Design, construction, and operation of a 30-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

M. Yeh · 2026

Read Design, construction, and operation of a 30-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory by M. Yeh (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-20019.txt.

Introduction

Andrade and co-authors describe a 30-ton water-based liquid scintillator detector built at Brookhaven National Laboratory. The medium mixes water and scintillator so both light types can be tuned. Cherenkov and scintillation signals can then be separated in one device. Such detectors could serve neutrino studies across a wide energy range. Metal loading also offers a way to tag neutrons. The team presents the design, the installation, and first running. They even caught a transient optical response during the staged scintillator injection.

Catalog record

CREATORM. Yeh
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE67821
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.20019

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Design, construction, and operation of a 30-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory M. Yeh Abstract Water-based Liquid Scintillator (WbLS) was proposed over a decade ago as a novel detector medium that might allow the separation and tuning of the relative ratio of the Cherenkov and Scintillation signals. A detector deploying this technology could combine GeV-scale and MeV-scale neutrino detection at scale. Furthermore, the metal-loading capability of such a material enables neutron tagging and allows the effective particle containment to be tuned. WbLS is attractive both for the potential to use it in large detectors and the ability to modify the configuration in situ. At Brookhaven National Laboratory (BNL), two prototypes have been built for understanding WbLS properties and stability, with masses of 1-ton and 30-ton, respectively. We present here the 30-ton prototype detector design, installation, and operation. Results from the analysis of data collected in the two detectors will follow in future publications. 1 Introduction Water-based Liquid Scintillator (WbLS) technology is a significant advancement in neutrino detection, which may offer a versatile and cost-effective medium for the next generation of large-scale experiments. WbLS is created by forming stable, nanometer-scale micelles of liquid scintillator within an aqueous solution. This method seeks to combine the advantages of water Cherenkov and liquid scintillator detectors, enabling the simultaneous detection and separation of Cherenkov and scintillation light. As a result, it achieves improved energy resolution compared to a pure water Cherenkov detector, while also offering potential for event imaging and particle identification. These capabilities are crucial for background rejection and could impact sensitivity to a broad range of neutrino physics, ranging from MeV-scale solar and supernova neutrinos to GeV-scale long-baseline neutrino oscillations. The promise of this technology has led to its adoption in several experiments. These initiatives are part of a global, phased R&D program. The goal is to scale WbLS from benchtop concepts to kiloton-scale detectors. Experiments such as ANNIE [ 3 ] at Fermilab utilize WbLS for enhanced neutrino detection, while the Eos detector [ 1 ] at UC Berkeley has being constructed as a 20-ton performance demonstrator to validate key technologies. The proposed Theia experiment [ 4 ] is a multi-kiloton detector with a broad physics program, including studies of neutrino oscillations, neutrinoless double beta decay, and solar neutrinos. WbLS is one candidate for the target medium in Theia . The success of these future projects depends on understanding WbLS behavior at scale. The R&D program at Brookhaven National Laboratory (BNL) is central to this global effort. Our 1-ton prototype has been continuously running for over two years. We have demonstrated the fundamental principles of Gd-compatible WbLS and established the liquid’s initial stability [ 11 ] . Prior work also provided measurements of the light yield and optical properties [ 6 ] . Building on these results, we seek to address scalability. Demonstrating performance in larger volumes requires overcoming key challenges, including maintaining liquid stability, ensuring uniform optical response, and implementing effective purification and circulation in a substantially larger system. To address these questions, we designed, constructed, and commissioned a 30-ton WbLS prototype at BNL. This new detector is an order of magnitude larger in mass, serving as an essential bridge between the 1-ton proof-of-concept and future kiloton-scale experiments. The 30-ton system will provide critical data on long-term stability, optical clarity, and metal-loading capabilities. Its operation provides essential input for de-risking and optimizing the designs of future detectors such as Theia and BUTTON 1kT. This paper details the technical design, construction, and operational experience of the 30-ton WbLS prototype. We will cover the detector design, including the photomultiplier tubes (PMTs), and the WbLS production and circulation system. We will then describe the data acquisition and calibration systems. Following this, we report on the detector commissioning and the WbLS injection process, including initial performance results. The successful operation of this detector is a critical milestone towards demonstrating the viability and scalability of WbLS technology for future large-scale physics applications. 2 Detector Design At the heart of the detector is a cylindrical 316L stainless steel tank with a radius of 1625.6 mm and a half-height of 1503.35 mm, designed to hold 30 tons of the WbLS medium. Unlike many similar detectors, this tank does not have an internal liner; the WbLS is in direct contact with the stainless steel walls. The inner surface of the tank has been passivated to minimize metal ion leaching and improve chemical compatibility with the liquid. This design choice necessitates careful material compatibility studies to ensure the long-term stability of the detector medium. The entire structure is housed in a dedicated facility that includes advanced circulation and purification systems. Fig. 1 shows the detector design sketch and the circulation system outlook. Note that the nanofiltration and Gd systems have been tested but have not yet been commissioned; they are planned for future runs. Figure 1 : Left: the 30-ton PMT arrangement in the tank. Right: The overview of the 30-ton detector facility. The nanofiltration and Gd systems are planned to be commissioned in future runs. The detector is instrumented with 36 10-inch Hamamatsu R16367 photomultiplier tubes (PMTs), which were specifically selected for their compatibility with WbLS. These PMTs are submerged directly in the detector liquid. The arrangement of the PMTs is designed to optimize light collection and event reconstruction: • Bottom PMTs: Twelve PMTs are arranged in a spiral pattern on the detector floor (Fig. 2(a) ). This configuration allows for a detailed mapping of light collection efficiency at various radial distances from the center, which is expected to improve the accuracy of event reconstruction. • Side (wall) PMTs: Twenty-four PMTs are mounted in four rows along the cylindrical wall of the tank (Fig. 2(a) ). This geometric arrangement is crucial for distinguishing between Cherenkov and scintillation light. For vertically traveling cosmic muons, the Cherenkov light is primarily contained within a cone that illuminates the bottom PMTs and the lower two rows of side PMTs (the "in-ring" region). The upper two rows of side PMTs (the "out-ring" region) are largely outside this cone and therefore detect mostly isotropic scintillation light. The difference in the light detected between these two regions provides a method for measuring the scintillation light yield of the WbLS. This PMT geometry provides a photocathode coverage of 7.3% on the bottom and 7.9% on the side. The detector utilizes a dual trigger system to capture a wide range of physics events. Events can be triggered by: • Cosmic muons passing through a set of plastic scintillator paddles located on top of the detector. • A radioactive source tagging PMT for calibration purposes. This dual-trigger approach allows for the study of both external events (cosmic muons) and internal calibration sources. The data acquisition (DAQ) system (details in Sec. 6 ) is designed to handle the signals from all 36 PMTs, digitizing them for offline analysis. A key feature of the 30-ton detector is its multiple in-situ circulation and purification systems. The WbLS is continuously circulated during data taking to maintain its optical clarity and stability. This system is equipped with a self-developed, sequential exchange array, a nanofiltration system, and a gadolinium (Gd) purification system. The nanofiltration and Gd systems have been tested but have

Read the complete text