive Particles (WIMPs) are a well-motivated candidate for dark matter. Various direct-detection dark matter experiments are searching for WIMPs by detecting the interactions of WIMPs with nuclei. Due to their sensitivity to both spin-independent and spin-dependent WIMP interactions, liquid noble elements are used as target materials, especially liquid xenon (LXe) 30 . The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, located 4850 ft below the surface (4300 mwe) at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The center of LZ is a dual-phase Time Projection Chamber (TPC) which is surrounded by two veto detectors: the Skin detector and the Outer Detector (OD). The entire LZ detector is shielded by 238 tonnes of ultrapure water 9 . The TPC is a cylinder with a diameter and height of 1.5 m, containing 7 tonnes of LXe in its active volume. The top and bottom of the TPC are instrumented with 494 3-inch Hamamatsu R11410-22 photomultiplier tubes (PMTs), distributed over two arrays. These PMTs detect signals produced by Xe recoils and background signals. Interactions in the LXe produce scintillation photons and ionization electrons. The scintillation light is detected first and produces a prompt scintillation signal (S1). The secondary electroluminescence signal (S2) is created by the ionization electrons that drift to the liquid surface and are extracted into the gas phase. Both S1 and S2 pulses are distributed over multiple PMTs in the top and bottom arrays. The event’s (x,y) position is reconstructed using the spatial distribution of the S2 signal on the top array. The time difference between the S1 and S2 pulses provides information about the z -position of the interaction. Multiple radioactive sources are used to calibrate the detector response, including tritiated methane (CH 3 T), 83m Kr, 131m Xe, deuterium-deuterium (DD) neutrons, and americium-beryllium (AmBe) neutrons 3 . LZ began taking data in December 2021. This analysis focuses on the WIMP search (WS) datasets collected between March 2023 and April 2024, referred to as WS2024. Events which pass all data quality (DQ) cuts are referred to as WS events. More details of the WS2024 dataset and the DQ cuts applied can be found in Ref. 4 . The main challenge of dark matter detection is the discrimination between WIMP signals and background events. In LZ, the underground environment and the water shield reduce the backgrounds from cosmic rays and environmental sources. The Skin detector and the OD can provide veto signals to further reject background events. The most prominent remaining backgrounds are mainly from gamma and beta radiation released by the residual radioactivity in the detector materials. Since these background events produce primarily electronic recoil (ER) events, discrimination between nuclear recoil (NR) and ER events is key to the observation of WIMPs. ER events predominately arise from interactions with the atomic electrons of xenon, while NR events result from interactions with the xenon nuclei. For most LXe experiments including LZ, the primary discrimination method is charge-to-light discrimination, which achieves a high rejection efficiency for ER events. To characterize and validate NR and ER