Read Applicability of Radiowave Anechoic Chambers for Acoustic Free-Field Measurements on the Example of the Chamber at ITMO University by Farid Bikmukhametov, Ksenia Razrezova, Roman Smolnitsky, Yuri Shchelokov, Nikolay Kanev, Mariia Krasikova (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-16556.txt.

Introduction

Bikmukhametov and co-authors test whether a radio anechoic chamber can double for sound work. Acoustic chambers are costly and rare, like radio ones. Radio absorber materials may also soak up sound. The team measured the ITMO University chamber in Saint Petersburg. They checked its coatings by measurement and numeric modeling. Sound level, background noise, and echo time followed the ISO standard. The chamber qualifies as acoustic anechoic only in set frequency bands. Usable distances also depend on direction.

Catalog record

CREATORFarid Bikmukhametov, Ksenia Razrezova, Roman Smolnitsky, Yuri Shchelokov, Nikolay Kanev, Mariia Krasikova
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE23514
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.16556

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Applicability of Radiowave Anechoic Chambers for Acoustic Free-Field Measurements on the Example of the Chamber at ITMO University Farid Bikmukhametov, Ksenia Razrezova, Roman Smolnitsky, Yuri Shchelokov, Nikolay Kanev, Mariia Krasikova Abstract Acoustic anechoic chambers allow free-field measurements required for the verification of effects under investigation and for the characterization of developing devices. However, the construction of an anechoic chamber is a labor-intensive process that requires a lot of resources, which is why these facilities are rather rare. An analogous statement can be made about radiowave chambers. At the same time, it is known that materials for radiowave absorption might absorb acoustic waves as well, and it can be expected that some chambers can be utilized for both electromagnetic and acoustic free-field measurements. This work examines the feasibility of the radiowave anechoic chamber of ITMO University (Saint-Petersburg, Russia) for acoustic measurements. The acoustic properties of the chamber coatings are estimated via measurements and numerical calculations. Characterization of sound pressure level, background noise level, and reverberation time is performed in accordance with the ISO 3745:2012 standard. The key conclusion is that the chamber can be considered as an acoustic anechoic chamber, but only for specific frequency ranges and distances from the source, which depend on the measurement directions. [orcid=0009-0004-6950-9216] [] [] [] [orcid=0000-0001-6512-7131] [orcid=0000-0002-5950-4807] keywords acoustic anechoic chamber ,radiowave anechoic chamber ,free-field measurements 1 Introduction An essential stage of research and development work is the characterization of the systems under development, which typically requires high-precision measurements. Many of the testing procedures must be conducted under the free-field condition, when the amplitude is inversely proportional to the distance from the source [ 35 ] . When this condition is satisfied, it can be assumed that waves reflected from the surfaces of the surrounding space do not affect the results of measurements. For example, free-field conditions are required to determine the directivity and amplitude-frequency characteristics of loudspeakers [ 5 ] , perform microphone calibration [ 8 , 51 ] , characterize musical instruments [ 43 ] , test hearing aids [ 22 ] or investigate noise barriers [ 38 , 29 , 42 , 4 ] . Free-field conditions can be implemented for measurements conducted in anechoic chambers representing rooms in which the scattering is suppressed by using absorbing coatings covering the surfaces of the room [ 48 ] . Depending on the locations of the absorbing coatings, chambers can be classified into two types: semi-anechoic and fully anechoic. In the first case, the coatings cover the walls and ceiling of the chamber, while in the second case the floor is also covered to minimize the influence of reflections on the measurements. Usually, coatings are represented by arrays of wedges made of porous materials, such as glass wool [ 46 ] , fiberglass [ 13 , 40 , 49 , 50 ] , ultra-fine basalt fiber [ 31 ] , or phenolic felt [ 14 ] . At the same time, despite the abundance of various sound-absorbing materials, the quest to find the most efficient one is still open [ 15 , 6 , 9 , 21 , 12 ] . Figure 1: Considered system. (а) Photo of the anechoic chamber as well as photo and the schematic image of a pyramid element of the absorbing coating. (b) Measurement scheme with marked points at which the sound pressure level (red dots), background noise (orange dots) and reverberation time (green dots) are measured. The measurement directions are marked by indexes I – IV. While anechoic chambers are crucially important facilities for acoustic measurement and testing, each camera represents a rather unique object [ 1 , 13 , 14 , 28 , 47 ] , as the construction of the chambers is a laborious and resource intensive process. At the same time, anechoic chambers are constructed not only for acoustic measurements but also for electromagnetic ones [ 48 ] . The coatings absorbing radio-waves can be made of carbon-impregnated polyurethane [ 26 ] , ferrite [ 16 , 36 ] , foil-coated polymers [ 7 ] , or activated charcoal made of coconut shells [ 41 ] . It is noteworthy that some materials can absorb both acoustic and radio-waves. These might be carbon fibers [ 45 ] , polymer nanocomposites [ 37 ] , charcoal [ 44 , 27 ] , or metamaterials [ 39 , 18 ] . Therefore,it can be expected that in some spectral ranges radio-wave anechoic chambers can be considered as acoustic ones and vice versa. The aim of the work is to determine the suitability of the radio-wave anechoic chamber of ITMO University (Saint-Petersburg, Russia) for free-field acoustic measurements. Characterization of the chamber is performed in accordance with the ISO 3745:2012 / GOST-ISO 3745-2014 standard, which defines the requirements imposed on the sound pressure levels and background noise level. Additionally, acoustic absorption coefficient of the chamber coatings is estimated. It is demonstrated that the chamber can be utilized as an acoustic anechoic chamber in the case of measurements near the sound source (at the distances up to 0.9\text{\,}\mathrm{m} ) at the frequencies up to 3150\text{\,}\mathrm{Hz} . The free-field condition is also satisfied for wider spectral ranges and at larger distances from the source, but whether the criteria for acoustic chambers are satisfied depends on the measurement directions. Therefore, the main conclusion of the work is that the radio-wave anechoic chamber of ITMO University is suitable for acoustic measurements under the free-field conditions at specific spectral ranges. 2 Description of the chamber The chamber represents a room having the shape of a rectangular parallelepiped. Without coatings, the length of the walls is 4.46 and 6.96\text{\,}\mathrm{m} , and the height of the ceiling is 3.3\text{\,}\mathrm{m} . The coatings represent arrays of pyramid elements with a square base [see Fig. 1 (a)], which are made of open cell foam rubber saturated with finely-dispersed carbon particles with admixture of metal oxides (about 2 – 3 %). The height of each pyramid is 425\text{\,}\mathrm{mm} , while the thickness of the base is 35\text{\,}\mathrm{mm} , and the width of the base is 150\text{\,}\mathrm{mm} . To improve the radio-wave absorption, the apex parts are treated with a special solution the composition of which is unknown. It should be noted that there is a recess in the floor of the chamber that is 0.15\text{\,}\mathrm{m} deep, 1.3\text{\,}\mathrm{m} wide and 3.55\text{\,}\mathrm{m} long. Due to operational necessity, the recess is not covered by the absorbing coatings, as can be seen in Fig. 1 (a). In addition, some parts of the ceiling are covered with uniform layers instead of pyramid arrays. 3 Methods The determination of the acoustic characteristics of the chamber is provided in accordance with ISO 3745:2012 / GOST-ISO 3745-2014 [ 25 , 20 ] . Pressure fields are generated by the omnidirectional sound source OED-SP360 with the amplifier OED-PA360. Measurements of spatial distributions of the sound pressure level (SPL) are performed with the sound level meter Bruel&Kjaer type 2250 and the microphone Sennheiser e604. The background noise and reverberation time measurements are conducted in points \text{b}_{1,2} and \text{r}_{1,2} , respectively, while the SPL measurements are carried out in several points located along 4 trajectories directed from the source to the corners of the camera, as shown in Fig. 1

Read the complete text