Read Unrolled Reconstruction with Integrated Super-Resolution for Accelerated 3D LGE MRI by Md Hasibul Husain Hisham, Shireen Elhabian, Ganesh Adluru, Jason Mendes, Andrew Arai, Eugene Kholmovski, Ravi Ranjan, Edward DiBella (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-18309.txt.

Introduction

Hisham and co-authors put a super-resolution net inside MRI rebuild loops for 3D LGE scans. Thin wall parts of the atrium must be found from sparse k-space data. Their hybrid swaps a deep super-resolution net in as the prior step of each loop round. Training runs end to end on preclinical scans thinned after the fact. At all speed-up rates, scores beat three baselines, and left atrium outlines came out more true.

Catalog record

CREATORMd Hasibul Husain Hisham, Shireen Elhabian, Ganesh Adluru, Jason Mendes, Andrew Arai, Eugene Kholmovski, Ravi Ranjan, Edward DiBella
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE19491
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.18309

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Unrolled Reconstruction with Integrated Super-Resolution for Accelerated 3D LGE MRI Md Hasibul Husain Hisham, Shireen Elhabian, Ganesh Adluru, Jason Mendes, Andrew Arai, Eugene Kholmovski, Ravi Ranjan, Edward DiBella Abstract Accelerated 3D late gadolinium enhancement (LGE) MRI requires robust reconstruction methods to recover thin atrial structures from undersampled k-space data. While unrolled model-based networks effectively integrate physics-driven data consistency with learned priors, they operate at the acquired resolution and may fail to fully recover high-frequency detail. We propose a hybrid unrolled reconstruction framework in which an Enhanced Deep Super-Resolution (EDSR) network replaces the proximal operator within each iteration of the optimization loop, enabling joint super-resolution enhancement and data consistency enforcement. The model is trained end-to-end on retrospectively undersampled preclinical 3D LGE datasets and compared against compressed sensing, Model-Based Deep Learning (MoDL), and self-guided Deep Image Prior (DIP) baselines. Across acceleration factors, the proposed method consistently improves PSNR and SSIM over standard unrolled reconstruction and better preserves fine cardiac structures, leading to improved LA (left atrium) segmentation performance. These results demonstrate that integrating super-resolution priors directly within model-based reconstruction provides measurable gains in accelerated 3D LGE MRI. 1 Introduction Late gadolinium enhancement (LGE) MRI is clinically useful for visualizing left atrial fibrosis in patients with atrial fibrillation, enabling pre-ablation planning and post-procedure assessment [ 17 ] . Current 3D LGE-MRI protocols, while effective, require lengthy acquisition times (typically 7–20 minutes), resulting in patient discomfort and increased susceptibility to motion artifacts [ 12 ] . Accelerating acquisition via k-space undersampling is therefore a critical clinical need. But recovering diagnostic-quality images from highly undersampled measurements poses a challenging ill-posed inverse problem, particularly for 3D LGE imaging where precise visualization of thin atrial walls is essential. In this setting, even subtle loss of high-frequency detail can obscure fibrosis boundaries and compromise downstream quantitative analysis, making reconstruction fidelity at fine spatial scales especially critical. Traditional compressed sensing (CS) reconstruction enables acceleration by exploiting the sparsity of MRI data, formulating reconstruction as a regularized inverse problem that balances data fidelity with handcrafted priors [ 7 , 11 , 1 , 6 ] . CS-based reconstruction has since become the clinical standard for accelerated MRI acquisition [ 10 ] . However, under higher acceleration factors CS may attenuate fine structural detail due to the smoothing effects of sparsity-promoting regularization. Moreover, CS requires careful hand-tuning of regularization parameters and remains computationally intensive, often requiring hours per volume. Supervised deep learning methods have demonstrated strong reconstruction performance [ 16 , 21 ] . However, purely data-driven approaches may implicitly learn acquisition-specific biases and typically require large paired datasets of undersampled and fully-sampled acquisitions, which presents a fundamental barrier in cardiac imaging. In the cardiac domain, acquiring motion-free, fully sampled 3D LGE volumes at high spatial resolution is particularly challenging, limiting the availability of high-quality reference data. Unsupervised methods offer a compelling alternative by eliminating this data dependency [ 18 ] . In particular, Deep Image Prior (DIP)-based approaches leverage the implicit bias of convolutional network architectures as a learned prior [ 3 , 9 ] . Nevertheless, such methods rely primarily on implicit architectural regularization and optimize network parameters independently for each image, without learning a shared prior across subjects. This can limit reconstruction robustness and stability under high acceleration, particularly when recovering fine anatomical detail. Model-based unrolled reconstruction methods offer a principled middle ground, integrating learned image priors with physics-based data consistency through alternating proximal gradient and conjugate gradient steps [ 2 , 14 ] . Unlike purely data-driven approaches, unrolled methods explicitly incorporate the MRI forward model (SENSE encoding), promoting reconstructions that remain faithful to acquired measurements. However, in most implementations the learned proximal operator is designed primarily for denoising at the acquired spatial resolution, which may limit recovery of high-frequency anatomical detail under aggressive undersampling. Enhanced Deep Super-Resolution (EDSR) networks [ 15 , 30 ] have demonstrated strong performance in recovering high-frequency image detail. This raises a key question: can super-resolution priors be embedded directly within the unrolled reconstruction framework to enhance fine structural recovery while preserving strict data consistency? Rather than applying super-resolution as a post-processing step, integrating it within each unrolled iteration may enable joint optimization of resolution enhancement and measurement fidelity, potentially yielding improvements beyond what either approach achieves independently. In this work, we investigate this hypothesis on preclinical (canine) 3D LGE cardiac MRI data. Specifically, we integrate an Enhanced Deep Super-Resolution (EDSR) network within each iteration of a model-based unrolled reconstruction framework, replacing the conventional denoising proximal operator with a super-resolution–aware prior. Super-resolution for MRI image restoration has been explored through CNN-based methods [ 13 , 22 , 20 , 5 ] , Low-rank based methods [ 24 , 4 ] , SMORE method [ 31 ] , etc. However, these methods have been primarily validated on brain or musculoskeletal imaging, leaving cardiac applications largely unexplored. The cardiac domain presents unique challenges: respiratory and cardiac motion introduce artifacts that compound with undersampling degradation, and thin structures such as the left atrial wall demand high fidelity in atrial fibrosis settings. This motivates integrating super-resolution capability directly within the reconstruction loop. We compare the proposed approach against traditional CS [ 1 ] , unrolled Model-Based Deep Learning (MoDL) with a U-Net denoiser [ 2 ] , and self-guided Deep Image Prior (DIP) as an unsupervised reference [ 9 ] . For MRI, downstream tasks such as quality assessment [ 26 ] , classification [ 28 ] , and segmentation [ 19 ] are typically studied on fully-sampled images. Evaluating them on reconstructed outputs provides a more clinically grounded assessment beyond PSNR/SSIM alone. We additionally evaluate downstream LA (left atrium) segmentation, reflecting the clinical sensitivity of fibrosis delineation to fine structural preservation. Our contributions are as follows: • We propose a super-resolution–enhanced unrolled reconstruction framework that embeds EDSR directly within the iterative optimization loop, enabling joint enhancement of high-frequency anatomical detail and physics-based data consistency for accelerated 3D LGE-MRI. • We demonstrate that this integration yields consistent improvements in PSNR and SSIM over standard unrolled reconstruction across acceleration factors, and improves downstream LA segmentation performance, providing a more clinically grounded evaluation than reconstruction metrics alone. 2 Methodology Figure 1: Proposed Unrolled EDSR framework. The EDSR Net serves as the learned proximal operator at each of the N unrolled iterations, with weights \phi shared across iterations. The initial reconstruction \mathbf{x}^{(0)}=\mathbf{A}^{H}\mathbf{y} is the zero-filled adjoint, and data consistency (DC) enforces k-space fidelity via conjugate gradient at each step. We address the problem of reconstructing a 2D MRI image from undersampled multi-coil 3D k-space measurements. For each axial slice, the input is multi-coil k-space data \mathbf{y}\in\mathbb{C}^{N_{c}\times N_{x}\times N_{y}} , where N_{c} is the number of receiver coils and N_{x},N_{y} are the k-space dimensions. The acquisition is governed by a pseudo-random undersampling mask \mathbf{M}\in\{0,1\}^{N_{x}\times N_{y}} with a densely sampled center, and coil sensitivity maps \mathbf{S}\in\mathbb{C}^{N_{c}\times N_{x}\times N_{y}} . The SENSE forward model per coil c is: \mathbf{y}_{c}=\mathbf{M}\odot\mathcal{F}(\mathbf{S}_{c}\cdot\mathbf{x}) (1) where \mathcal{F} denotes the 2D Fourier transform and \odot is the element-wise product. The goal is to recover the reconstructed magnitude image \hat{\mathbf{x}}\in\mathbb{R}^{N_{x}\times N_{y}} per slice. All methods described below operate slice-by-slice in 2D. The SENSE encoding operator is defined compactly as \mathbf{A}=\mathbf{M}\odot\mathcal{F}\mathbf{S} , with \mathbf{A}^{H} denoting its adjoint. 2.1 Baselines Compressed

Read the complete text