Development of a high-field pulsed magnet and optical fiber coupled cryostat system for magneto-photoluminescence measurements
Deepesh Kalauni, Kingshuk Mukhuti, Tao Peng, Bhavtosh Bansal · 2026
Read Development of a high-field pulsed magnet and optical fiber coupled cryostat system for magneto-photoluminescence measurements by Deepesh Kalauni, Kingshuk Mukhuti, Tao Peng, Bhavtosh Bansal (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-13436.txt.
Introduction
Deepesh Kalauni and co-authors report a high-field pulsed magnet system with a fiber-coupled cryostat for magneto-photoluminescence work. A novel part is the use of electrolyte capacitors in a 75 kJ bank to drive the magnet. That design yields high fields at a low charging voltage of 400 V. The zylon reinforced wire wound coil reaches a peak field of 35 tesla with a 10 ms rise time. A 4 K helium closed-cycle cryocooler gives a stable cold setting down to 5 K.
Catalog record
| CREATOR | Deepesh Kalauni, Kingshuk Mukhuti, Tao Peng, Bhavtosh Bansal |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 28541 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.13436
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Development of a high-field pulsed magnet and optical fiber coupled cryostat system for magneto-photoluminescence measurements Deepesh Kalauni, Kingshuk Mukhuti, Tao Peng, Bhavtosh Bansal Abstract This paper presents the development of a high field pulsed magnet system combined with an optical fiber-coupled low temperature cryostat for magneto-photoluminescence measurements. A novel aspect of our system is the use of electrolyte capacitors in a 75 kJ capacitor bank to drive the pulsed magnet, enabling the generation of high magnetic fields at a relatively low charging voltage (400 V). The zylon reinforced wire wound magnet coil achieves a maximum field strength of 35 tesla with a magnetic field rise time of 10 ms. The integrated cryostat was developed to meet the specific requirements of magneto-photoluminescence experiments using a 4 K helium closed-cycle cryocooler to provide a stable low-temperature environment down to 5 K. I INTRODUCTION High magnetic fields combined with photoluminescence spectroscopy have emerged as essential tools for probing the fundamental physics of condensed matter systems, particularly in the investigation of excitonic phenomena and quantum states in low dimensional semiconductors. crooker2020gan ; gen2020crystalfield ; qiang2021polarized ; shornikova2025brightdark ; zhang2023dark ; shornikova2025bright ; serati2024probing ; mintairov2025dirac ; shornikova2020magneto ; Hayne2012_C2 Strong magnetic fields allow access to energy levels that are otherwise hidden, providing detailed insight into spin and valley physics, many-body interactions, and quantum correlations. Recent years have witnessed remarkable advances in understanding these phenomena through magneto-photoluminescence measurements, with studies demonstrating Landau quantization of excitons in monolayer transition metal dichalcogenides, liu2020landau the brightening of spin-forbidden dark excitons in MoS 2 and MoSe 2 monolayers, robert2020measurement and the observation of complex many-body states such as six-body and eight-body exciton complexes in WS 2 . vantuan2022sixbody These studies deepen our understanding of quantum phenomena and facilitate spintronic and valleytronic applications. Low temperature photoluminescence measurements are essential for resolving excitonic fine structure and quantum phenomena, as suppressing thermal broadening enables the separation of closely spaced energy levels. Moreover, reduced phonon scattering at low temperatures enhances the photoluminescence signal by minimizing non radiative recombination. Cong2015_Superfluorescence ; Bryja2004_MagneticExcitons ; Li2019_DarkExciton Conventional approaches to generating magnetic fields beyond \gtrsim 15 tesla, including superconducting and resistive DC magnets face significant limitations in accessibility, cost, and operational complexity. zhang202426 ; twin2007present ; Hollis ; chen2012resistive Indeed while high temperature superconducting solenoids have been demonstrated to reach beyond 26 tesla, typical laboratory superconducting magnets have been restricted to about 12–14 tesla, beyond which the cost becomes prohibitive. Pulsed magnets have long offered an effective alternative, achieving non-destructive fields exceeding 100 T. zherlitsyn2010design While the magnetic fields are transient, with pulse durations typically in the millisecond to second range, this timescale is well-suited for investigating condensed matter phenomena that occur on picosecond to microsecond timescales. High magnetic field user facilities worldwide have established magneto-photoluminescence measurements based on pulsed magnetic fields, however these systems typically rely on liquid helium cryostats, which require substantial resources and operational costs. han2017pulsed ; boebinger2001national ; tay2022magneto ; noe2013tabletop ; lncmp2006toulouse Closed-cycle refrigerators (CCR) offer a practical alternative by achieving temperatures down to 5 K without liquid cryogen consumption, with successful implementations demonstrated across diverse measurement techniques including magnetotransport, Mössbauer spectroscopy, NMR, and SQUID microscopy. murthy2007construction ; naumov2010closed ; berryhill2008novel ; goto2011optical ; low2021scanning In this paper, we report complete development of a high pulsed magnetic field system capable of reaching 35 T. Mukhuti-Bansal The system utilizes an electrolytic capacitor bank using a very low charging voltage of 400 V. This is in contrast to conventional pulsed magnets, which typically require voltages in the 3–12 kV range. Furthermore, the system is integrated with a cryogen-free closed-cycle refrigerator (CCR) designed to achieve temperatures down to 5 K at the sample stage, eliminating the need for liquid helium based cooling. To facilitate photoluminescence measurements within the narrow magnet bore, we have implemented a fiber optic coupling approach. This solution eliminates the need for free-space optics inside the magnet, significantly reduces alignment complexity, and prevents beam deflection caused by intense magnetic forces. Collectively, these advancements offer a robust platform for investigating the optical behavior of materials in high magnetic fields and cryogenic environments. Such facilities are usually available only at large national laboratories equipped with substantial resources and personnel. Kratz2002_C2 ; Herrmannsdoerfer2003_C2 ; Singleton2004_C2 ; Ortenberg2001_C2 ; Miura2001_C2 ; Bykov2001_C2 The work demonstrates that a sophisticated system within the constraints of a small laboratory space and budget can also be developed in small laboratories, albeit with a lower peak field. II The pulsed magnet II.0.1 The generation circuit The pulsed magnet is operated using modest a capacitive discharge circuit, shown in Fig. 1. Figure 1: (a) Schematic of the pulsed magnetic field generation circuit. (b) Magnetic field profiles recorded at various charging voltages. The inset in panel (b) shows the dependence of the peak magnetic field on the applied charging voltage. The capacitor bank comprises of 60 standard electrolytic capacitors (Alcon Electronics Pvt. Ltd. , India) connected in parallel, each with a capacitance of 10 mF, resulting in a total capacitance of 600 mF. The bank can be charged to a maximum of 500 V. During operation, the capacitors are first charged using a locally made high current unregulated dc power supply, connected to the bank through a high power 75 \Omega current limiting resistor. A changeover switch enables the same resistor to connect the capacitor bank to ground and to gently discharge the capacitors without firing the magnet, if needed. Once the bank is charged, the stored energy is rapidly discharged through the magnet coil by remotely triggering a thyristor, producing a transient magnetic field [Fig. 1(b)]. A crowbar diode prevents the current from oscillating and protects the electrolytic capacitors from damage by reverse charging. A high current double-pole double-throw switch is used for field reversal. The thyristor trigger (a current amplified 5 V TTL pulse connected to the thyristor via a 1:1 isolation transformer) is also used to synchronize the rest of the experiment. Table 1: Specifications of the magnet coil Parameter Value Inner bore size 18 mm Axial length 60 mm Coil conductor material Copper, 8-layer winding Wire length 13.6 m Mechanical reinforcement Zylon, 7 layers Inductance 0.138 mH Resistance at 300 K 23.71 m \Omega Resistance at 77 K 2.89 m \Omega Maximum magnetic field 35 T Stored energy at peak field 48 kJ Figure 2: Results simulated using the Pulsed Magnet Design Software (PMDS) at a peak magnetic field of 35 T. (a) Schematic of the designed magnet coil, (b) magnetic field profile, (c) radial heating distribution of the coil, and (d) stress distribution as a function of radial distance. II.0.2 The magnet coil Fig. 2(a) shows the schematic of the magnet coil. The coil is designed with a free inner bore of 18 mm to maximize the peak magnetic field under the constraints set the capacitor bank. With simulations performed using the Pulsed Magnet Design Software (PMDS), peng2008efficient ; herlach2006experimental ; vanacken2001pulsed 35 T was seen to be possible. Final design has a total of 15 winding layers, including 8 conductive layers and additional zylon reinforcement layers. The maximum achievable field in such a coil is limited by the ultimate tensile strength (UTS) of the materials used, as the conductor must withstand the substantial Lorentz forces produced by