Read A Minimal-Component 100 MHz Full-Duplex Digital Link Over a Single Coaxial Cable for Laboratory Instrumentation by M.Wiebusch (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-18848.txt.

Introduction

Wiebusch describes a simple full-duplex digital link that runs over one coaxial cable. Lab instruments often need modest bandwidth without complex circuits. A passive resistive hybrid gives line matching and direction split. One logic gate drives the line, and a differential receiver acts as comparator. No modulation, transformers, or echo cancellation are used. The design target is 200 megabits per second over ten meters of RG-178 cable. Tests match the predicted timing jitter, staying under 1.2 nanoseconds peak to peak. An open line end even gives free loopback behavior.

Catalog record

CREATORM.Wiebusch
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE30280
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.18848

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Minimal-Component 100 MHz Full-Duplex Digital Link Over a Single Coaxial Cable for Laboratory Instrumentation M.Wiebusch Abstract We present a minimal-component bidirectional digital interconnect that enables simultaneous transmission and reception of baseband logic signals over a single coaxial cable. The circuit consists of a passive resistive hybrid providing matched line termination and directional separation, a single CMOS logic gate as driver, and a commercial LVDS receiver used as a differential comparator. No active echo cancellation, calibration, or transformer coupling is required. An analytical treatment of the hybrid network is used to determine the system parameter that maximizes the received signal amplitude. SPICE simulations predict deterministic timing errors caused by incomplete separation of transmitted and received signals. Experimental measurements confirm the predicted deterministic jitter and show good agreement with the simulation results. For typical laboratory coaxial cables up to 6 m 6\text{\,}\mathrm{m} , the measured peak-to-peak edge timing error remains below 1 ns 1\text{\,}\mathrm{ns} . A bidirectional transmission experiment with randomized data at 250 M 250\text{\,}\mathrm{M} demonstrates a clearly open eye diagram and confirms reliable full-duplex operation. Due to its simplicity and compatibility with existing coaxial infrastructure, the proposed approach may be useful in laboratory and detector environments where cable routing or feedthrough density is constrained. I Introduction We present a circuit technique enabling simultaneous bidirectional transmission of baseband logic signals over a single coaxial cable without modulation or demodulation. In laboratory and detector environments, coaxial feedthroughs are frequently used to transport timing and control signals across vacuum boundaries. Bidirectional communication typically requires separate lines for transmit and receive, increasing feedthrough count and cable complexity. Similarly, accelerator and large-scale experimental facilities often have pre-existing coaxial cable plants connecting experimental areas to remote counting houses. A technique enabling deterministic full-duplex operation over a single coaxial line can therefore reduce infrastructure requirements and simplify experimental setups. Bidirectional communication over a single transmission line is not a new concept, given that special transformers called telephone hybrids have been used in analog telephone systems for decades to split incoming from outgoing signals to insert repeater amplifiers for long-distance links. The underlying principle is the superposition of forward and backward traveling waves on transmission lines and the use of directional couplers to distinguish between these. Different technologies of directional couplers exist, each with their special use cases. The most common ones are transformer based couplers, coupled transmission line and resistive bridge 8 . The resistive directional bridge has the unique property that it is broadband (limited only by resistor parasitics) and works all the way down to DC. Figure 1: Circuit example of a directional bridge hybrid. The output of the difference amplifier suppresses the forward (L \rightarrow R) signal but outputs the reverse/reflected component from the far side of the transmission line. The bridge is matched to 50\text{\,}\mathrm{\SIUnitSymbolOhm} and terminates the line. II Principle of Operation The relevant topology of such a resistive bridge for our application is shown in fig. 1 . V1 and R1 represent a signal source with 50\text{\,}\mathrm{\SIUnitSymbolOhm} output impedance which drives a signal into a -3\text{\,}\mathrm{dB} symmetric Pi type attenuator formed by R2 - R6 and which is matched to 50\text{\,}\mathrm{\SIUnitSymbolOhm} . Standard attenuator synthesis formulas were used to determine the required resistor values 10 . It shall be noted that the general principle is not limited to 50\text{\,}\mathrm{\SIUnitSymbolOhm} technology and the particular attenuation value of -3\text{\,}\mathrm{dB} . The attenuator is shown here only to illustrate the principle of directional cancellation. The actual transceiver implementation uses a different attenuation value optimized for digital threshold detection. The right terminal of the attenuator is connected to a transmission line T1 with an arbitrary AC impedance Z_{L} at the far end. With the 50\text{\,}\mathrm{\SIUnitSymbolOhm} matching the attenuator also terminates the transmission line so that no reflections occur on its left terminal. Any voltage signal applied to the left terminal L of the filter will result in an attenuated signal at the right terminal R . For symmetry reasons, any voltage signal applied to the right terminal will be attenuated by the same amount in the other direction. atten. gain: \displaystyle g= \displaystyle 0.71\,\,($-3\text{\,}\mathrm{dB}$) (1) \displaystyle\textrm{signal L$\rightarrow$R}:\quad \displaystyle V_{R}= \displaystyle g\cdot V_{L} (2) \displaystyle\textrm{signal L$\leftarrow$R}:\quad \displaystyle V_{L}= \displaystyle g\cdot V_{R} (3) The legs of the Pi filter are subdivided into two resistors, each forming a voltage divider. The divider ratio is also set to g=0.71 ( -3\text{\,}\mathrm{d}\mathrm{B} ). \displaystyle V_{LL}=g\cdot V_{L} (4) \displaystyle V_{RR}=g\cdot V_{R} (5) We now probe the voltage difference V_{rev} between the right terminal R and the left divider terminal LL . We will find that for all signals coming from the left side V_{rev} is zero, because both, R and LL , see V_{L} attenuated by the same amount. \displaystyle\textrm{signal L$\rightarrow$R}:\quad V_{rev} \displaystyle= \displaystyle V_{R}-V_{LL} (6) \displaystyle= \displaystyle g\cdot V_{L}-g\cdot V_{L} (7) \displaystyle= \displaystyle 0 (8) For signals coming from the right side (e.g. reflected by an impedance mismatch Z_{L} at the far end of the transmission line), V_{rev} assumes non-zero values: \displaystyle\textrm{signal L$\leftarrow$R}:\quad V_{rev} \displaystyle= \displaystyle V_{R}-V_{LL} (9) \displaystyle= \displaystyle V_{R}-g\cdot V_{L} (10) \displaystyle= \displaystyle V_{R}-g\cdot g\cdot V_{R} (11) \displaystyle= \displaystyle(1-g^{2})\cdot V_{R} (12) \displaystyle\approx \displaystyle 0.5\cdot V_{R}\quad($-6\text{\,}\mathrm{dB}$) (13) We understand that V_{rev} is an attenuated version of the reverse (backward) traveling signal component of the transmission line which is (in theory) isolated from the signal currently being injected by the voltage source V1 . We have to be aware that the above derivation assumes ideal resistors and exact impedance matching. The bridge circuit is symmetric, thus if we were to probe the voltage difference between L and RR , we would only measure the forward-traveling signal and reject the reverse component. Similar resistive bridge topologies are used in RF power monitoring ICs to separate forward and reflected waves 6 . In our application we wish to make use of the unique properties of this relatively simple circuit for direct baseband communication. For digital logic transmission, perfect analog isolation is not required. Residual coupling of the locally transmitted signal alters the instantaneous waveform amplitude but does not inherently lead to symbol errors, provided that the perturbation is small enough not to introduce additional threshold crossings. The remaining interaction manifests as a deterministic shift in edge timing, as will be discussed in section IV . III Circuit Implementation Figure 2: Conceptual diagram of two identical transceivers connected by a single 50\text{\,}\mathrm{\SIUnitSymbolOhm} cable, forming a full-duplex link. Each unit combines a driver, a resistive hybrid providing directional separation, and an LVDS receiver for recovering and redriving the signal. The intended application is illustrated in fig. 2 . Two identical transceivers are connected by a single 50\text{\,}\mathrm{\SIUnitSymbolOhm} coaxial cable of arbitrary length. A logic signal applied to TTL\_IN of transceiver A appears at TTL\_OUT of transceiver B, and vice versa. Figure 3: Circuit diagram of one bidirectional transceiver. A CMOS logic gate (U1) drives the coaxial line through a resistive hybrid that provides 50\text{\,}\mathrm{\SIUnitSymbolOhm} termination while attenuating the signal by -4.77\text{\,}\mathrm{dB} . The resistor network simultaneously performs directional separation and DC biasing for the LVDS receiver (U2), which is operated as a high-speed differential comparator. The circuit diagram of one such transceiver is shown in fig. 3 . Although more complex than the illustrative example in 1 we can still identify the same

Read the complete text