A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison Facilities: Medicina:32m, Sejong, KVN, Yebes:40m. SKED ( 25 ) , DiFX ( 19 ) , fourfit ( 35 ) , ν \nu Solve ( 6 ) , VieVS ( 4 )
Monia Negusini, Myoung-Sun Heo, Cecilia Clivati, Shuangjing Xu, Roberto Ricci, Taehyun Jung, Buseung Cho, Matteo Stagni, Claudio Bortolotti, Giuseppe Maccaferri, Federico Perini, Mauro Roma, Do-Young Byun, Do-Heung Je, Marco Pizzocaro, Davide Calonico, Elena Cantoni, Giancarlo Cerretto, Stefano Condio, Giovanni A. Costanzo, Simone Donadello, Irene Goti, Michele Gozzelino, Filippo Levi, Alberto Mura, Matias Risaro, Huidong Kim, Won-Kyu Lee, Chang Yong Park, Dai-Hyuk Yu, Young Kyu Lee, Joon Hyo Rhee, Chanjin Park, Minseong Lee, Hyo Ryoung Kim, Sung-Moon Yoo, Jungho Cho, Jongsoo Kim, Sang-Oh Yi, Ha Su Yoon, Pablo de Vicente, Javier González, Cristina García Miró · 2026
Read A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison Facilities: Medicina:32m, Sejong, KVN, Yebes:40m. SKED ( 25 ) , DiFX ( 19 ) , fourfit ( 35 ) , ν \nu Solve ( 6 ) , VieVS ( 4 ) by Monia Negusini, Myoung-Sun Heo, Cecilia Clivati, Shuangjing Xu, Roberto Ricci, Taehyun Jung, Buseung Cho, Matteo Stagni, Claudio Bortolotti, Giuseppe Maccaferri, Federico Perini, Mauro Roma, Do-Young Byun, Do-Heung Je, Marco Pizzocaro, Davide Calonico, Elena Cantoni, Giancarlo Cerretto, Stefano Condio, Giovanni A. Costanzo, Simone Donadello, Irene Goti, Michele Gozzelino, Filippo Levi, Alberto Mura, Matias Risaro, Huidong Kim, Won-Kyu Lee, Chang Yong Park, Dai-Hyuk Yu, Young Kyu Lee, Joon Hyo Rhee, Chanjin Park, Minseong Lee, Hyo Ryoung Kim, Sung-Moon Yoo, Jungho Cho, Jongsoo Kim, Sang-Oh Yi, Ha Su Yoon, Pablo de Vicente, Javier González, Cristina García Miró (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-23078.txt.
Introduction
Negusini and co-authors report an intercontinental clock comparison between Italy and Korea using radio telescopes. Geodetic VLBI observations in the K band linked hydrogen masers at Medicina and Sejong. The same clocks were also compared by satellite link and by optical clocks. Those optical clocks sit at the national metrology institutes of both countries. Fiber links carried their signals to the antennas. Results from all routes agreed at a very fine level. The pilot shows standard VLBI campaigns could compare clocks across continents.
Catalog record
| CREATOR | Monia Negusini, Myoung-Sun Heo, Cecilia Clivati, Shuangjing Xu, Roberto Ricci, Taehyun Jung, Buseung Cho, Matteo Stagni, Claudio Bortolotti, Giuseppe Maccaferri, Federico Perini, Mauro Roma, Do-Young Byun, Do-Heung Je, Marco Pizzocaro, Davide Calonico, Elena Cantoni, Giancarlo Cerretto, Stefano Condio, Giovanni A. Costanzo, Simone Donadello, Irene Goti, Michele Gozzelino, Filippo Levi, Alberto Mura, Matias Risaro, Huidong Kim, Won-Kyu Lee, Chang Yong Park, Dai-Hyuk Yu, Young Kyu Lee, Joon Hyo Rhee, Chanjin Park, Minseong Lee, Hyo Ryoung Kim, Sung-Moon Yoo, Jungho Cho, Jongsoo Kim, Sang-Oh Yi, Ha Su Yoon, Pablo de Vicente, Javier González, Cristina García Miró |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 41042 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.23078
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison Facilities: Medicina:32m, Sejong, KVN, Yebes:40m. SKED ( 25 ) , DiFX ( 19 ) , fourfit ( 35 ) , ν \nu Solve ( 6 ) , VieVS ( 4 ) Monia Negusini, Myoung-Sun Heo, Cecilia Clivati, Shuangjing Xu, Roberto Ricci, Taehyun Jung, Buseung Cho, Matteo Stagni, Claudio Bortolotti, Giuseppe Maccaferri, Federico Perini, Mauro Roma, Do-Young Byun, Do-Heung Je, Marco Pizzocaro, Davide Calonico, Elena Cantoni, Giancarlo Cerretto, Stefano Condio, Giovanni A. Costanzo, Simone Donadello, Irene Goti, Michele Gozzelino, Filippo Levi, Alberto Mura, Matias Risaro, Huidong Kim, Won-Kyu Lee, Chang Yong Park, Dai-Hyuk Yu, Young Kyu Lee, Joon Hyo Rhee, Chanjin Park, Minseong Lee, Hyo Ryoung Kim, Sung-Moon Yoo, Jungho Cho, Jongsoo Kim, Sang-Oh Yi, Ha Su Yoon, Pablo de Vicente, Javier González, Cristina García Miró Abstract An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K-band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio telescopes. The same clocks were simultaneously compared by a satellite link and by high-precision optical clocks maintained at the National Metrology Institutes, KRISS in Korea and INRIM in Italy, and delivered to VLBI antennas via optical fiber. The H-masers frequency difference was estimated by extrapolating the clock rate from VLBI data using two geodetic VLBI software. This was subsequently compared with clock differences derived by satellite link and by local optical clocks. Results obtained with different approaches were in agreement at the level of 10 − 15 10^{-15} s/s. This pilot study demonstrates that standard high-frequency (K-band) geodetic VLBI campaigns could be a viable approach to conduct intercontinental clock comparisons, now only possible via satellite links. This uncertainty can be reduced thanks to the planned installation of new-generation, broadband, high-frequency receivers on the involved telescopes. K/Q/W-band geodetic observations will allow an improvement of the accuracy of the resulting group delays through broad bandwidth synthesis from 20 to 100 GHz. Furthermore, the Frequency Phase Transfer (FPT) method will also be explored together with the use of PCAL systems installed at the radio telescopes to improve phase stability and thus allow a better estimation of the station clock parameters. submitjournal PASP I Introduction Very Long Baseline Interferometry (VLBI) is one of the scientific fields that most heavily relies on accurate time and frequency reference signals, demonstrating significant synergy with fundamental metrology. It is based on the simultaneous observations of radio sources with an array of telescopes, each referenced to a local frequency standard. By correlating the radio signals received by the various telescopes it is possible to reconstruct pair-wise propagation delays, that depend on the baseline length and orientation, atmospheric effects and ultimately the radio source position and structure ( 67 ) . Discrepancies in the local clock frequencies and instrumental delays may also play a role. When all effects are taken into account, it is possible for VLBI to reconstruct with good fidelity rich information, e.g., on the position of the radio telescopes, the Earth Orientation Parameters (EOPs), the source positions and structure. Specifically, VLBI and frequency metrology can take mutual advantage from each other: on one side, VLBI resolution could be greatly improved with instrumentation and techniques that are traditionally maintained at Metrological Institutes. These include atomic clocks with state-of-the-art accuracy, today at the 10^{-18} level ( 3 ; 9 ; 50 ; 71 ) , useful to investigate phenomena over timescales of months or years ( 42 ) ; high spectral purity oscillators ( 52 ; 72 ) , crucial in mm- and sub-mm-wavelength observations ( 60 ) ; sub-ns synchronization of remote sites ( 20 ; 69 ) and distribution of atomic clock signals to multiple telescopes via optical fiber, that enable to realize distributed common-clock arrays ( 41 ; 16 ; 8 ) . On the other side, atomic clocks connected to the telescope can be compared worldwide via VLBI. This is important for fundamental metrology, as discussion is ongoing on a future redefinition of the second in the International System of units ( 24 ; 48 ; 63 ; 21 ) . Comparing distant atomic clocks is among the most urgent tasks to gain confidence on the best route to redefinition. Moreover, it allows fundamental physics tests at unprecedented resolution ( 66 ; 44 ) , as well as advanced relativistic geodesy measurements ( 29 ; 50 ; 70 ) . However, clock comparisons represent a challenging task: while regional distances can be covered with fiber optic links ( 51 ; 1 ; 47 ; 22 ; 16 ; 15 ; 37 ; 12 ) , intercontinental clock comparisons are mostly conducted using the Global Navigation Satellite Systems (GNSS), though their performance may not meet the accuracy required for the redefinition ( 2 ; 59 ; 62 ; 46 ; 23 ; 30 ) . Since the end of the 1970s, the geodetic VLBI has been using the S/X band receivers with the aim of monitoring the parameters of the Earth’s orientation, studying the movements of the Earth’s crust and other geophysical phenomena, realizing the international terrestrial and celestial reference frames (ITRF and ICRF). Its application for time and frequency transfer has been investigated since the beginning (e.g. 17 ; 13 ; 36 ) and an uncertainty of 1.5 × 10^{-15} for a time period of 1 day has been reported in an earlier study ( 61 ) . For local H-masers, which have a relative frequency instability well below 10^{-12} , the VLBI-determined clock rate is equivalent to the rate of one clock relative to that of the other clock ( 68 ) . The uncertainties that can be achieved with legacy S/X band observations are not sufficient for optical clocks comparison, so new possibilities are being explored, such as VLBI observations performed with broadband receivers. In 2018/19, an intercontinental comparison of optical clocks was carried out using a broadband VLBI link between Italy and Japan with an uncertainty of 2.8\times 10^{-16} , lower than that achievable by a satellite link and thus particularly promising in a metrological perspective ( 59 ) . However, in that campaign data were collected and analyzed under very special constraints, such as small transportable antennas and broadband NINJA feeds (3-14 GHz) and a direct digitization without baseband conversion ( 68 ) . A new generation of a high-frequency broadband receiver ( > 20 GHz) is beginning to become available globally among VLBI communities, which would be highly effective in calibrating tropospheric phase fluctuations in the millimeter waveband, significantly enhancing the precision of group delay measurements through broad bandwidth synthesis from 20 to 100 GHz. Moreover, they have the potential to reduce frequency-dependent systematic errors, such as source structure ones. The visible source structure on larger scales induces non-closure delays, increasing post-fit delay residuals in geodetic solutions, while the invisible structure within the beam size leads to variations in the source position ( 74 ) . Given the influence of in-beam structure on source positions, the transition to higher radio frequencies may be important for astrometry and geodesy. To fully exploit its potential, a highly stable local frequency reference is required as stated in ( 64 ) and ( 45 )