David J. Hoffman, Douglas Garratt, Matthew Bain, Christina Y. Hampton, Benjamin I. Poulter, Jyoti Joshi, Giacomo Coslovich, Frank P. O’Dowd, Daniel P. DePonte, Alexander H. Reid, Lingjia Shen, Daniel Jost, Mina R. Bionta, Joshua J. Turner, Ming-Fu Lin, Philip Heimann, Stefan P. Moeller, Jake D. Koralek, Tyler Johnson, K Ninh, Raybel Almeida, Adam Berges, Stephanie Fung, Shuai Li, Eetu Pelimanni, Amke Nimmrich, Munira Khalil, Linda Young, Thomas J.A. Wolf, Kristjan Kunnus, Georgi L. Dakovski · 2026
Read The chemRIXS Instrument for the LCLS-II X-Ray Free Electron Laser by David J. Hoffman, Douglas Garratt, Matthew Bain, Christina Y. Hampton, Benjamin I. Poulter, Jyoti Joshi, Giacomo Coslovich, Frank P. O’Dowd, Daniel P. DePonte, Alexander H. Reid, Lingjia Shen, Daniel Jost, Mina R. Bionta, Joshua J. Turner, Ming-Fu Lin, Philip Heimann, Stefan P. Moeller, Jake D. Koralek, Tyler Johnson, K Ninh, Raybel Almeida, Adam Berges, Stephanie Fung, Shuai Li, Eetu Pelimanni, Amke Nimmrich, Munira Khalil, Linda Young, Thomas J.A. Wolf, Kristjan Kunnus, Georgi L. Dakovski (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-26774.txt.
Introduction
Hoffman and co-authors describe the chemRIXS instrument built for the LCLS-II X-ray free electron laser. The new superconducting machine delivers far stronger X-ray flux than its copper predecessor. Matching gains in the optical laser and liquid jet systems lift signal quality on dilute samples. That opens time-resolved X-ray absorption and resonant scattering to whole new classes of solution-phase samples. The report walks through the beamline parts, from source to detectors. First commissioning results from LCLS-II running close the account.
Catalog record
| CREATOR | David J. Hoffman, Douglas Garratt, Matthew Bain, Christina Y. Hampton, Benjamin I. Poulter, Jyoti Joshi, Giacomo Coslovich, Frank P. O’Dowd, Daniel P. DePonte, Alexander H. Reid, Lingjia Shen, Daniel Jost, Mina R. Bionta, Joshua J. Turner, Ming-Fu Lin, Philip Heimann, Stefan P. Moeller, Jake D. Koralek, Tyler Johnson, K Ninh, Raybel Almeida, Adam Berges, Stephanie Fung, Shuai Li, Eetu Pelimanni, Amke Nimmrich, Munira Khalil, Linda Young, Thomas J.A. Wolf, Kristjan Kunnus, Georgi L. Dakovski |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 54221 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.26774
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The chemRIXS Instrument for the LCLS-II X-Ray Free Electron Laser David J. Hoffman, Douglas Garratt, Matthew Bain, Christina Y. Hampton, Benjamin I. Poulter, Jyoti Joshi, Giacomo Coslovich, Frank P. O’Dowd, Daniel P. DePonte, Alexander H. Reid, Lingjia Shen, Daniel Jost, Mina R. Bionta, Joshua J. Turner, Ming-Fu Lin, Philip Heimann, Stefan P. Moeller, Jake D. Koralek, Tyler Johnson, K Ninh, Raybel Almeida, Adam Berges, Stephanie Fung, Shuai Li, Eetu Pelimanni, Amke Nimmrich, Munira Khalil, Linda Young, Thomas J.A. Wolf, Kristjan Kunnus, Georgi L. Dakovski Abstract The chemRIXS instrument at the Linac Coherent Light Source offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopy through the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and resonant inelastic X-ray scattering to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopies on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented. I Introduction Figure 1: Schematic overview of the principal X-ray beamline components and optical laser components for the chemRIXS instrument. Purple indicates the X-ray beam, red indicates the OPCPA fundamental (800 nm), and blue indicates the variable-wavelength optical laser beam delivered to the chemRIXS IP. KB: Kirkpatrick-Baez Mirror, ATM: Arrival Time Monitor, OPCPA: Optical Parametric Chirped Pulse Amplifier, OPA: Optical Parametric Amplifier, FIM: Fluorescence Intensity Monitor, APDs: Avalanche Photodiodes, Pol.: Polarizer, \lambda/2 : half-waveplate. The chemRIXS Instrument at the Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Lab is a successor instrument to the liquid jet endstation 26 used at the Soft X-ray Research (SXR) instrument formerly at LCLS. 37 ; 7 ChemRIXS is dedicated to ultrafast soft X-ray spectroscopy on solution-phase systems, which provides great opportunities for studying chemical systems, as the soft X-ray transitions (250-1600 eV) involve core electrons in light elements and third-row transition metals. 43 ; 20 The energies of these transitions have element-dependent binding energies that are usually separated by 10s or 100s of eVs, making the techniques element selective. Combined with femtosecond optical lasers and X-ray free electron lasers (XFELs), which provide tunable, high intensity, femtosecond X-ray pulses, 12 ; 3 these methods can be used for tracking the evolution of both unoccupied and occupied orbitals during photochemical reactions on ultrafast timescales. X-ray absorption spectroscopy (XAS) probes resonances between core to valence electronic orbitals, 43 which can then provide details on the overlap between specific atomic sites (through these core electronic orbitals) and a given valence orbital. After photoexcitation by an optical laser, the time-resolved XAS spectra can report on the evolution of the solvation environment, the depleted ground state, and the evolution of excited states in relation to these core electron orbitals. Complementary information can be obtained by examining the X-ray emission channels. Resonant inelastic X-ray scattering (RIXS) 20 ; 42 ; 8 ; 36 is used to track various energy transfer pathways within the system of interest by spectrally resolving emitted X-ray photons. For chemical systems, this can be used to examine the couplings between occupied and unoccupied valence orbitals with the same element and site specificity provided by XAS. In a single-electron picture of the RIXS process, the monochromatic X-rays first trigger a resonant transition from a core electron to an unoccupied valence orbital. Occasionally, an electron from a different orbital will drop down into the core hole, which emits a photon at a different energy. Time-resolved RIXS can then provide information on how these occupied orbitals evolve after laser excitation, and how they overlap with the corresponding unoccupied orbitals probed by time-resolved XAS. However, there are substantial technical restrictions that have slowed the development of the field: the contrast between solute and solvent is often poor, the fluorescence yields are low due to the high probability of instead emitting electrons through Auger-Meitner decay, and the efficiency of soft X-ray grazing-incidence grating spectrometers is low. 20 For these reasons, time-resolved RIXS in particular is extremely photon-hungry, which, when combined with the additional inherent difficulties of measuring liquid samples in high vacuum, has limited its application to only a handful of high-concentration chemical systems in measurements at previous-generation XFELs. 42 ; 21 ; 24 ChemRIXS addresses these issues by leveraging the orders-of-magnitude improvement in repetition rate offered by the recently commissioned LCLS-II free electron laser at SLAC to use these X-ray photon-hungry experimental techniques. ChemRIXS then uses a corresponding suite of detectors, liquid jet delivery system, and high-repetition-rate optical laser system to enable time-resolved XAS, RIXS, and developing nonlinear soft X-ray spectroscopies on solution-phase systems. In this article, an overview of chemRIXS and its associated beamline, laser infrastructure, detectors, and sample delivery system is presented. We conclude with an overview of early scientific accomplishments made using LCLS-I and the first commissioning results from chemRIXS with the high-repetition-rate LCLS-II beam. II Instrument Components The chemRIXS instrument is located at the second interaction point of Hutch 2.2 of the Near Experimental Hall of the LCLS. A schematic diagram of the principal beamline and instrument components can be found in Fig. 1 . A full description of the beamline optics and other components shared between the three interaction points (IPs; the materials science endstation qRIXS, chemRIXS, and future roll-up endstations respectively) can be found elsewhere, 31 ; 33 but a brief overview is presented here. II.1 XFEL Source ChemRIXS utilizes the soft X-ray (SXR) line of LCLS and was designed around the high-flux capabilities of the LCLS-II accelerator, although for the first few years of its operation (2021-2022) it used the LCLS-I SXR beam. The main difference between the LCLS-I and LCLS-II beam is the repetition rate, where LCLS-I operates at 120 Hz while LCLS-II will eventually be able to operate at nearly 1 MHz. To date, the working repetition rate of LCLS-II has been at 33.2 kHz or at subharmonics thereof (16.6 kHz or 8.3 kHz). The core X-ray and beamline parameters are summarized in Table 1 . The photon energies produced from the variable gap SXR undulators span 200-1600 eV. In the standard self-amplified spontaneous emission (SASE) operation, the X-ray pulses have energies of hundreds of microjoules and pulse durations of tens of femtoseconds. Additional operating modes (self-seeding, 5 attosecond pulses, 10 ; 13 two-color 14 ) that have been used at LCLS-I are also being developed for LCLS-II. Table 1: Core X-ray and beamline parameters for monochromatic operation. Values at chemRIXS IP unless otherwise noted. Beamline Parameter Typical Performance Energy Range (eV) 300-1600 Repetition Rate (Hz) Up to 33163 1 1 1 LCLS-II, as of September 2025 ; 120 2 2 2 LCLS-I Pulse Energy ( \mu J) 400 3 3 3 Before monochromator, optimum, at 400-500 eV Focus ( \mu m) 10-1000 Pulse Duration (fs) 30 4 4 4 Before monochromator Transmission 1-2% 5 5 5 Monochromatized X-ray Polarization Horizontal Resolving Power (E/ \Delta E) 2000 Photon Flux at IP ( s^{-1} ) Up to 2\times 10^{15} a II.2 Beamline Components Before reaching