First Axion Search Results of the SUPAX Prototype Experiment
Tim Schneemann 1, Hendrik Bekker 2,3,4, Dmitry Budker 2,3,4,5, Kristof Schmieden 6, Matthias Schott 6, Malavika Unni 3,4, Arne Wickenbrock 2,3,4 · 2026
Read First Axion Search Results of the SUPAX Prototype Experiment by Tim Schneemann 1, Hendrik Bekker 2,3,4, Dmitry Budker 2,3,4,5, Kristof Schmieden 6, Matthias Schott 6, Malavika Unni 3,4, Arne Wickenbrock 2,3,4 (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-10943.txt.
Introduction
Tim Schneemann and coauthors report the first axion search results from a prototype of SUPAX, a haloscope planned to hunt axion-like particles as dark matter candidates. The prototype ran a copper cavity at 2 K inside a 12 T magnetic field, probing axion masses around 34 micro-electronvolts. The data exclude axion-photon couplings above a stated limit near that mass and also rule out dark photons with kinetic mixing above a second stated limit.
Catalog record
| CREATOR | Tim Schneemann 1, Hendrik Bekker 2,3,4, Dmitry Budker 2,3,4,5, Kristof Schmieden 6, Matthias Schott 6, Malavika Unni 3,4, Arne Wickenbrock 2,3,4 |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24789 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.10943
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
First Axion Search Results of the SUPAX Prototype Experiment Tim Schneemann 1, Hendrik Bekker 2,3,4, Dmitry Budker 2,3,4,5, Kristof Schmieden 6, Matthias Schott 6, Malavika Unni 3,4, Arne Wickenbrock 2,3,4 Abstract The SUPerconduction AXion search experiment ( Supax ) is a future haloscope-type detector designed to probe axion-like particles (ALPs) as candidates for dark matter and solutions to the strong-CP problem in the mass range between 8 μ eV 8\,\mu\textrm{eV} and 30 μ \mu eV. In the course of the preparation of Supax , a prototype experiment was built and operated. Using a copper cavity, cooled down to a temperature of 2 K and operated in a magnetic field of 12 T, we probe axion masses around 34 μ eV 34\,\mu\textrm{eV} and exclude axion-photon couplings down to | g a γ γ | > 1.6 ⋅ 10 − 13 GeV − 1 \absolutevalue{g_{a\gamma\gamma}}>1.6\cdot 10^{-13}\textrm{GeV}^{-1} . The data was also used to exclude dark photons in the same mass range with a kinetic mixing parameter of χ > 1.4 ⋅ 10 − 12 \chi>1.4\cdot 10^{-12} . Details of the experimental setup and the analysis strategy are summarized in this paper. 1 Introduction The QCD axion is a hypothetical pseudoscalar particle originally proposed to resolve the strong CP problem in quantum chromodynamics (QCD) [ 15 , 28 , 27 ] , which questions why the strong interaction appears to be fine-tuned to guarantee CP conservation. Beyond this fundamental theoretical motivation, the axion also emerges as a compelling dark matter candidate [ 16 , 1 , 9 , 10 , 24 ] . Various cosmological models predict that axions produced in the early universe could constitute a significant fraction, or even the entirety, of the observed dark matter. These models also relate the axion mass to its relic abundance, with many simulations favoring masses in the range of a few tens of \mu eV and above [ 19 ] . A broad range of experimental strategies have been developed to search for axions, most of which exploit their predicted coupling to photons via the inverse Primakoff effect [ 17 ] . In this process, axions can convert into photons when interacting with a strong magnetic field, providing a basis for resonant detection schemes. Among the most promising and widely pursued techniques is the haloscope approach [ 22 ] . In a haloscope, axions from the galactic dark matter halo are expected to convert into microwave photons within a resonant cavity immersed in a strong magnetic field. The cavity is tuned to match the expected axion mass, maximizing the conversion signal. Several state-of-the-art experiments, such as ADMX [ 11 , 4 ] , HAYSTACK [ 29 , 5 ] , RADES [ 3 ] , QUAX [ 18 ] , and CAPP [ 12 , 2 ] have successfully employed this technique and continue to probe axion masses across different frequency bands. In this context, the SUPerconduction AXion search experiment ( Supax ) [ 7 ] is being developed as a next-generation haloscope at the University of Bonn. As a first step, a prototype experiment has been constructed and operated to test key components and evaluate system performance. The prototype employs a 14.1 T superconducting solenoid magnet, a precision-machined copper cavity with a quality factor of 5\cdot 10^{4} and a resonance frequency of 8.3 GHz, and a low-noise signal readout with transistor based amplifiers. The entire setup is operated at liquid helium (LHe) temperatures to minimize thermal noise and enhance sensitivity. In this paper, we present the design and first experimental results from the Supax prototype, laying the groundwork for the full-scale experiment. This paper is structured as follows. After a brief explanation of the expected signal in Sec. 2 the experimental setup is detailed in Sec, 3 . Data analysis and results are discussed in Sec. 4 , followed by an outlook to the next stages of the experiment. 2 Theoretical Background: Axion Signal in a Resonant Cavity Axions and axion-like particles (ALPs) are pseudoscalar fields a(x) predicted to couple weakly to photons via the Lagrangian term \mathcal{L}_{a\gamma\gamma}=-\frac{1}{4}\absolutevalue{g_{a\gamma\gamma}}\,a\,F_{\mu\nu}\tilde{F}^{\mu\nu}=\absolutevalue{g_{a\gamma\gamma}}\,a\,\mathbf{E}\cdot\mathbf{B}\,, (1) where \absolutevalue{g_{a\gamma\gamma}} is the axion-photon coupling constant, F_{\mu\nu} is the electromagnetic field strength tensor, \tilde{F}^{\mu\nu} is its dual, and \mathbf{E} and \mathbf{B} are the electric and magnetic fields, respectively. In the presence of a background magnetic field \mathbf{B}_{0} , this interaction leads to the conversion of axions into photons, which forms the basis for haloscope experiments. Assuming the standard cosmological halo model where axions with mass m_{a} play the role of cold dark matter [ 13 , 8 ] , the axion field can be approximated as a classical, spatially coherent oscillating background: a(t)=a_{0}\cos(m_a t) , where a_{0} is the amplitude, related to the local dark matter density \rho_{a} via \rho_{a}=m_{a}^{2}a_{0}^{2}/2 . Inside a resonant microwave cavity permeated by a static magnetic field \mathbf{B}_{0} , the axion field acts as a source term for Maxwell’s equations, inducing an oscillating electric field at the frequency corresponding to the axion mass. The resulting power deposited into a resonant mode of the cavity is [ 23 ] P_{\textrm{sig}}=\absolutevalue{g_{a\gamma\gamma}}^{2}\rho_{a}\frac{\beta}{\beta+1}\frac{1}{m_{a}}B_{0}^{2}VCQ_{\textrm{eff}}\eta\,\hbar^{2}c^{5}\varepsilon_{0}\,, (2) where B_{0} is the external magnetic field, V is the volume of the cavity, C is the form factor of the cavity mode, defined as C=\frac{\left|\int_{V}\mathbf{E}_{c}\cdot\mathbf{B}_{0}\,dV\right|^{2}}{VB_{0}^{2}\int_{V}\epsilon(\mathbf{x})|\mathbf{E}_{c}|^{2}dV}\,. (3) The form factor is a measure of the overlap of the external magnetic field with the electric field of the cavity mode \mathbf{E}_{c} , where \epsilon(\mathbf{x}) is the permittivity in the resonant cavity. Q_{\text{eff}} is defined as Q_{\text{eff}}=\min(Q_{L},Q_{a}) , where Q_{L} is the loaded quality factor of the cavity, and Q_{a}\sim 10^{6} is the effective quality factor of the axion signal due to its narrow energy spread, and \eta summarizes any experimental losses. The expected signal is a narrow-band, quasi-monochromatic peak centered at a frequency \nu_{a}=\frac{m_{a}c^{2}}{h} with a relative linewidth \Delta\nu/\nu_{a}\sim 10^{-6} , corresponding to the virial velocity distribution of dark matter particles in the galactic halo. The noise term is given by k_{B}T_{\text{sys}}=h\nu\left(\frac{1}{e^{h\nu/k_{B}T}-1}+\frac{1}{2}+N_{A}\right)\,, (4) where N_{A} is the noise from the amplifier, and T is the physical temperature of the system. The signal-to-noise ratio (SNR) for an integration time t is then calculated as \text{SNR}=\frac{P_{\text{sig}}}{k_{B}T_{\text{sys}}}\sqrt{\frac{t}{\Delta\nu}}\,, (5) where T_{\text{sys}} is the system noise temperature and \Delta\nu\sim\nu_{a}/Q_{a} is the bandwidth of the axion signal. Maximizing sensitivity thus requires a high magnetic field B_{0} , large cavity volume V , high-quality factor Q_{L} , and low system noise temperature T_{\text{sys}} . The Supax experiment is designed with these requirements in mind, targeting axion masses in the range 8\,\mu\text{eV}\lesssim m_{a}\lesssim 30\,\mu\text{eV} using tunable, superconducting cavities within a 12 T solenoidal magnetic field at 10 mK ambient temperature. The prototype experiment has been performed with B=12.1 T, T_{sys} =9.99 K at 2 K ambient temperature and a resonance frequency of 8.27 GHz. 3 Experimental Setup The basic principle of a haloscope experiment is schematically illustrated in Fig. 2 , where the axion conversion in a magnetic field within an electromagnetic cavity is shown. The resulting signal is amplified, converted to a lower-frequency band, and digitized. The resulting time-series is Fourier-transformed into the frequency domain and analysed for any excess power around the resonance frequency. This setup is implemented as a prototype of the Supax experiment located at the