Reconstructing effective ultrasound transducer models via distributed source inversion Journal: Ultrasonics

Tim Bürchner, Simon Schmid, Ernst Rank, Stefan Kollmannsberger, Andreas Fichtner · 2026

Read Reconstructing effective ultrasound transducer models via distributed source inversion Journal: Ultrasonics by Tim Bürchner, Simon Schmid, Ernst Rank, Stefan Kollmannsberger, Andreas Fichtner (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-24415.txt.

Introduction

Bürchner and co-authors rebuild a working model of an ultrasound transducer by source inversion. Wide transducers excite waves unevenly, which shapes the sound pattern and makes modelling hard. Their method infers a source model in space and time that fits measured wavefields, with no need to know the device structure. Tests on an aluminium half-cylinder match the measured patterns and wave shapes well. Fake imaging tests show good source models lift image quality in migration and full-waveform work.

Catalog record

CREATORTim Bürchner, Simon Schmid, Ernst Rank, Stefan Kollmannsberger, Andreas Fichtner
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE45381
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.24415

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Reconstructing effective ultrasound transducer models via distributed source inversion Journal: Ultrasonics Tim Bürchner, Simon Schmid, Ernst Rank, Stefan Kollmannsberger, Andreas Fichtner Abstract Accurate modeling of ultrasound wave propagation is essential for high - fidelity simulation and imaging in ultrasonic testing. A primary challenge lies in characterizing the excitation source, particularly for transducers with large apertures relative to the acoustic wavelengths. In such cases, non-uniform excitation and spatial interference significantly affect the resulting radiation patterns. This paper proposes a distributed source inversion strategy to reconstruct an effective spatio-temporal transducer model that reproduces experimentally measured wavefields. The reconstructed source model captures aperture-dependent phase and amplitude variations without the need for detailed knowledge of the transducer structure. The approach is validated using directivity measurements on an aluminum half-cylinder, where simulations incorporating the reconstructed source model show close agreement with experimental directivity patterns and waveform shapes. Finally, synthetic studies on reverse time migration and full-waveform inversion demonstrate that accurate transducer modeling is critical for the success of simulation-based imaging and inversion workflows and significantly improves reconstruction quality. 1 Introduction Single-element and phased-array ultrasonic testing (UT) are well-established techniques for defect detection and characterization in non-destructive testing (NDT) [ 1 ] . A common inspection modality is the B-scan, where a transducer is moved along a line in pulse-echo mode to visualize recorded reflections [ 2 ] . Although advanced post-processing methods, such as the synthetic aperture focusing technique (SAFT) [ 3 ] and the total focusing method (TFM) [ 4 ] , significantly improve image resolution, these approaches assume the validity of the (straight) ray approximation. Both techniques typically utilize variants of the delay-and-sum algorithm, which primarily account for the kinematic travel times and amplitudes of reflected waves. Originally developed for seismic exploration, simulation-based imaging frameworks, such as reverse time migration (RTM) [ 5 ] and full-waveform inversion (FWI) [ 6 , 7 ] , aim to exploit the complete information content of recorded wave signals. Unlike ray-based methods, these approaches inherently account for complex wave phenomena, including multiple scattering, diffraction, and mode conversion. RTM constructs reflectivity images by correlating forward-propagated source wavefields with backward-propagated data wavefields. FWI iteratively updates the material model to minimize the misfit between simulated and observed signals. Consequently, the success of these methods depends directly on the accuracy of the underlying wave propagation models. Over the years, FWI has become a well-established tool in seismic tomography, with applications spanning active-source exploration [ 8 , 9 ] , inversion at regional scales [ 10 , 11 ] , and at global scales [ 12 , 13 ] . The method has also gained increasing traction in medical ultrasound, particularly in ultrasound computed tomography (USCT) for breast [ 14 , 15 , 16 ] and transcranial brain imaging [ 17 , 18 ] . By contrast, the application of FWI in NDT remains comparatively limited. This lag is primarily attributed to practical constraints, such as the need for near-real-time results and the frequent inspection of low-cost or high-volume components. Nevertheless, certain applications appear well-suited for FWI. Recent feasibility studies have explored its use in guided-wave tomography [ 19 ] , delamination detection in concrete [ 20 ] , material parameter estimation [ 21 ] , and phased-array UT [ 22 ] . Ongoing research tries to further narrow this gap by leveraging GPU hardware in combination with memory-efficient algorithms [ 23 ] . Since RTM and FWI directly compare simulated wavefields with measured data, the quality of the reconstruction strongly depends on the accuracy of the numerical wave simulation. Consequently, modeling errors or uncertainties regarding the excitation source can significantly degrade imaging performance. While conventional methods like B-scans, SAFT, and TFM are largely agnostic to the source characteristics of the transducer, simulation-based methods require an accurate representation of the emitted ultrasound field. In synthetic benchmarks, the source signature is typically prescribed; however, in experimental practice, the transducer response is generally unknown and must be estimated. Inaccurate source characterization introduces significant discrepancies between simulation and experiment, which can critically deteriorate the convergence and reliability of simulation-based inversion, as shown in [ 24 ] for seismic application. A straightforward approach for source estimation is the extraction of first-arrival waves from experimental data [ 22 ] . More sophisticated strategies, primarily developed for seismic and medical tomography, estimate the source-time function by deconvolving observed waveforms from synthetic data generated using an initial broadband wavelet estimate [ 25 ] . Groos et al. [ 26 ] further refined this technique by incorporating frequency-dependent regularization and receiver-specific weighting. Since the estimated wavelet is intrinsically coupled to the current material model, it is typically re-computed throughout the FWI workflow. This methodology is standard in seismic exploration [ 27 , 28 ] and has also been applied in ultrasonic NDT [ 20 , 29 ] . In USCT, water-shot calibration measurements are commonly employed to compute the source wavelet [ 30 ] . The recovered signal is then associated either with a point source, a distributed source, or a higher-order moment tensor to capture the spatial directivity [ 31 ] . Alternative strategies include signature-free or source-independent FWI [ 32 , 33 , 34 , 35 ] . These approaches circumvent the need for source model calibration by eliminating its signature. This is achieved by convolving the observed wave data with a reference trace from the modeled wave data, and vice versa. A particularly notable contribution in the context of USCT is the recent work by Wu et al. [ 36 , 37 ] , who introduced position-dependent weighting for a virtual source array to recover the transducer directivity. In their approach, the temporal wavelet is recovered via deconvolution, while the spatial excitation weights are determined through gradient-based optimization. Because this calibration is performed using water shots (typically during the initialization phase of the USCT device), analytic solutions of the wave equations can be employed. The resulting calibrated virtual source model accurately reproduces the radiation patterns of both synthetic dipole sources and ultrasound transducers in experiments. Furthermore, there are approaches tailored to industrial UT where the source wavelets are measured directly. In [ 38 ] and [ 39 ] , the source time function is recovered by pressing a receiver against the source and measuring the emitted signal. Representing the transducer by a single point source is feasible if its spatial extent is considerably smaller than the acoustic wavelengths. This is the case, for example, for individual elements within a phased array [ 22 ] . However, if the dimensions of the transducer are on the order of the minimum wavelength, its spatial characteristics must be taken into account. Spatial interference and non-uniform excitation across the aperture (caused by eigenmodes of the piezo crystals [ 40 , 41 ] ) significantly influence the resulting radiation pattern. Schmid et al. [ 21 ] addressed these effects by recovering the characteristics of a disc-shape transducer, specifically its source time function and amplitude distribution using laser Doppler vibrometer (LDV) measurements. Overall, the calibrated source model shows good agreement with a directivity measurement on an aluminum half-cylinder. But, for high aperture angles considerable discrepancies in the wave shapes remain. However, not only the amplitude but also the shape of the source time

Read the complete text