A Novel Approach for Direct Measurement of the Stretch Factor in Laminar Premixed Hydrogen–Air Flames Affected by Thermodiffusive Instabilities

M. Marburger, C. Möller, A.R.W. Macfarlane,, M. Schneider, B. Traut, C. Hasse, A. Gruber, A. Dreizler, [0pt] Technical University of Darmstadt, Department of Mechanical Engineering, Reactive Flows and Diagnostics [-5pt] Otto-Berndt-Straße 3, 64287 Darmstadt, Germany, [-5pt] Technical University of Darmstadt, Department of Mechanical Engineering, [-5pt] Simulation of Reactive Thermo-Fluid Systems, Otto-Berndt-Straße 2, 64287 Darmstadt, Germany, [-5pt] SINTEF Energy Research, Thermal Energy Department, Trondheim N-7465, Norway, [-5pt] Norwegian University of Science and Technology, Department of Energy and Process Engineering, [-5pt] N-7491 Trondheim, Norway [-20pt] · 2026

Read A Novel Approach for Direct Measurement of the Stretch Factor in Laminar Premixed Hydrogen–Air Flames Affected by Thermodiffusive Instabilities by M. Marburger, C. Möller, A.R.W. Macfarlane,, M. Schneider, B. Traut, C. Hasse, A. Gruber, A. Dreizler, [0pt] Technical University of Darmstadt, Department of Mechanical Engineering, Reactive Flows and Diagnostics [-5pt] Otto-Berndt-Straße 3, 64287 Darmstadt, Germany, [-5pt] Technical University of Darmstadt, Department of Mechanical Engineering, [-5pt] Simulation of Reactive Thermo-Fluid Systems, Otto-Berndt-Straße 2, 64287 Darmstadt, Germany, [-5pt] SINTEF Energy Research, Thermal Energy Department, Trondheim N-7465, Norway, [-5pt] Norwegian University of Science and Technology, Department of Energy and Process Engineering, [-5pt] N-7491 Trondheim, Norway [-20pt] (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-18852.txt.

Introduction

Marburger and co-authors measure the stretch factor in hydrogen-air flames hit by thermodiffusive instability. A rod anchors a V-flame in a laminar premixed flow. Near the rod, the flame stays smooth with a clear angle and burning rate. Downstream, it breaks into cellular wrinkles at a sharp transition. OH-PLIF imaging tracks both branches and their surface angles. Three methods estimate the wrinkled area growth over a smooth reference. The stretch factor falls from about 1.2 to about 0.85 as the fuel share rises, matching theory.

Catalog record

CREATORM. Marburger, C. Möller, A.R.W. Macfarlane,, M. Schneider, B. Traut, C. Hasse, A. Gruber, A. Dreizler, [0pt] Technical University of Darmstadt, Department of Mechanical Engineering, Reactive Flows and Diagnostics [-5pt] Otto-Berndt-Straße 3, 64287 Darmstadt, Germany, [-5pt] Technical University of Darmstadt, Department of Mechanical Engineering, [-5pt] Simulation of Reactive Thermo-Fluid Systems, Otto-Berndt-Straße 2, 64287 Darmstadt, Germany, [-5pt] SINTEF Energy Research, Thermal Energy Department, Trondheim N-7465, Norway, [-5pt] Norwegian University of Science and Technology, Department of Energy and Process Engineering, [-5pt] N-7491 Trondheim, Norway [-20pt]
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE39767
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.18852

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Novel Approach for Direct Measurement of the Stretch Factor in Laminar Premixed Hydrogen–Air Flames Affected by Thermodiffusive Instabilities M. Marburger, C. Möller, A.R.W. Macfarlane,, M. Schneider, B. Traut, C. Hasse, A. Gruber, A. Dreizler, [0pt] Technical University of Darmstadt, Department of Mechanical Engineering, Reactive Flows and Diagnostics [-5pt] Otto-Berndt-Straße 3, 64287 Darmstadt, Germany, [-5pt] Technical University of Darmstadt, Department of Mechanical Engineering, [-5pt] Simulation of Reactive Thermo-Fluid Systems, Otto-Berndt-Straße 2, 64287 Darmstadt, Germany, [-5pt] SINTEF Energy Research, Thermal Energy Department, Trondheim N-7465, Norway, [-5pt] Norwegian University of Science and Technology, Department of Energy and Process Engineering, [-5pt] N-7491 Trondheim, Norway [-20pt] Abstract The present study introduces a novel experimental configuration employing optical OH-PLIF imaging to directly determine the stretch factor ( I 0 I_{0} ) in laminar premixed hydrogen flames as they transition from a quasi-stable to a thermodiffusively unstable regime. The setup consists of a rod-anchored V-shaped flame stabilised in a laminar flow of premixed reactants. In the near field of the anchoring rod, the mildly strained flame remains quasi-stable, characterised by a smooth surface and a well-defined inclination angle ( θ s \theta_{\mathrm{s}} ) relative to the main flow. This region defines the first, stable-branch of the V-flame, with a corresponding burning rate S s S_{\mathrm{s}} . Further downstream, the flame abruptly transitions into a distinct regime dominated by pronounced thermodiffusive (TD) instabilities, as evidenced by cellular structures and a strongly wrinkled flame surface. The distance between this transition point and the anchor decreases with increasing equivalence ratio. This second TD-unstable branch is characterised by a marked increase in the mean flame-surface angle ( θ u \theta_{\mathrm{u}} ) relative to the flow direction, allowing direct evaluation of the increase in global flame speed, S u / S s S_{\mathrm{u}}/S_{\mathrm{s}} , between the stable and TD-unstable branches. Notably, it is assumed that this ratio represents the normalised flame consumption speed S c / S L S_{\mathrm{c}}/S_{\mathrm{L}} . Determination of I 0 I_{0} additionally requires the ratio of increase in surface-area due to the thermodiffusive instabilities (TDI). Three complementary methods are employed to evaluate the flame-surface area of the TD-unstable branches ( A A ), comparing it to a smooth reference area ( A 0 A_{0} ), yielding consistent trends in A / A 0 A/A_{0} across the range of equivalence ratios studied. The resulting I 0 I_{0} estimates, while subject to uncertainties primarily in A A , decrease monotonically with increasing equivalence ratio, from approximately 1.1 1.1 – 1.3 1.3 at ϕ = 0.35 \phi=0.35 to 0.8 0.8 – 0.9 0.9 at ϕ = 0.4 \phi=0.4 , which is consistent with theoretical predictions. Additional numerical simulations in a reduced two-dimensional representation of the experimental configuration show the same transition behaviour and yield qualitatively consistent results. Novelty and significance statement This work introduces a novel method for directly measuring the stretch factor I_{0} from OH-PLIF imaging of rod-anchored lean premixed laminar hydrogen-air V-flames. The method exploits the abrupt transition from a quasi-stable regime with a nearly flat flame surface to a thermodiffusively unstable regime with highly wrinkled flame surfaces. In contrast to jet burners or spherical expanding flames, the proposed configuration enables the onset of thermodiffusive instabilities to be investigated largely independently of configuration-induced effects on the flame dynamics, such as imposed curvature and flame-branch interactions. The well-characterised laminar flow field allows the transition to be reproduced systematically with minimal external perturbations and clearly identified over a relevant range of fuel-lean operating conditions. Complementary numerical simulations in a reduced two-dimensional representation of the experimental configuration reproduce the same qualitative transition behaviour and support the experimental findings. Together, the experimental and numerical results provide a valuable basis for theory development and validation of numerical models for flames prone to thermodiffusive instabilities. Keywords: Premixed Hydrogen-Air Flame; Thermodiffusive Instability (TDI); Stretch factor I_{0} *Corresponding author. † Authors with equal contribution. 1 Introduction Hydrogen ( \text{H}{\vphantom{\text{X}}}_{\smash[t]{\text{2}}} ) is a key energy carrier for decarbonisation [ 16 ] . Lean premixed operation helps mitigate \text{NO}{\vphantom{\text{X}}}_{\smash[t]{\text{x\/}}} emissions in industrial applications. However, the microscopic structure of sub-unity Lewis number flames is strongly affected by preferential and differential diffusion [ 28 ] , making fuel-lean \text{H}{\vphantom{\text{X}}}_{\smash[t]{\text{2}}} flames susceptible to intrinsic thermodiffusive instabilities (TDIs) and thus inherently multidimensional. TDIs enhance the local flame speed and flame surface area (due to the formation of cellular and finger-like structures) [ 1 ] , lead to superadiabatic temperatures, may influence flame flashback [ 30 ] , and have recently also been shown to significantly affect flame–wall interaction (FWI) [ 34 , 35 , 36 , 23 ] . The cellular structures characterising TDIs have been observed for decades [ 44 , 24 , 39 , 25 ] , and the underlying physical mechanisms are detailed, for example, by Williams [ 41 ] . Under turbulent conditions, turbulent eddies interact nonlinearly with preferential and differential diffusion, thereby further enhancing the thermodiffusive (TD) response up to a certain limit [ 2 , 4 , 3 , 5 , 8 , 6 , 38 ] . TDIs have also been investigated in spherically expanding flames [ 9 , 42 ] , Bunsen burners [ 37 ] , and jet flames [ 22 , 38 ] , demonstrating the important roles of turbulence and flame geometry. Moreover, TDIs have been identified in practical combustion systems, such as internal combustion engines, in both experiments [ 43 ] and numerical studies [ 40 ] , emphasizing their significance for real-world operation. In general, the combined effects of turbulence, TDIs, preferential and differential diffusion increase the global flame consumption speed through both an enlargement of the flame surface area and an enhancement of the local flame speed, the latter commonly quantified by the normalised mean local flame speed (stretch factor) I_{0} [ 10 ] . While multidimensional simulations of freely propagating flames can capture intrinsic instabilities [ 20 , 1 , 7 , 19 , 18 , 26 ] and allow I_{0} to be extracted with high accuracy, their computational cost, particularly for fully resolved three-dimensional cases, limits their use in large parametric studies. Nevertheless, empirical models for I_{0} have been developed from two- and three-dimensional simulations of TDIs [ 19 , 18 , 32 ] . Experimental measurements of I_{0} in hydrogen premixed flames remain scarce. A recent study by Chaib et al. [ 13 ] reported measurements of I_{0} in weakly turbulent hydrogen-enriched methane/air flames based on OH-PLIF, utilising OH-intensity gradient magnitudes as markers of TDIs. In this study, a V-flame configuration previously used to investigate FWI in methane, DME and hydrogen flames [ 21 , 45 , 23 ] is adapted to study laminar, TD-unstable hydrogen-air flames at fuel-lean conditions using OH-PLIF, without wall interaction. The diverging branches prevent tip interactions, allowing TDIs to develop freely. The \text{H}{\vphantom{\text{X}}}_{\smash[t]{\text{2}}} flame exhibits two regimes: an upstream smooth front ( stable-branch ) and a downstream wrinkled front ( TD-unstable branch ) with abruptly increased flame angle and local propagation speed at TDI onset. It is proposed that the stretch factor I_{0} can be determined from combined measurements of flame angle and flame surface area, without requiring direct measurement of the fuel consumption speed. Experiments across fuel-lean equivalence ratios use multiple methods to estimate the flame surface area, highlighting

Read the complete text