Materials Acceleration Platform for Electrochemistry (MAP-E): a Platform for Autonomous Electrochemistry
Daniel Persaud, Mike Werezak, Mark Xu, Melyne Zhou, Frank Benkel, Xin Pang, Vahid Attari, Brian DeCost, Ashley Dale, Nicholas Senior, Gabriel Birsan, Jason Hattrick-Simpers · 2026
Read Materials Acceleration Platform for Electrochemistry (MAP-E): a Platform for Autonomous Electrochemistry by Daniel Persaud, Mike Werezak, Mark Xu, Melyne Zhou, Frank Benkel, Xin Pang, Vahid Attari, Brian DeCost, Ashley Dale, Nicholas Senior, Gabriel Birsan, Jason Hattrick-Simpers (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-09845.txt.
Introduction
Daniel Persaud and coauthors built MAP-E, a robot platform that runs corrosion tests with no human hands on the work. Corrosion testing is slow and varies with operator skill, starving data driven materials work of clean data. Robotic liquid handling and multichannel control pull corrosion metrics in parallel. Checked against a standard benchmark, the platform then mapped pH and chloride stability for stainless steel on its own.
Catalog record
| CREATOR | Daniel Persaud, Mike Werezak, Mark Xu, Melyne Zhou, Frank Benkel, Xin Pang, Vahid Attari, Brian DeCost, Ashley Dale, Nicholas Senior, Gabriel Birsan, Jason Hattrick-Simpers |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 32492 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.09845
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Materials Acceleration Platform for Electrochemistry (MAP-E): a Platform for Autonomous Electrochemistry Daniel Persaud, Mike Werezak, Mark Xu, Melyne Zhou, Frank Benkel, Xin Pang, Vahid Attari, Brian DeCost, Ashley Dale, Nicholas Senior, Gabriel Birsan, Jason Hattrick-Simpers Abstract Corrosion testing is slow, labor-intensive, and sensitive to operator technique, limiting the generation of large, high-quality datasets for data-driven materials discovery. We introduce the Materials Acceleration Platform for Electrochemistry (MAP-E), an autonomous, high-throughput system capable of performing parallel electrochemical experiments. MAP-E integrates robotic liquid handling, sample transfer, and multi-channel potentiostatic control and extract corrosion metrics without human intervention. Validation against an ASTM G61-analog benchmark demonstrates reproducibility, with a standard deviation of 76 mV in pitting potential across 32 automated measurements. The platform was then employed to autonomously construct pH–chloride stability diagrams for 304 stainless steel using an uncertainty-driven sampling strategy on a Gaussian Process surrogate model. This approach reduces operator involvement and accelerates the exploration of environmental spaces. MAP-E establishes a framework for autonomous electrochemical experimentation, enabling generation of corrosion datasets that inform materials discovery, alloy design, and durability assessment in service environments. 1 Introduction The corrosion of metals and alloys remains a major challenge in ensuring the safety and reliability of infrastructure, transportation, and energy systems [ 5 , 19 , 42 ] . During service, materials are exposed to a diverse range of complex environments that can accelerate degradation, leading to significant safety concerns and as a results, substantial economic cost [ 16 , 23 , 24 , 3 , 19 , 42 , 31 ] . Predicting how materials will perform under different service conditions, or designing new materials with improved corrosion resistance for specific environments, requires an understanding of the complex interplay between alloy chemistry, microstructure, surface condition, and environmental factors [ 27 , 17 , 7 ] . This multifaceted nature makes the systematic exploration of corrosion phenomena experimentally demanding, especially because traditional electrochemical experiments are labor-intensive and sensitive to procedural details, requiring considerable experience to achieve reproducible results [ 42 , 18 ] . As a result, generating large, high-quality datasets that capture corrosion behavior across broad parameter spaces is challenging, limiting the ability to establish predictive relationships between material properties, environment, and degradation mechanisms. Autonomous electrochemical platforms have the potential to address these challenges by integrating networked instrumentation, modular fluid handling, and parallelized electrochemical cells under unified control software [ 39 , 31 , 28 ] . When coupled with machine learning (ML), these systems can be used to generate high-quality, informative data that enable systematic exploration of complex experimental spaces and discovery of underlying patterns. The standardized data produced can be shared with the broader research community, enabling others to develop predictive models, identify promising research directions, and collaborate to accelerate innovation across the field. Recent years have seen substantial progress in high-throughput (HT) electrochemical platforms, including systems that integrate hardware and software to enable varying degrees of autonomous operation. Early HT approaches emphasized parallel screening to maximize throughput, often relying on shared electrolytes, reduced solution volumes, simplified electrode configurations, or measurements limited to post-exposure or optical characterization [ 32 , 40 , 41 , 37 , 15 ] . More recent efforts have shifted toward increased autonomy through integrated hardware–software platforms, commonly based on scanning droplet cells or gantry-based systems that sequentially position a shared reference and counter electrode into electrolyte-filled wells [ 22 , 10 , 29 , 35 , 20 , 34 , 36 , 1 , 9 , 12 ] . Despite these advances, most platforms face trade-offs: systems closer to autonomy often perform experiments serially, limiting exploration speed, whereas parallelized systems frequently compromise on experimental fidelity, restricting their relevance for corrosion science. These accommodations are typically driven by constraints in hardware, cost, or the complexity associated with linking multiple pieces of equipment [ 8 , 2 ] . Collectively, these limitations define a critical gap for corrosion research: the absence of a platform that can perform parallel electrochemical measurements, using traditional cell geometries, electrolyte volumes, and standard electrode configurations, features necessary for high-quality data-driven exploration across diverse material-environment combinations. To address this gap, we have developed the Materials Acceleration Platform for Electrochemistry (MAP-E), a flexible, HT platform designed for autonomous electrochemical experiments. It integrates eight individually addressable electrochemical cells, each capable of performing independent measurements in parallel. The platform features modular fluid handling, enabling exploration of a wide range of aqueous environments. Robust component control and scheduling software manages complex experimental campaigns, enabling autonomous operation. By generating standardized electrochemical data, the MAP-E serves as a foundation for applying ML algorithms to autonomously explore complex experimental spaces. In this work, we first validate the MAP-E’s ability to perform reproducible electrochemical measurements using a modified testing protocol derived from an established corrosion standard. We then demonstrate its capacity to autonomously construct information-rich stability diagrams within a single closed-loop campaign, enabling more efficient use of experimental resources and operator time than traditional sequential approaches. By running eight cells in parallel, MAP-E achieves an immediate eightfold increase in throughput. Once the initial stock solutions are prepared, the system mixes and explores a broad environmental grid without further human intervention, enabling unattended execution of experimental campaigns. An uncertainty-driven acquisition strategy is used to adaptively select subsequent experimental conditions based on the model’s posterior predictive uncertainty. This focuses sampling on regions where the model is least certain, allowing informative areas of the design space to be explored efficiently under a constrained experimental budget. With these capabilities, MAP-E provides a framework for reproducible, data-driven exploration of corrosion phenomena and supports scalable generation of high-quality electrochemical datasets, enabling broader collaboration and innovation across the electrochemistry community. 2 Methods The design philosophy of the MAP-E centers on maximizing experimental throughput while minimizing the trade-offs in versatility and flexibility that commonly constrain automated or autonomous electrochemical platforms. Prior to operation, stock solutions are prepared to span the target environmental range, and polished samples are loaded into dedicated sample racks. A high-level software interface accepts experiment requests which specify the electrochemical methods, sample selection, and environmental conditions. Once initiated, MAP-E automatically orchestrates the full workflow. The system loads samples into the electrochemical cells, mixes and dispenses the target electrolyte compositions via the liquid-handling system. It executes the prescribed electrochemical measurements, and processes the resulting data to extract the corrosion parameters of interest while the system cleans the cells and prepares for the next round of experiments. The following sections describe the hardware, control software, and modeling framework for the autonomous stability diagram investigation. 2.1 Hardware The MAP-E hardware is organized into four subsystems that enable automated, HT electrochemical experiments: (1) the electrochemical cell array, (2) gantry system, (3) liquid handling, and (4) the potentiostat. The electrochemical array consists of eight custom, independently addressable flat cells, constructed from a cylindrical polycarbonate body with two machined end caps (one cell is shown in Figure 1(a) ). Each cell incorporates a platinum mesh counter electrode mounted within the rear end cap housing and a 1 cm 2 exposure window sealed with a Viton o-ring in the front end cap, defining a 25 mL electrolyte volume that meets the 0.2 mL/mm 2 minimum ratio recommended by ASTM G31 [ 38 ] . A pneumatic cylinder mounted