LUMINA: A Multi-Vendor Mammography Benchmark with Energy Harmonization Protocol

Hongyi Pan, Gorkem Durak, Halil Ertugrul Aktas, Andrea M. Bejar, Baver Tutun, Emre Uysal, Ezgi Bulbul, Mehmet Fatih Dogan, Berrin Erok, Berna Akkus Yildirim, Sukru Mehmet Erturk, Ulas Bagci · 2026

Read LUMINA: A Multi-Vendor Mammography Benchmark with Energy Harmonization Protocol by Hongyi Pan, Gorkem Durak, Halil Ertugrul Aktas, Andrea M. Bejar, Baver Tutun, Emre Uysal, Ezgi Bulbul, Mehmet Fatih Dogan, Berrin Erok, Berna Akkus Yildirim, Sukru Mehmet Erturk, Ulas Bagci (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-14644.txt.

Introduction

Pan and co-authors release LUMINA, a multi-vendor mammography benchmark with an energy harmonization step. Open breast imaging sets stay small and short on vendor range. LUMINA holds 1,824 images from 468 patients across six systems. Labels are pathology-confirmed, with BI-RADS and density notes attached. High- and low-energy image styles both appear. A foreground-only alignment maps images to a low-energy reference. Two-view models beat single-view ones on diagnosis and related tasks, they report. Harmonization lifts scores further across vendors.

Catalog record

CREATORHongyi Pan, Gorkem Durak, Halil Ertugrul Aktas, Andrea M. Bejar, Baver Tutun, Emre Uysal, Ezgi Bulbul, Mehmet Fatih Dogan, Berrin Erok, Berna Akkus Yildirim, Sukru Mehmet Erturk, Ulas Bagci
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE32917
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.14644

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

LUMINA: A Multi-Vendor Mammography Benchmark with Energy Harmonization Protocol Hongyi Pan, Gorkem Durak, Halil Ertugrul Aktas, Andrea M. Bejar, Baver Tutun, Emre Uysal, Ezgi Bulbul, Mehmet Fatih Dogan, Berrin Erok, Berna Akkus Yildirim, Sukru Mehmet Erturk, Ulas Bagci Abstract Publicly available full-field digital mammography (FFDM) datasets remain limited in size, clinical annotations, and vendor diversity, hindering the development of robust models. We introduce LUMINA , a curated, multi-vendor FFDM dataset that explicitly encodes acquisition energy and vendor metadata to capture clinically relevant appearance variations often overlooked in existing benchmarks. This dataset contains 1824 images from 468 patients (960 benign, 864 malignant), with pathology-confirmed labels, BI-RADS assessments, and breast-density annotations. LUMINA spans six acquisition systems and includes both high- and low-energy imaging styles, enabling systematic analysis of vendor- and energy-induced domain shifts. To address these variations, we propose a foreground-only pixel-space alignment method (“energy harmonization”) that maps images to a low-energy reference while preserving lesion morphology. We benchmark CNN and transformer models on three clinically relevant tasks: diagnosis (benign vs. malignant), BI-RADS classification, and density estimation. Two-view models consistently outperform single-view models. EfficientNet-B0 achieves an AUC of 93.54% for diagnosis, while Swin-T achieves the best macro-AUC of 89.43% for density prediction. Harmonization improves performance across architectures and produces more localized Grad-CAM responses. Overall, LUMINA provides (1) a vendor-diverse benchmark and (2) a model-agnostic harmonization framework for reliable and deployable mammography AI. 1 Introduction Breast cancer is the most prevalent type of cancer and one of the leading causes of cancer-related deaths among women 34 ; 33 . Recent advances in deep learning have demonstrated the potential to improve diagnostic accuracy and detect subtle lesions that can be overlooked by human readers 29 ; 17 . However, training robust and generalizable models requires large-scale, high-quality datasets. In the mammography domain, publicly available datasets such as CBIS-DDSM 14 and INbreast 19 are limited in size and heterogeneity, restricting the development of artificial intelligence (AI) systems that can perform reliably across diverse clinical settings. This underscores the need for comprehensive mammography datasets that capture high-resolution images across multiple views, patient populations, and imaging systems. To address this gap, we introduce the LUMINA dataset along with a foreground-only pixel-space CDF alignment method that reduces vendor/energy appearance drift and consistently improves accuracy and AUC across three tasks. Figure 1 : Representative benign and malignant mammograms. Our contribution can be summarized as follows: • LUMINA dataset. Unlike prior resources that are single‑vendor or film‑based (e.g., CBIS‑DDSM, INbreast), LUMINA is explicitly multi‑vendor and energy‑annotated FFDM at 12–14‑bit depth, with pathology‑confirmed outcomes, per‑breast BI‑RADS, and density labels. This combination enables controlled stress‑tests for vendor/energy shifts and evaluation of single‑ vs. two‑view modeling at clinically used resolutions. Fig. 1 presents representative benign and malignant mammograms. • Foreground-only histogram harmonization. A simple, vendor-agnostic histogram matching that excludes background pixels and preserves lesion contrast. • Three-task benchmark with multi-view modeling. Unified evaluation on (i) pathology, (ii) BI-RADS risk grouping (binary and 3-class), and (iii) density; two-view models outperformed single-view for diagnosis, with EfficientNet-B0 reaching 93.61% AUC; EfficientNet-B0 also obtains the highest AUC (93.97%) for BI-RADS, and Swin-T yields the best AUC (89.10%) for density. • Harmonization improves models and attention. Foreground histogram matching consistently raises AUC/ACC across settings (Fig. 6 in Sec. 6.3 ) and yields more focal Grad-CAMs around suspicious regions (Fig. 7 in Sec. 6.3 ), indicating better localization of lesion-related signal. 2 Related Works Table 1 : Comparison of publicly available mammography datasets. Pathology BI-RADS Breast Acquisition Dataset Origin Patients Images Labels Assessment Density Technique MIAS 30 UK 161 322 Yes No No SFM DDSM 4 USA 2,620 10,480 Yes Yes Yes SFM CBIS-DDSM 14 USA 2,620 10,239 Yes Yes Yes SFM INbreast 19 Portugal 115 410 No Yes Yes FFDM VinDR-Mammo 22 Vietnam 5,000 20,000 No Yes Yes FFDM RSNA 6 USA 1,970 9,594 Yes Limited* Yes FFDM CMMD 5 China 1,775 3,728 Yes No No FFDM CDD-CESM 13 Egypt 326 1,003 Yes Yes Yes CESM KAU-BCMD 1 Saudi Arabia 442 1,774 No Yes No FFDM LUMINA (Ours) Turkey 468 1,824 Yes Yes Yes FFDM *RSNA provides simplified BI-RADS labels (0: follow-up, 1: negative, 2: normal) instead of the full BI-RADS scores from 0 to 6. Mammography datasets: The Mammographic Image Analysis Society (MIAS) database 30 , the Digital Database for Screening Mammography (DDSM) 4 , and its curated extension CBIS-DDSM 14 have been widely used in early computer-aided detection system development, providing digitized film mammograms with associated lesion annotations and pathology verification. However, these datasets contain relatively low-resolution screen-film mammography (SFM) scans, limiting their applicability to current clinical practice. To address these limitations, several institutions have released modern full-field digital mammography (FFDM) datasets such as INbreast 19 , VinDR-Mammo 22 , RSNA Screening Mammography 6 , Chinese Mammography Database (CMMD) 5 , CDD-CESM 5 , KAU-BCMD 1 . Despite recent progress, many existing mammography datasets face limitations, including small sample sizes, reliance on film-based scans, or incomplete integration of radiological and pathological labels. Compared with these resources in Table 1 , LUMINA provides high-resolution multi-view FFDM images with pathology-confirmed outcomes, expert-provided BI-RADS risk categories, and full breast density annotations. These allow LUMINA to fill critical gaps in existing datasets and establish a valuable benchmark for developing and evaluating AI algorithms in breast cancer imaging. Mammography classification: CNN-based studies adapted architectures such as AlexNet 20 , VGG 18 ; 24 , and ResNet 7 ; 23 for mammography classification, showing clear improvements over handcrafted features 9 ; 2 . More specialized designs, such as multi-view CNNs that jointly model cranio-caudal (CC) and mediolateral oblique (MLO) views, have further enhanced diagnostic performance 29 ; 17 . Recently, transformer-based architectures have been explored, leveraging self-attention mechanisms to capture long-range dependencies across mammographic views and regions 3 . Medical image harmonization: Harmonizing medical images across different scanners, acquisition protocols, and vendors is critical to enabling robust and generalizable AI systems in healthcare. Statistical approaches such as ComBat 21 employ an empirical Bayes framework to correct batch-effects for MRI images by adjusting location and scale parameters of extracted imaging features, and have been shown to significantly reduce inter-site variability while preserving biological signal. Deep learning approaches, such as HarmoFL 12 , further address feature drift by normalizing frequency domain amplitudes and guiding model convergence in federated learning setups across heterogeneous clients. How we differ: Prior mammography studies typically address one task (diagnosis or BI-RADS or density) within a constrained imaging domain, often single‑vendor FFDM or film‑based datasets. In contrast, LUMINA couples (i) multi‑vendor FFDM with energy metadata, (ii) unified evaluation across three clinically relevant tasks, and (iii) a foreground‑only, pixel‑space CDF alignment that reduces vendor/energy intensity drift while preserving lesion morphology. Unlike ComBat‑style feature harmonizers or federated normalization methods, our approach is model‑agnostic , runs as a lightweight pre‑processing step, and consistently improves AUC and attention localization across backbones (Fig. 6 in Sec. 6.3 ). We further report view‑ablations showing that two‑view models outperform four‑view configurations while maintaining parameter efficiency (Table 4 in Sec. 6.2 ). 3 LUMINA Dataset Introduction The LUMINA dataset is a curated collection of FFDM developed in collaboration with the University of Health Sciences, Prof. Dr. Cemil Tascioglu City Hospital, Istanbul, Turkey. It consists of 1,824 images from

Read the complete text