PulmoVec: A Two-Stage Stacking Meta-Learning Architecture Built on the HeAR Foundation Model for Multi-Task Classification of Pediatric Respiratory Sounds

Izzet Turkalp Akbasli, Oguzhan Serin · 2026

Read PulmoVec: A Two-Stage Stacking Meta-Learning Architecture Built on the HeAR Foundation Model for Multi-Task Classification of Pediatric Respiratory Sounds by Izzet Turkalp Akbasli, Oguzhan Serin (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-15688.txt.

Introduction

Akbasli and Serin validate a lung-sound pipeline with patients as the split unit. Each child gives many recordings, so record-level splits can leak. They study 19,693 doctor-marked events from 736 children in the SPRSound database. A frozen HeAR encoder with small adapters feeds stacked scores. Event recognition held up, with an AUC of 0.95 for screening. Disease-group guessing failed, with an AUC of 0.58 and accuracy below the majority rate. The authors urge patient-level splits in future lung-sound work.

Catalog record

CREATORIzzet Turkalp Akbasli, Oguzhan Serin
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE44388
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.15688

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

PulmoVec: A Two-Stage Stacking Meta-Learning Architecture Built on the HeAR Foundation Model for Multi-Task Classification of Pediatric Respiratory Sounds Izzet Turkalp Akbasli, Oguzhan Serin Abstract Background: Respiratory diseases are a leading cause of childhood morbidity and mortality, yet lung auscultation remains subjective and limited by inter-listener variability, particularly in pediatric populations. Existing AI approaches are further constrained by small datasets and single-task designs. We developed PulmoVec, a multi-task framework built on the Health Acoustic Representations (HeAR) foundation model for classification of pediatric respiratory sounds. Methods: In this retrospective analysis of the SPRSound database, 24,808 event-level annotated segments from 1,652 pediatric patients were analyzed. Three task-specific classifiers were trained for screening, sound-pattern recognition, and disease-group prediction. Their out-of-fold probability outputs were combined with demographic metadata in a LightGBM stacking meta-model, and event-level predictions were aggregated to the patient level using ensemble voting. Results: At the event level, the screening model achieved an ROC-AUC of 0.96 (95% CI, 0.95–0.97), the sound-pattern recognition model a macro ROC-AUC of 0.96 (95% CI, 0.96–0.97), and the disease-group prediction model a macro ROC-AUC of 0.94 (95% CI, 0.93–0.94). At the patient level, disease-group classification yielded an accuracy of 0.74 (95% CI, 0.71–0.77), a weighted F1-score of 0.73, and a macro ROC-AUC of 0.91 (95% CI, 0.90–0.93). Stacking improved performance across all tasks compared with base models alone. Conclusions: PulmoVec links event-level acoustic phenotyping with patient-level clinical classification, supporting the potential of foundation-model-based digital auscultation in pediatric respiratory medicine. Multi-center external validation across devices and real-world conditions remains essential. Corresponding Author: Izzet Turkalp Akbasli, MD Department of Pediatric Emergency Medicine, Hacettepe University Faculty of Medicine 06100 Sihhiye, Ankara, Turkey Email: [email protected] Telephone: +90 312 305 1350 ORCID: 0000-0003-3055-7355 Running Head: PulmoVec for Pediatric Respiratory Sounds Keywords: pediatric respiratory sounds, lung sound classification, foundation audio model, HeAR, transfer learning, stacking ensemble, LightGBM, digital auscultation, SPRSound INTRODUCTION Background and Motivation Respiratory diseases are among the leading causes of morbidity and mortality in children worldwide, with lower respiratory tract infections continuing to represent a major cause of hospitalization and death, particularly in low and middle-income countries [ 1 , 2 ] . Pneumonia, in particular, remains the major contributor to childhood mortality, accounting for 14% of all deaths in children under five years of age and causing 740,180 deaths in 2019; timely and accurate diagnosis has been shown to reduce mortality by up to 28% [ 1 ] . To support early and accurate diagnostic decision-making in children with respiratory disease, clinicians rely on lung auscultation, a clinical technique that involves identifying pathological patterns in respiratory sounds using a stethoscope and that has remained a fundamental skill for nearly two centuries [ 3 , 4 ] . Despite its longstanding clinical use, lung auscultation remains inherently subjective, and substantial variability in the interpretation of respiratory sounds can occur even among trained clinicians [ 5 ] . These difficulties are further amplified in pediatric populations, where patient cooperation is limited and respiratory physiology differs from that of adults [ 6 , 7 ] . Recent advances in digital stethoscopes and smartphone-based recording technologies now enable the acquisition, storage, and computational analysis of respiratory sounds, creating new opportunities for objective evaluation and automated diagnostic support [ 3 , 8 , 9 ] . Problem Statement The existing pediatric respiratory sound classification literature is characterized by notable limitations. Most studies rely on small, single-center datasets, and heterogeneity across recording devices, annotation protocols, and label taxonomies limits cross-study comparability [ 10 , 11 , 12 ] . Most current architectures employ single-task classifiers, which may not capture the full clinical complexity of respiratory sounds in children [ 3 , 11 ] . In this context, the central research question is as follows: can a foundation audio model trained through large-scale self-supervised learning recognize acoustic patterns in pediatric respiratory sounds in a clinically meaningful way, and can a multi-task stacking architecture improve upon the performance of existing single-task approaches? Research Gap and Objectives The recent emergence of self-supervised foundation audio models for health acoustics has opened new possibilities. One of the most influential is Health Acoustic Representations (HeAR), a large-scale foundation encoder trained on 313.3 million audio clips from roughly 3 billion YouTube videos, with demonstrated strength across multiple health acoustics tasks [ 13 ] . Despite this progress, most applications of HeAR rely on simple single-task classifiers, and research on multi-task stacking architectures for respiratory sound classification remains limited [ 14 , 15 ] . Recent reviews further highlight persistent gaps in explainability, external validation, and clinically meaningful label design [ 3 , 10 , 11 , 16 ] . To address these limitations, this study introduces PulmoVec, a two-stage architecture that leverages HeAR as a shared acoustic backbone and integrates three complementary task-specific base classifiers with a LightGBM stacking meta-model that incorporates demographic metadata. The system is designed to mirror a stepwise clinical decision-support workflow: first distinguishing normal from abnormal sounds, then identifying the specific sound pattern, followed by predicting the disease group associated with pathological patterns, and finally integrating acoustic outputs with clinical variables such as age, sex, and recording location to generate more clinically meaningful predictions. METHODS Study Design and Data Source This study is based on a retrospective analysis of the publicly available SPRSound pediatric respiratory sound database, collected using an electronic stethoscope at Shanghai Children’s Medical Center (SCMC) [ 17 ] . SPRSound provides both record-level and event-level annotations (Normal, Fine Crackle, Coarse Crackle, Wheeze, Wheeze&Crackle, Rhonchi, Stridor) with millisecond-precision timestamps, generated by 11 experienced pediatric physicians [ 17 ] . The database encompasses 16 distinct disease diagnoses; the detailed distribution of these diagnoses is provided in the supplementary material (Supplementary Table S1). Because this study used a publicly available, pre-anonymized dataset and involved no direct participant contact or access to identifiable private information, additional institutional review board approval and individual informed consent were not required for the present secondary analysis. Study design, analysis, and reporting were conducted in accordance with TRIPOD+AI recommendations, and the completed TRIPOD+AI checklist is provided in Supplementary Appendix 1. Data Curation Data curation was performed in three stages: (1) removal of potential duplicate recordings, (2) exclusion of recordings labeled as “Poor Quality” at the record level, and (3) exclusion of recordings lacking event-level annotations. There were no missing data in the final analytic dataset for the variables used in model development, including age, sex, recording location, and event-level labels; accordingly, no imputation procedures were performed. Segments labeled as “No Event” in event-level annotations were included in the Normal class, consistent with their clinical interpretation. The current expanded version of the SPRSound database was used. Audio Preprocessing and Feature Extraction All signals were resampled to 16 kHz mono and standardized to 2.0-second windows (zero-padded if shorter, center-cropped if longer). A 10% overlap margin was applied around event boundaries. Acoustic feature extraction was performed using the HeAR foundation audio model [ 13 ] , producing a 512-dimensional embedding vector for each clip. Base Classifier Architecture and Label Design Three task-specific base classifiers were constructed on the shared HeAR embedding space. The classification head architecture was identical across all models: a fully connected layer (512 to 256 neurons), nonlinear activation, dropout ( p=0.3 ), and an output

Read the complete text