Temperature in Glass Slides: measurement using Phase Sensitive Optical Coherence Tomography and Computational Modeling
Folgueiras M. Jose, Chej G. L., Zurdo L. L., Monastra A. G., Morel E. N., Carusela M. F., Torga J. R., [email protected] · 2026
Read Temperature in Glass Slides: measurement using Phase Sensitive Optical Coherence Tomography and Computational Modeling by Folgueiras M. Jose, Chej G. L., Zurdo L. L., Monastra A. G., Morel E. N., Carusela M. F., Torga J. R., [email protected] (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-18226.txt.
Introduction
Folgueiras and co-authors measure temperature in glass slides with phase-sensitive optical coherence tomography. A common-path spectral-domain system tracked optical path changes in a 1 mm soda-lime slide. Path change tracked temperature in a straight line from 20 to 52 degrees Celsius. Measured sensitivity was 12.4 nanometers per degree, with sub-10 nanometer stability in repeat scans. Finite volume models of the thermal gradients matched experiments within 5% error.
Catalog record
| CREATOR | Folgueiras M. Jose, Chej G. L., Zurdo L. L., Monastra A. G., Morel E. N., Carusela M. F., Torga J. R., [email protected] |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 31290 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.18226
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Temperature in Glass Slides: measurement using Phase Sensitive Optical Coherence Tomography and Computational Modeling Folgueiras M. Jose, Chej G. L., Zurdo L. L., Monastra A. G., Morel E. N., Carusela M. F., Torga J. R., [email protected] Abstract Phase-sensitive optical coherence tomography (PhS-OCT) enables precise, contactless measurements of temperature-dependent changes in transparent solids. In this work, we used a common-path spectral-domain OCT system to measure optical path differences (OPD) in a 1-mm-thick soda-lime glass slide immersed in a thermal bath. The OPD variation showed a strong linear correlation with temperature in the range of 20 − 52 20-52 °C \text{\,}\mathrm{\SIUnitSymbolCelsius} , with an experimentally determined sensitivity of 12.4 ± 1.9 12.4\pm 1.9 [nm/ °C \text{\,}\mathrm{\SIUnitSymbolCelsius} ]. A theoretical model incorporating the thermo-optic and thermal expansion coefficients of glass was proposed to interpret the measurements, and numerical simulations based on finite volume methods were performed to account for spatial temperature gradients in the system. The simulations showed agreement with experimental results within 5% error, validating the approach. Additionally, repeatability tests using lateral scans at constant temperature demonstrated sub-10 nm stability, supporting future extensions to spatially resolved thermal mapping. This technique provides a low-cost platform for localized temperature sensing in solid transparent materials. 1 Introduction Contactless and localized temperature measurement plays a key role in applications that require temperature mapping inside a material, as well as the evaluation of spatial and temporal gradients and variations. The use of invasive methods can alter the properties of the material or a complex system, especially in small volumes at the micro and nanoscale, such as in microfluidics, lab-on-a-chip systems [ 1 ] , or in the manufacturing of semiconductor devices or thin films [ 2 ] . There are a wide variety of techniques to measure temperatures. Among the most commonly used, we can mention those based on the expansion of liquids and solids, electrical resistance, and radiation [ 3 ] . However, optical methods offer the possibility of measuring contactless, spatially localized, and time-resolved [ 4 ] . Among the most commonly used optical techniques, we can mention optical fibers, Bragg gratings, infrared thermography, Raman spectroscopy, and interferometric optical methods [ 5 ] . The latter have gained attention due to their high sensitivity, spatial resolution, and high sampling frequency. In particular, one of the optical variants, Optical Coherence Tomography (OCT), has been used to obtain temperature measurements through the precise measurement of Optical Path Differences (OPD) at the micron scale, displaying the relationship between temperature changes and the optical and mechanical effects of the sample material [ 6 , 7 ] . A further development of this technique, known as Phase-Sensitive Optical Coherence Tomography (PhS-OCT) [ 8 , 9 , 10 ] , uses phase information from the interference spectrum to overcome the typical axial resolution limitations of standard OCT, improving the sensitivity of the OPD measurement to the nanometer scale. A common-path configuration of PhS-OCT has shown excellent phase stability, allowing detection of optical path difference changes below 0.5 nm [ 11 , 12 ] . The OPD variation detected by this technique can be correlated with changes in the refractive index and material expansion.This has enabled a broad range of applications including optical coherence elastography [ 12 ] , strain field characterization in polymers [ 13 ] , monitoring of damage repair in composites [ 14 ] , curing process characterization [ 15 ] and temperature sensing. In this context, PhS-OCT has proven to be a highly sensitive technique for measuring temperature and absorption coefficients [ 7 , 16 ] . It has been successfully used to correlate thermal expansion in applications such as bone surgery [ 17 , 18 ] and as a complementary modality to photothermal optical coherence tomography (PT-OCT) [ 10 ] . More recently, it has been applied to monitor tissue temperature rise and thermal deformation during retinal laser therapy [ 19 , 20 ] . This work presents a new PhS-OCT approach, specifically optimized for temperature sensing, with core novelty in the use of a standard glass slide as a calibrated interferometric thermometer. To our knowledge, this concept—employing a simple, low-cost, and easily modeled commercial substrate as a temperature probe—has not been previously demonstrated. Our system employs a simplified common - path configuration in which both surfaces of the slide serve as the sample and reference arms, enabling straightforward implementation. We employ direct empirical calibration of the OPD-temperature relationship through controlled experiments across a physiologically relevant range (20–50°C). Furthermore, we provide comprehensive uncertainty quantification following standardized guidelines, enabling reliable temperature measurements with well-characterized confidence intervals. This end-to-end methodology offers advantages in material simplicity, cost-effectiveness, and minimal invasiveness for applications where introducing complex custom sensors is undesirable. We used a Fourier domain optical coherence tomography (FD-OCT) system, a configuration of OCT that employs a spectrometer as the detector, to obtain a relation between the OPD and temperature on a glass slide (soda lime) immersed in a thermal bath. We considered a common-path configuration that provides additional stability against external disturbances [ 21 ] . The results showed a linear correlation between OPD and temperature variation [ 10 ] .The capacity of this technique to obtain the temperature inside a liquid was verified using the glass slide as a “thermometer”. A computational model of the thermal behavior of the system was also presented in this work, incorporating both the thermal expansion of the material and changes in its refractive index. This model provided a theoretical framework to support the interpretation of experimental OPD-temperature data. The model was validated with our experimental data, showing good correlation between measurements and simulations. These finite volume-based simulations are widely used for thermal analysis [ 22 ] and were adapted here to match our experimental conditions. 2 Theoretical Approach To determine the slide’s temperature via OPD measurements, we analyzed the interference signal generated between reflections from both surfaces under normal laser incidence. For a laser source with spectral distribution S(k) (centered at wave vector k_{0} ), the intensity I(k) of the interference signal is [ 23 ] : I(k)=S(k)\left[(R_{\textrm{R}}+R_{\textrm{S}})+2\sqrt{R_{\textrm{R}}R_{\textrm{S}}}\textrm{ }(cos(2kz(T))\right] (1) where k is the wave vector, R_{\textrm{R}} and R_{\textrm{s}} are the reflectivities of both surfaces of the slide and z(T) is its OPD at temperature T . The phase \phi of the Fourier transform of the interference signal relates to the OPD through [ 23 ] : \phi(z_{i})=k_{0}(z_{i}-2z(T)) (2) Here, z_{i} is the position along the Fourier-conjugate axis of k. Traditional approaches to obtaining the phase usually employ a single point in the Fourier transform of the interference signal, typically at the maximum of its modulus. In this work, a new method was used, utilizing multiple points within a region named the Maximum Amplitude Zone (MAZ) to improve the accuracy and robustness of the measurement. The procedure to retrieve the phase consisted of the following steps: 1. Fourier Transform : A Fourier transform was applied to the interference signal to obtain the modulus and phase in the Fourier-conjugate axis domain ( z_{i} ). 2. Selection of the Maximum Amplitude Zone (MAZ): A maximum amplitude zone was defined around the peak of the modulus, where the signal-to-noise ratio (SNR) is optimal. This zone was selected using a threshold of 50% of the maximum modulus