Electromagnetically induced transparency and population repump readout of Rydberg states of Cs atoms in a J-scheme

Noah Schlossberger, Christopher L. Holloway, Erik McKee, Michael A. Highman, Nikunjkumar Prajapati · 2026

Read Electromagnetically induced transparency and population repump readout of Rydberg states of Cs atoms in a J-scheme by Noah Schlossberger, Christopher L. Holloway, Erik McKee, Michael A. Highman, Nikunjkumar Prajapati (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-08678.txt.

Introduction

Noah Schlossberger and colleagues sense radio fields with Rydberg atoms using only plain diode lasers. A three-photon coupling scheme drops the doubling crystal and tapered amplifier that usually gate miniaturization. In the low-power regime the line stays thin, and the setup detects a 4.7 GHz field with sensitivity matching two-photon schemes. A repump readout variant reads the transparency in the other lasers through a separate state.

Catalog record

CREATORNoah Schlossberger, Christopher L. Holloway, Erik McKee, Michael A. Highman, Nikunjkumar Prajapati
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE16251
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.08678

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Electromagnetically induced transparency and population repump readout of Rydberg states of Cs atoms in a J-scheme Noah Schlossberger, Christopher L. Holloway, Erik McKee, Michael A. Highman, Nikunjkumar Prajapati Abstract Rydberg atom electrometry offers traceable electric field measurements over many decades of radio frequencies in a single device. Miniaturization of these sensors is primarily limited by requirements of the lasers used. Here we demonstrate a three-photon sensing scheme using a J-shaped energy level coupling that can be achieved using external cavity diode lasers, without the need for a doubling crystal or tapered amplifier. In the low laser power regime, we demonstrate a full-width at half-maximum linewidth of 1.3 MHz. We demonstrate that for RF field electrometry using conventional heterodyne techniques, we can detect 4.7 GHz at a sensitivity of 27 μ \mu V m -1 Hz -1/2 , comparable to that of two-photon detection schemes which require the use of a tapered amplifier. We also investigate a modified scheme where the probe laser is locked to a different hyperfine state, thus measuring the two-photon electromagnetically induced transparency in the other two lasers via the change in population of this separate state due to repumping. In this scheme we find the sensitivity for a 4.7 GHz field to be 39 μ \mu V m -1 Hz -1/2 , and demonstrate that the amplitude scaling with probe power offers a different saturation profile than the linked J-scheme counterpart. I Introduction Rydberg atoms have emerged as a powerful tool for SI-traceable, broadband electrometry Sedlacek et al. 2012 ; Holloway et al. 2014 ; Jing et al. 2020 ; Tu et al. 2024 ; Schlossberger et al. 2024a . These sensors are laboratory-setting instruments, with deployability largely limited by the making of chip-scale lasers at the relevant wavelengths Xing et al. 2025 . To reach the powers required at these wavelengths, frequency-doubling cavities and tapered amplifiers are often required Abel et al. 2011 ; Mohapatra, Jackson, and Adams 2007 ; Hill et al. 2022 . Here, we present a three-photon readout scheme for which all three wavelengths can exist as standard external-cavity diode lasers without the need for these frequency doublers and tapered amplifiers. We use only a fiber amplifier for the near-infrared coupling laser, which can be compact and inexpensive. A similar energy level scheme was recently demonstrated Ravi et al. 2025 in Rb, and here we demonstrate and characterize the scheme in Cs. We characterize the linewidth of the resonant three-photon feature and its sensitivity for electrometry of radio-frequency fields. We also demonstrate a measurement scheme that utilizes a decay to couple a two-photon Rydberg ladder to the probe rather than a direct three-photon coherence. In this readout scheme, the observed spectral feature comes from population repumping of the ground state. We characterize the sensitivity of the repump readout and compare its linewidth and amplitude to its resonant three-photon counterpart. II EIT readout The scheme utilizes a “J”-shaped chain of lasers to probe the energy of the Rydberg state. The energy level diagram is shown in Fig. 1 a. Figure 1: The “J”-shaped electromagnetically induced transparency scheme. a The energy level diagram of the measurement scheme. b The configuration of the lasers’ k -vectors. The direction of the beams (Fig. 1 b) is chosen to minimize the the Doppler k-vector mismatch, given by |\sum_{i}s_{i}k_{i}|=\\ \left|(-1)\left(\frac{2\pi}{895\textrm{ nm}}\right)+(1)\left(\frac{2\pi}{465\textrm{ nm}}\right)+(1)\left(-\frac{2\pi}{1060\textrm{ nm}}\right)\right|\\ =0.6~\mu\text{m}^{-1} (1) where k_{i} is the signed k -vector along the axis of the beams. The parameter s_{i} is either \pm 1 , where the plus sign indicates that the energy has increased going from one state to the other and a minus sign indicates the energy has decreased going from one state to the other. In our case, we start at 6P 1/2 , s_{i}=-1 going from 6P 1/2 to 6S 1/2 (the probe line), and s_{i}=1 for both the dressing and coupling lines. This residual k -vector is a factor of eight lower than that of a counter-propagating 852 nm and 510 nm two-photon scheme Zhao et al. 2009 which has a residual k -vector of 4.9 \mu m -1 . The probe frequency is locked to a saturated absorption spectrum in a reference cell, the dressing laser frequency is locked to a two-photon co-propagating EIT spectrum between the probe and dressing in a reference cell, and the coupling laser frequency is scanned to read out the Rydberg state. The transmission of the probe beam is read out on a photodetector. II.1 Linewidth To optimize the linewidth, the laser Rabi rates must be reduced such that they are not the dominating broadening effect. The parameters of the lasers are given in Table 1 . laser power ( \mu W) FWHM (mm) \Omega ( 2\pi\times\text{MHz} ) probe 1.3 1.6 2\pi\times 0.72 dressing 17 2.2 2\pi\times 0.26 coupling 460 2.4 2\pi\times 0.17 Table 1: Laser parameters used for narrow EIT linewidth. To compensate for the correspondingly small signal at these low laser powers, we use an optical chopper wheel to modulate the dressing light and perform lock-in detection of the probe transmission to achieve adequate signal-to-noise ratio (SNR). We also wrap the vapor cell in high permeability magnetic shielding, as background magnetic fields can cause spectral broadening on the order of MHz. Schlossberger et al. 2024b With this, we scan the coupling laser detuning \Delta_{c} from its resonance and monitor the change in probe transmission. The frequency axis scaling of the coupling detuning is calibrated with an ultra-stable cavity by referencing the spacing of cavity resonances between two electro-optic modulator sidebands that differ in frequency by 1.00 MHz. The resulting spectral lineshape is shown in Fig. 2 . Figure 2: Lineshape of the three-photon transparency on the 50D_{5/2} state in the low-power regime. We fit the lineshape to a Lorentzian with a full-width at half-maximum (FWHM) linewidth of 1.32\pm 0.06 MHz. This linewidth is still likely power-broadening-limited, but further reduction in laser powers is limited by SNR constraints. However, it is still well below the two-photon linewidth limit for energy resolution of the Rydberg state Schlossberger et al. 2026 . II.2 Electrometry and sensitivity We now consider this technique as a method for electrometer of radio-frequency (RF) fields. We remove the magnetic shielding to allow RF to enter the cell. We detect the RF field with a heterodyne detection scheme as in Refs. Gordon et al. 2019 ; Jing et al. 2020 . While low power regime shown in the previous section gives narrow lines, it gives poor SNR. The sensitivity, proportional to the slope of the spectral feature, is optimized for higher laser powers. The height of the feature can be improved by over an order of magnitude in exchange for a factor of a few in linewidth, meaning the slope can be enhanced with more laser power. We find the optimized regime to be powers of 18 \mu W, 380 \mu W and 419 mW for the probe, dressing, and coupling lasers, resulting in Rabi rates of 2\pi\times 2.7 MHz, 2\pi\times 1.2 MHz, and 2\pi\times 5.13 MHz respectively. At these powers, we measure the sensitivity of the 53D_{5/2}\rightarrow 54P_{3/2} transition in Fig. 3 . a b Figure 3: Sensitivity measurement of the system on the 4.7 GHz 53D_{5/2}\rightarrow 54P_{3/2} transition. a The Autler-Townes

Read the complete text