Read DINOv3 with Test-Time Calibration for Automated Carotid Intima-Media Thickness Measurement on CUBS v1 by Zhenpeng Zhang, Jinwei Lu, Yurui Dong, Bo Yuan (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-13382.txt.
Introduction
Zhenpeng Zhang and co-authors test DINOv3 for carotid intima-media thickness measurement on ultrasound images. This thickness is a known marker for atherosclerosis and cardiovascular risk. Their pipeline segments the intima-media band, draws upper and lower boundaries column by column, and converts to physical units. Test-time threshold calibration cut the mean error a lot on a held-out set and drove bias toward zero. Scores across three patient-level splits put the method in a clinically relevant range, the team reports.
Catalog record
| CREATOR | Zhenpeng Zhang, Jinwei Lu, Yurui Dong, Bo Yuan |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 16722 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.13382
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
DINOv3 with Test-Time Calibration for Automated Carotid Intima-Media Thickness Measurement on CUBS v1 Zhenpeng Zhang, Jinwei Lu, Yurui Dong, Bo Yuan Abstract Carotid intima-media thickness (CIMT) measured from B-mode ultrasound is an established vascular biomarker for atherosclerosis and cardiovascular risk stratification. Although a wide range of computerized methods have been proposed for carotid boundary delineation and CIMT estimation, robust and transferable deep models that jointly address segmentation and measurement remain underexplored, particularly in the era of vision foundation models. Motivated by recent advances in adapting DINOv3 to medical segmentation and exploiting DINOv3 in test-time optimization pipelines, we investigate a DINOv3-based framework for carotid intima-media complex segmentation and subsequent CIMT measurement on the Carotid Ultrasound Boundary Study (CUBS) v1 dataset. Our pipeline predicts the intima-media band at a fixed image resolution, extracts upper and lower boundaries column-wise, corrects for image resizing using the per-image calibration factor provided by CUBS, and reports CIMT in physical units. Across three patient-level test splits, our method achieved a mean test Dice of 0.7739 ± \pm 0.0037 and IoU of 0.6384 ± \pm 0.0044. The mean CIMT absolute error was 181.16 ± \pm 11.57 μ \mu m, with a mean Pearson correlation of 0.480 ± \pm 0.259. In a held-out validation subset ( n = 28 n=28 ), test-time threshold calibration reduced the mean absolute CIMT error from 141.0 μ \mu m at the default threshold to 101.1 μ \mu m at the measurement-optimized threshold, while simultaneously reducing systematic bias toward zero. Relative to the error ranges reported in the original CUBS benchmark for classical computerized methods, these results place a DINOv3-based approach within the clinically relevant ∼ \sim 0.1 mm measurement regime. Together, our findings support the feasibility of using vision foundation models for interpretable, calibration-aware CIMT measurement. 1 Introduction Common carotid intima-media thickness (CIMT) is a long-established marker of vascular aging and subclinical atherosclerosis and has been widely used in epidemiologic studies, cardiovascular risk modeling, and longitudinal follow-up [ 1 , 2 , 3 , 4 , 5 ] . In routine practice, CIMT is obtained from B-mode ultrasound by identifying the lumen-intima (LI) and media-adventitia (MA) interfaces along the far wall of the common carotid artery and measuring the distance between them [ 6 , 7 , 15 ] . Manual tracing, however, is labor-intensive and subject to both inter-reader and intra-reader variability [ 15 , 18 ] , motivating the development of semi-automatic and fully automatic methods. Over the last two decades, carotid ultrasound segmentation and CIMT estimation have been approached using edge detectors, active contours, dynamic programming, fuzzy or probabilistic models, and, more recently, deep learning [ 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 ] . Despite substantial progress, many methods remain highly specialized, dataset-specific, or heavily dependent on handcrafted priors. In parallel, large-scale self-supervised visual encoders and transformer-based segmentation backbones have emerged as strong generic representations for dense prediction tasks [ 23 , 24 , 25 ] . These developments motivate exploring whether a DINOv3-style backbone can also support carotid intima-media analysis. Two methodological ideas are particularly attractive for carotid ultrasound: using a strong transformer encoder for dense prediction, and calibrating the inference procedure toward the downstream measurement endpoint rather than overlap alone. These ideas are especially relevant when the anatomical target is thin, the output must remain physically meaningful, and the final clinical variable of interest is thickness measured in micrometers. In this work, we formulate CIMT estimation as a segmentation-and-measurement problem using a DINOv3-based model on CUBS v1 [ 15 ] . Our study makes three contributions. First, we adapt a DINOv3 segmentation pipeline to the carotid intima-media band and evaluate it under patient-level splits. Second, we explicitly correct for image resizing by propagating the original calibration factor (mm/pixel) to the resized inference grid, thereby enabling measurement reporting in \mu m rather than only in pixels. Third, we introduce a simple test-time calibration procedure that selects the post-processing threshold to minimize CIMT error, aligning the decision rule with the final clinical measurement objective rather than with overlap alone. 2 Related Work 2.1 Carotid ultrasound segmentation and CIMT measurement Classical CIMT studies established the methodological foundations of carotid ultrasound acquisition, boundary delineation, and clinical interpretation [ 1 , 2 , 6 , 16 , 17 ] . Multiple reviews have summarized edge-based, snake-based, dynamic-programming, and probabilistic approaches for LI/MA segmentation [ 6 , 7 , 29 ] . Several semi-automatic and automatic systems have reported absolute CIMT error in the 0.1–0.2 mm range relative to expert tracings, although performance varies across acquisition protocols, image quality, and evaluation design [ 22 , 12 , 20 , 21 ] . The CUBS benchmark is especially relevant because it systematically compared five computerized methods against multiple expert readers on a shared multicenter dataset and released images, contours, and calibration factors publicly [ 15 ] . 2.2 Deep learning for carotid wall analysis Deep learning has also been explored for carotid wall and boundary analysis, including CNN-based boundary tracing, U-Net variants, and three-dimensional ultrasound wall segmentation [ 13 , 14 , 19 ] . In particular, Biswas et al. reported deep learning-based CIMT estimation with error on the order of 126 \pm 134 \mu m on a Japanese diabetic cohort, providing one of the most relevant points of comparison for data-driven CIMT systems [ 19 ] . 2.3 Vision foundation models and DINOv3 in medical imaging Foundation-style visual encoders have become increasingly important in medical imaging, both as generic pretrained backbones and as starting points for domain adaptation [ 27 ] . Our work adopts this broader motivation in a carotid ultrasound setting, using a DINOv3-style backbone for dense prediction and a test-time calibration stage targeted directly at the downstream measurement objective. 3 Materials and Methods 3.1 Dataset We used the CUBS v1 dataset released by Meiburger et al. [ 15 ] . CUBS contains 2176 longitudinal B-mode common carotid artery images from 1088 participants, acquired across Cyprus and Pisa, with corresponding LI and MA contours from multiple manual and computerized methods. For measurement analysis, CUBS additionally provides a calibration-factor (CF) file for each image, defining the physical pixel size in mm/pixel at the original image resolution. For ground-truth generation we used Manual-A1, the expert tracing considered the gold standard in the original CUBS publication. 3.2 Patient-level split protocol To avoid subject leakage across training, validation, and test, splitting was performed at the patient level based on the clin_XXXX identifier rather than at the image level. Three random seeds (42, 123, and 999) were used. For each seed, the 1088 participants were split into train/validation/test partitions, and test metrics were averaged across seeds. 3.3 DINOv3 segmentation model We used a DINOv3-based segmentation architecture derived from our recovered training pipeline. The encoder was vit_base_patch16_dinov3 from the timm ecosystem, followed by a lightweight convolutional segmentation head. All input ultrasound images were converted to grayscale, resized to 512\times 512 , repeated to three channels, and normalized with ImageNet mean and standard deviation. The optimization objective combined cross-entropy and Dice loss. For each seed, the model was trained for 60 epochs and the checkpoint with the best validation Dice was retained. 3.4 CIMT extraction and resize-aware unit