Beam Test of a SiPM-on-Tile ZDC Prototype with 5.3 GeV Positrons at Jefferson Laboratory
Miguel Arratia · 2026
Read Beam Test of a SiPM-on-Tile ZDC Prototype with 5.3 GeV Positrons at Jefferson Laboratory by Miguel Arratia (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-14167.txt.
Introduction
Preins and co-authors report a beam test of a small Zero Degree Calorimeter built for the future Electron-Ion Collider. The unit reads light from staggered tiles with silicon sensors and has 370 channels, near a tenth of the full design. A beam of 5.3 GeV positrons at Jefferson Laboratory gave the test data. The team checks energy response, shower shape, and how well hit spots are located, and sets each beside simulation. The results guide the final ePIC design.
Catalog record
| CREATOR | Miguel Arratia |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 21485 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.14167
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Beam Test of a SiPM-on-Tile ZDC Prototype with 5.3 GeV Positrons at Jefferson Laboratory Miguel Arratia Abstract We report on a beam test of a Silicon Photo-Multiplier (SiPM)-on-tile Zero Degree Calorimeter (ZDC) prototype developed for the future Electron–Ion Collider (EIC). The detector implements the staggered scintillator-tile geometry envisioned for the final detector and includes 370 instrumented channels, corresponding to 𝒪 ( 10 % ) \mathcal{O}(10\%) of the full ZDC. The detector was tested using a 5.3 GeV positron beam at Jefferson Laboratory. We measure the energy response, shower shape, and spatial reconstruction performance of the detector and compare these results with simulation. These studies provide key input for the optimization of the final ePIC ZDC design. 1 Introduction A key requirement for the physics program of the future Electron–Ion Collider (EIC) [ 2 , 1 ] is the precise detection of neutral particles emitted at very small angles with respect to the hadron beam. Within the ePIC detector [ 11 ] , the Zero Degree Calorimeter (ZDC) [ 17 ] plays a central role in this capability, enabling measurements of forward neutrons and photons. To meet these requirements, the ePIC ZDC is designed as a compact, high-granularity sampling calorimeter based on Silicon Photo-Multiplier (SiPM) on-tile technology. Its modular architecture allows access to sampling layers for periodic SiPM annealing, mitigating radiation-induced degradation [ 15 ] . SiPM-on-tile calorimetry employs plastic scintillator tiles coupled to individually instrumented SiPMs, enabling high transverse granularity and adaptable mechanical integration. These characteristics make the technology well suited for highly granular calorimeters and have motivated its adoption in several modern detector systems. Implementations have been studied extensively by the CALICE collaboration [ 21 ] and incorporated into the CMS High-Luminosity LHC calorimeter upgrade [ 23 , 10 , 8 ] . Within ePIC, related SiPM-on-tile designs are planned for multiple subsystems, including the high-granularity calorimeter insert [ 4 ] and the forward and backward hadronic calorimeters [ 7 ] , in addition to the ZDC. These design features were originally motivated by the requirements of particle-flow calorimetry [ 24 ] for proposed lepton collider detectors [ 14 , 9 , 16 , 12 , 13 ] . Validating this technology across the wide range of operating conditions expected at the EIC is a high priority for the experiment. Operating at pseudorapidities \eta>6 , the ePIC ZDC must achieve high energy and position resolution for electromagnetic and hadronic showers while remaining compact and accessible for servicing. The ZDC design employs an iron–scintillator sampling structure with small scintillator tiles instrumented with SiPMs, arranged in a staggered geometry that enhances transverse position resolution [ 17 , 18 ] . Demonstrating that this configuration meets performance expectations in beam conditions is a critical step toward final detector construction. This work builds on a sequence of previous SiPM-on-tile research and development efforts, including bench-top characterization of scintillator tiles and SiPMs [ 5 ] , a 40-channel beam test conducted at Jefferson Laboratory [ 3 ] , and a 192-channel prototype deployed in the STAR experimental hall at RHIC [ 26 ] . Together, these studies demonstrated the feasibility and scalability of the SiPM-on-tile approach in both controlled test-beam environments and collider-like conditions. After the measurements presented in this paper were completed, the same detector was exposed to radiation equivalent to one year of operation at the EIC, and it was shown that the detector could still be calibrated on a channel-by-channel basis under realistic radiation damage conditions [ 25 ] . We report a beam test of a 370-channel SiPM-on-tile ZDC prototype conducted at Jefferson Lab’s Hall D Pair Spectrometer in April 2025. The detector represents a significant scale-up relative to earlier prototypes, comprising 370 readout channels and implementing the staggered scintillator layout foreseen for the final detector. The test was conducted in the Hall D Pair Spectrometer (PS) using positrons with energies of approximately 5.3 GeV and accumulated 6.58 million events over the course of the run, with 98.7% of channels fully operational. The objectives of this test were to validate the ZDC detector concept and geometry, benchmark the detector response against simulations, and assess key performance characteristics, including energy resolution, spatial resolution, and shower shape. This study also provided operational experience with a ZDC-specific implementation of SiPM-on-tile technology and informs the ongoing optimization of the final ePIC ZDC design. 2 ZDC Prototype 2.1 Overview of Structure The ZDC prototype (Fig. 1 ), installed at Jefferson Lab in front of the Hall-D Pair Spectrometer, is a 15-layer SiPM-on-Tile sampling hadronic calorimeter. Each layer consists of a 5\times 5 array of square 48.8\,\text{mm}\times 48.8\,\text{mm}\times 4\,\text{mm} EJ-212 scintillating tiles, individually wrapped in reflective ESR foil and mounted on a custom PCB. Hamamatsu s14160-1315PS 1.3-mm SiPMs are soldered to the PCB, and the scintillating tiles are air-coupled to the SiPMs via a central dimple. The PCB routes the signals to adapter connectors that attach to the DAQ system via 28 AWG ribbon cables. As individual layers were being constructed, a series of quality assurance (QA) checks were performed to verify proper SiPM operation and signal integrity before integration into the full detector stack. The layers are interleaved with 20 mm thick steel plates (1.1 X_{0} ), with alternating layers shifted diagonally by half a cell width in each direction. In total, the detector was approximately 17 X_{0} long, and had the dimensions 28.7\,\text{cm}\times 29.5\,\text{cm}\times 61.0\,\text{cm} . The entire detector is housed within an 8020-bar frame wrapped with black-out fabric to act as a dark box. The DAQ system is set up on a platform beneath the detector. Figure 1 : The ZDC prototype installed at Jefferson Lab in front of the Hall-D Pair Spectrometer 2.2 DAQ and Trigger System The ribbon cables from the PCB layers are connected to six CAEN DT5202 units, linked via TDLink fiber optic cables to a CAEN DT5215 Concentrator Board, which connects to a DAQ laptop via USB, controlled remotely through RealVNC. The DRS4 trigger output is fed into an F_IN port on the concentrator, duplicated across six F_OUT ports. These trigger signals are distributed to the T0-IN ports of the six CAEN DT5202 units via LEMO cables. A diagram of the entire DAQ system is shown in Fig. 2 . Figure 2 : A diagram of the DAQ system for the ZDC prototype. The trigger system consists of two SENSL boards with 3-mm SiPMs, air-coupled to thin scintillating tiles aligned in-line. These are mounted in a 3D-printed holder shown in Fig. 3 , suspended from the iron structure’s top pins. The SENSL boards are biased at 29 V using a KETEK SiPM bias source in parallel. The SOUT signal is transmitted via SMA cables to a DRS4 digital multimeter, connected to a laptop via USB and controlled remotely through RealVNC. The DRS4 software is configured for AND logic between the two channels with a threshold of 5 mV (0.17 MIP). Figure 3 : The trigger system for the ZDC prototype. 3 Commissioning and Data Acquisition 3.1 Installation The ZDC prototype was installed at the Hall-D PS at JLab on April 23, 2025. After a series of QA checks, 370 of the total 375 channels were determined to be functional. All non-functional channels were located outside of the