High Fidelity Single-NV Qubit Quantum State Tomography by Photoelectric Readout

Boo Carmans 1,2, Michael Petrov 1,2, Milos Nesladek 1,2 · 2026

Read High Fidelity Single-NV Qubit Quantum State Tomography by Photoelectric Readout by Boo Carmans 1,2, Michael Petrov 1,2, Milos Nesladek 1,2 (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-16502.txt.

Introduction

Carmans, Petrov, and Nesladek read out a diamond NV qubit's state with electric current. NV centers are strong room-temperature qubit candidates. Their spin is usually read by light emission. Optical readout needs microscope resolution, which blocks dense spin layouts. The team instead performs quantum state tomography with photoelectric readout. State fidelity reached 0.995, matching parallel optical measures. Photocurrent delays slow the method, and a model explains them.

Catalog record

CREATORBoo Carmans 1,2, Michael Petrov 1,2, Milos Nesladek 1,2
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE15682
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.16502

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

High Fidelity Single-NV Qubit Quantum State Tomography by Photoelectric Readout Boo Carmans 1,2, Michael Petrov 1,2, Milos Nesladek 1,2 Abstract Quantum computing is a rapidly developing field. However, the most commonly used qubits require cryogenic conditions to operate, which increases the costs and puts constraints on the up-scaling. Ambient solid-state qubits provide an alternative with potential for large-scale application. The nitrogen-vacancy (NV) center in diamond is one of the main candidates for solid-state computing architectures at room temperature and has proven to be competitive in terms of gate fidelity, quantum error correction, couplings, etc. Each NV center has an associated electronic spin that is conventionally read out by photoluminescence. However, regarding the creation of small, ambient NV-based quantum processors, the optical readout introduces limitations on the collection efficiency and resolution of the readout as well as the size of the final device and its integration into standard semiconductor architectures. In this work, we investigate the competitiveness of the photoelectric readout versus the traditional optical readout. In particular, we report on using photoelectrical detection to perform quantum state tomography measurements on a single NV center. We achieve the fidelity 0.995 ± 0.0062 0.995\pm 0.0062 for state reconstruction, comparable to optical measurements, demonstrating that the fidelity does not suffer from the adapted readout, highlighting the value of photoelectric detection for NV-based quantum processors. I Introduction The introduction of small, ambient processors as an alternative to conventional quantum architectures could significantly accelerate the development of quantum applications, as cooling or sustaining a vacuum are no longer required 1 . Ambient operation is possible for a certain number of solid-state defects that are found in wide bandgap materials such as diamond. The diamond lattice can host large dipole, photostable color centers 7 with the nitrogen-vacancy (NV) defect as one of the main candidates for quantum computing architectures. All necessary functionalities of a quantum computer have been demonstrated on the NV platform, such as quantum error correction 15 , couplings, quantum teleportation 9 , etc. For a single NV center, single qubit gates with a fidelity of 0.99995 and two-qubit gates with a fidelity of 0.992 have been demonstrated. 12 Nearby NV spin qubits can be entangled via their magnetic dipole-dipole interaction (strong coupling regime), which was demonstrated for both the electronic and nuclear spins of an NV pair separated by 25nm. 6 Currently, optical magnetic resonance (ODMR) is used as the main detection method of the NV spin state. An efficient scale-up of the technique is required for reading multiple spin qubits, as the optical resolution is limited by the Abbe limit, which is smaller than the interqubit distances that are required for dipolar NV spin entanglement. Secondly there is the low collection efficiency caused by the high refractive index of diamond and by the design of conventional detection optics. Both problems can be alleviated. The former by complex optical techniques 17 and the latter by microfabrication techniques 11 . An alternative solution is to use instead the photoelectric detection of magnetic resonance (PDMR) 2 . This method relies on the direct, on-chip electric detection of charge carriers that are excited from NV centers to the diamond conduction band by a two-photon process under optical pumping. The compatibility of this readout method with coherent manipulations of NV spin ensembles has been demonstrated 10 at ambient conditions and the readout contrast has been increased using dual-beam excitation 3 . It has also been successfully used to read out a single, coherently manipulated, electronic 14 and nuclear 8 spin, demonstrating its potential for qubit state detection. Compared to optical detection, the advantages are spatial resolution, detection rates, compactness, and integration with electronics 4 . The optical-to-electronic conversion of the photoluminescence signal is no longer required and the integration of NV-diamond with electronics is facilitated, paving the way to compact integrated systems. This work extends the photocurrent readout of NV centers to quantum state tomography. In particular, we perform Rabi phase quantum state tomography (RPQST) 13 on the electron spin of a single NV center at room temperature, and demonstrate that employing a photoelectric readout does not degrade the fidelity of state reconstruction significantly, compared to optical measurements. Across 21 measurements on a representative selection of pure states, the fidelity was 0.995\pm 0.0062 . The attained fidelities of individual measurements are compared to mathematical modeling and are approximately equal to those attained by conventional optical detection in 13 , indicating that using current readout introduces no significant error. With this work, we hope to have demonstrated that the photocurrent readout shall be a useful tool to measure spin states with high-fidelity in scalable NV spin registers, which are envisioned as a platform for fault-tolerant quantum computing. II Materials and Methods All measurements were performed on a home-built confocal setup that allows for simultaneous optical and electrical detection and is schematically depicted in figure 1 . The laser excitation originated from a yellow (561 nm) gem laser from Laser Quantum with a continuous-wave power tuned to 3.5 mW. For pulsed operation, the laser was focused onto an acousto-optic modulator (AOM) of type AOMO 3200-146 made by Crystal Technology, Inc. The light passed a a dichroic mirror (DM) of type DMLP567R from Thorlabs before being focused onto the sample by an air objective (×40, N.A. 0.95). That same DM allowed fluorescence (637 nm) from the NV centers to pass through towards the detector (a SPCM-AQRH-14 single photon counter from Excelitas Technologies), while blocking the strong laser light. Behind the DM was a FELH05550 Thorlabs long-pass filter with a cutoff wavelength of 550nm and a Thorlabs P30S pinhole to block the out-of-focus light, ensuring the detected photons mainly originated from the NV center. A high-pressure high-temperature (HPHT) diamond with N concentrations below 10 ppb was used as-bought (originating commercially from NDT). This is a type IIA diamond sample of electronic grade (111) surface that hosts single defect centers and small clusters. A MW antenna and a set of interdigitated electrodes (3.5 \mu m gap) were fabricated onto the diamond surface using optical lithography with sputtering deposition and consisted of a stack of a 20 nm layer of titanium covered with a 100nm layer of aluminium. For the application of MW pulses, an arbitrary wave generator (AWG) of model M8195A from Keysight was used together with a MW amplifier (ZHL-16W-43-S+, Mini-Circuits). The photocurrent detection used a suction voltage of approximately 2V/ \mu m delivered by the picoammeter/ voltage source Model 487 from Keithley, that was also used for current readout. Figure 1: Experimental setup with detail of printed circuit board containing diamond sample and connections to different devices. Electrodes can be seen on top of the diamond sample to collect the charge carriers for the photoelectric readout. Photoelectrical Detection of Magnetic Resonance (PDMR) 2 happens through a two-step process of excitation (first photon) and ionization (second photon), first bringing the electron into the excited state and then into the conduction band (CB). The free electron is then driven by an applied electric field and captured via electrodes fabricated on the diamond surface. The charge state of the NV - center switches to a neutral NV 0 complex. From the NV 0 center, the negative charge state can be recovered via absorption

Read the complete text