G. Fu, M. Mews, F. Scutti, P. Urquijo, E. Barberio, V. Bashu, L.J. Bignell, I. Bolognino, A. Cools, F. Dastgiri, A.R. Duffy, L. Einfalt, M. Froehlich, T. Fruth, M. Gerathy, M. Hancock, R. James, S. Kapoor, S. Krishnan, G.J. Lane, K.T. Leaver, D. Marcantonio, P. McGee, J. McKenzie, L. McKie, M.A. McLean, P.C. McNamara, L.J. Milligan, K.J. Rule, Z. Slavkovská, O. Stanley, A.E. Stuchbery, B. Suerfu, G.N. Taylor, E. van der Velden, A.G. Williams, Y. Xing, Y.Y. Zhong · 2026
Read Measurement of the cosmic muon flux at the Stawell Underground Physics Laboratory by G. Fu, M. Mews, F. Scutti, P. Urquijo, E. Barberio, V. Bashu, L.J. Bignell, I. Bolognino, A. Cools, F. Dastgiri, A.R. Duffy, L. Einfalt, M. Froehlich, T. Fruth, M. Gerathy, M. Hancock, R. James, S. Kapoor, S. Krishnan, G.J. Lane, K.T. Leaver, D. Marcantonio, P. McGee, J. McKenzie, L. McKie, M.A. McLean, P.C. McNamara, L.J. Milligan, K.J. Rule, Z. Slavkovská, O. Stanley, A.E. Stuchbery, B. Suerfu, G.N. Taylor, E. van der Velden, A.G. Williams, Y. Xing, Y.Y. Zhong (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-11981.txt.
Introduction
Fu and a large team of co-authors report the first cosmic muon flux measurement at the Stawell Underground Physics Laboratory. Eight plastic scintillator panels recorded the muons deep underground. Those panels form the core of the muon veto planned for the SABRE South experiment. The flux they found matches simulations closely. Its uncertainty is far smaller than the uncertainty of the models, which makes the result a firm check for future work.
Catalog record
| CREATOR | G. Fu, M. Mews, F. Scutti, P. Urquijo, E. Barberio, V. Bashu, L.J. Bignell, I. Bolognino, A. Cools, F. Dastgiri, A.R. Duffy, L. Einfalt, M. Froehlich, T. Fruth, M. Gerathy, M. Hancock, R. James, S. Kapoor, S. Krishnan, G.J. Lane, K.T. Leaver, D. Marcantonio, P. McGee, J. McKenzie, L. McKie, M.A. McLean, P.C. McNamara, L.J. Milligan, K.J. Rule, Z. Slavkovská, O. Stanley, A.E. Stuchbery, B. Suerfu, G.N. Taylor, E. van der Velden, A.G. Williams, Y. Xing, Y.Y. Zhong |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 35113 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.11981
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Measurement of the cosmic muon flux at the Stawell Underground Physics Laboratory G. Fu, M. Mews, F. Scutti, P. Urquijo, E. Barberio, V. Bashu, L.J. Bignell, I. Bolognino, A. Cools, F. Dastgiri, A.R. Duffy, L. Einfalt, M. Froehlich, T. Fruth, M. Gerathy, M. Hancock, R. James, S. Kapoor, S. Krishnan, G.J. Lane, K.T. Leaver, D. Marcantonio, P. McGee, J. McKenzie, L. McKie, M.A. McLean, P.C. McNamara, L.J. Milligan, K.J. Rule, Z. Slavkovská, O. Stanley, A.E. Stuchbery, B. Suerfu, G.N. Taylor, E. van der Velden, A.G. Williams, Y. Xing, Y.Y. Zhong Abstract We report the first measurement of the underground cosmic muon flux at the Stawell Underground Physics Laboratory. The measurement uses eight EJ200 plastic scintillator panels, equipped with Hamamatsu R13089 PMT pairs at the ends, which are the primary components of the muon veto system for the upcoming SABRE South experiment. The measured muon flux is f = ( 6.33 ± 0.04 stat ± 0.35 sys ) × 10 − 8 [ s − 1 cm − 2 ] . f=(6.33\,\pm\,0.04_{\rm stat}\,\pm\,0.35_{\rm sys})\times 10^{-8}\,[{\rm s^{-1}cm^{-2}}]. This measurement is in excellent agreement with simulations, with a relative uncertainty an order of magnitude smaller than the modelling uncertainty. 1 Introduction The Stawell Underground Physics Laboratory (SUPL) is a new underground research facility situated in Stawell, Victoria, Australia, and the first deep underground physics laboratory in the Southern Hemisphere. In the coming decade, it will host several particle physics experiments dedicated to detecting rare events, such as the upcoming SABRE South experiment [ 5 ] aiming at dark matter direct detection. This work describes the first physics milestone of the laboratory: the measurement of the cosmic muon flux. This baseline quantity is a crucial component of the environmental background affecting all the experiments that will be hosted at SUPL. For the SABRE South experiment, it additionally represents an in-situ test of its data acquisition system and data processing pipeline. SUPL is located 1025 m below ground, featuring a flat overburden. The laboratory is situated as an offshoot of the operationally active Stawell Gold Mine, at coordinates 37^{\circ}03^{\prime}38^{\prime\prime}\mathrm{S} , 142^{\circ}47^{\prime}59^{\prime\prime}\mathrm{E} with a surface elevation of approximately 275 m above sea level. The low cosmic ray and radioactivity environment offered by the laboratory is an essential requirement for the sensitive experiments it will host. However, natural radiation sources that produce neutrons and gamma rays will need to be well understood. This work measures the cosmic muon flux at SUPL. This measurement is performed using the muon veto system of the SABRE South experiment, arranged in the telescopic configuration, using approximately one year of data collected between 2024 and 2025. 2 Detector setup and data acquisition 2.1 Muon detector setup The muon veto system of the SABRE South experiment consists of eight 5 cm-thick Eljen EJ-200 plastic scintillator panels. Each panel has a sensitive area measuring 3000 mm in length, 400 mm in width, and 50 mm in depth. The panels will be arranged in a flat array covering 9.6 m 2 above the active volume of the experiment to tag and veto muon events. Each muon detector panel is coupled to two 2-inch round Hamamatsu R13089 photomultiplier tubes (PMTs), with one positioned at each end. This configuration provides optimal detection efficiency and enables muon position reconstruction using timing information from the two PMTs. The schematic of a muon detector panel is shown in Fig. 1 together with a PMT assembly. Each panel features diamond-milled edges, cast and polished faces, and an acrylic fishtail-shaped light guide, secured with EJ-500 optical cement. PMT adapters are glued to the other end of each light guide with WELDON-40 acrylic cement and fastened to the housing via flanges. The cavity between the PMT mount flanges and the adapters is filled with black Room Temperature Vulcanising (RTV) silicone sealant to ensure a proper seal. The PMTs are mounted to the adapters via the flanges, with EJ-560 optical pads and EJ-550 optical grease serving as the interface. A gasket between the two flanges ensures effective sealing and mechanical cushioning. To maximise light collection efficiency, each panel is wrapped in aluminium reflective foil. It is also wrapped with black vinyl to protect and prevent light leakage. The modules were constructed by Eljen Technology and shipped to Melbourne, where they were tested in a ground-level laboratory. A panel coupled to two PMTs is shown in Fig. 2 . Data collected above ground is used to measure the single-panel muon detection efficiency as described in Sec. 3.1 . Figure 1: Assembly of a muon detector panel from the SABRE South muon detector veto system. The picture is provided by Eljen Technology [ 8 ] . Figure 2: Muon scintillator panel under test in the above-ground laboratory at the University of Melbourne. The SABRE South muon veto system will feature scintillator panels arranged in the same plane. However, for the present study, these are placed in a telescope configuration, defined as an arrangement allowing the measurement of the incident muon angle. Two telescopes are configured with orthogonal orientations to each other. Each telescope comprises two layers 68.9 cm apart, each featuring pairs of scintillator panels positioned adjacent to each other. This setup is shown in Fig. 3 . While angular-dependent flux measurements are beyond the scope of this study, they will be documented in future studies from the SABRE South collaboration. Figure 3: (a) The muon detector configuration at SUPL for the muon flux measurements. Eight muon detector panels are deployed in two layers and two orientations. (b) A diagram of the muon telescope configuration for the muon flux measurement. All 16 Hamamatsu R13089 PMTs are connected to a 16-channel CAEN V1743 digitiser with a dynamic range of 2.5 V and a resolution of 12 bits. Each waveform is sampled at a rate of 3.2 GS/s, with a total of 1024 samples recorded over a time interval of 320 ns. Each event is followed by a 125 \mu s dead time period, as specified by the manufacturer, due to the analog-to-digital conversion process implemented by the digitiser. For each channel, the trigger threshold is set to 10 ADC, corresponding to 6.1 mV. All PMTs are powered by a CAEN SY5527 mainframe equipped with an A7435SN high-voltage (HV) board. Single-panel events are triggered by coincident signals between two channels corresponding to the same panel. The gate width for this trigger is 50 ns. However, multi-panel events require triggers between at least two single-panel events. The multi-panel trigger window is set to 120 ns. When multi-panel triggers are issued, the waveforms from all 16 channels are recorded for further analysis. 2.2 Environmental monitoring As part of the SABRE South experiment, a prototype slow control system has been developed as an integral part of the data quality assessment [ 17 ] . The prototype slow control system has been used for the measurement presented here. The system monitors various experimental conditions, including temperature, pressure, and seismic vibration. Figure 4 shows an example of temperature, pressure, and vibration data readings from October 2024 to March 2025, during which the slow control system was operational. Figure 4: Temperature (top), pressure (middle), and vibration trigger rate (bottom) data monitored by the SABRE South slow control system. 2.3 Data acquisition campaigns