Fast array-based particle coincidence detection in a TimePix3-based velocity map imaging instrument Preprint: AIP/123-QED
Ian Gabalski, Eleanor Weckwerth, Chuan Cheng, Philip H. Bucksbaum · 2026
Read Fast array-based particle coincidence detection in a TimePix3-based velocity map imaging instrument Preprint: AIP/123-QED by Ian Gabalski, Eleanor Weckwerth, Chuan Cheng, Philip H. Bucksbaum (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-04942.txt.
Introduction
Ian Gabalski and team present a fast algorithm for particle coincidence finding in a TimePix3 speed map imaging instrument. The TimePix3 camera localizes many simultaneous hits in space and time, but its sparse stream makes grouping pixels into hits hard. Their centroiding method exploits data thinness to localize hits within a single pixel, and it runs on a GPU. Processing runs about 25 times faster than acquisition at 1 kHz, and the detector beats delay-line anode detectors at separating simultaneous hits.
Catalog record
| CREATOR | Ian Gabalski, Eleanor Weckwerth, Chuan Cheng, Philip H. Bucksbaum |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 39071 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2603.04942
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Fast array-based particle coincidence detection in a TimePix3-based velocity map imaging instrument Preprint: AIP/123-QED Ian Gabalski, Eleanor Weckwerth, Chuan Cheng, Philip H. Bucksbaum Abstract With the development of high repetition rate laser sources and advanced multi-particle correlation analyses such as covariance mapping, particle detection techniques such as velocity map imaging (VMI) are poised to offer unprecedented views into molecular phenomena. Taking full advantage of the high count rates in these experiments requires the development of detectors with sufficient spatial and temporal resolution that can process data in real time. The TimePix3 camera (TPX3CAM) is an event-based pixel detector capable of spatio-temporally localizing many simultaneous particle hits in an efficient manner. While the sparse nature of the data stream allows for compact representation of particle hits, it also presents algorithmic and computational challenges for clustering individual pixels into hits. Here we present the theory and application of a rapid data processing and centroiding algorithm for ion and electron hits collected in a VMI instrument. The array-based computations that comprise the algorithm take full advantage of the data sparsity of the TimePix3 data stream and localize particle hits on the microchannel plate (MCP) to better than a single pixel on the pixel detector. Centroiding can be parallelized on a commercially available graphics processing unit (GPU) for additional speed. Using these innovations, data processing occurs about 25 times faster than data acquisition, for a 1 kHz repetition rate instrument and tens of particles per shot. In addition to its speed, the TPX3CAM detector outperforms state-of-the-art delay line anode detectors at discriminating multiple simultaneous hits, enabling high-fidelity coincidence and covariance studies in the near future. I Introduction Velocity map imaging (VMI) spectroscopy Eppink and Parker 1997 ; Chandler and Houston 1987 is a powerful and widely used technique for resolving the momentum and angular distributions of charged particles produced in photo-induced processes. VMI detectors enable reconstruction of the three-dimensional momentum of each ion following a molecule’s interaction with a sequence of laser pulses using position- and time-sensitive detection. Coincidence detection schemes, in which multiple ions produced in the same event are detected simultaneously, can further provide access to the complete kinematic information of a photo-induced process. When the molecular charge state is high enough, as is typically the case in strong-field- or X-ray-induced multiple ionization, the Coulomb explosion of the charged photofragments can be used to infer the instantaneous molecular geometry. Burt et al. 2017 ; Allum et al. 2018 ; Hasegawa, Hishikawa, and Yamanouchi 2001 ; Bhattacharyya et al. 2022 ; Boll et al. 2022 ; Rudenko et al. 2017 ; Unwin et al. 2023 ; Bisgaard et al. 2009 VMI techniques can likewise be used to collect the photoelectrons produced by the ionizing pulse, Gabalski et al. 2023 ; Faccialà et al. 2025 ; Horton et al. 2019 the energies and angular distributions of which provide information on the underlying molecular states and the properties of the photoionization process itself. Geßner et al. 2006 ; Hockett et al. 2011 ; Gabalski et al. 2023 Both electron and ion VMI techniques can be combined in a single experiment to produce a complete picture of the laser-induced molecular process. Lehmann, Ram, and Janssen 2012 ; Zhao, Sándor, and Weinacht 2017 ; Cheng et al. 2020 ; Erk et al. 2018 ; Jin et al. 2025 VMI spectroscopy is thus a powerful tool for investigating ionization, photoexcitation, and photodissociation dynamics. Vredenborg, Roeterdink, and Janssen 2008 ; Ladda et al. 2025 Many of the processes that VMI is well suited to study, such as enhanced strong-field ionization, isomerization, molecular elimination, and nonsequential double ionization, Howard et al. 2023 ; Wells et al. 2013 ; Li et al. 2025 ; Weber et al. 2000 occur with low probability and therefore require large data sets to obtain reliable statistics. In recent years, the repetition rates of available ultrafast laser systems have steadily increased, which has enabled the study of low-yield or highly complex processes that were previously inaccessible. Tschentscher 2023 ; Leshchenko et al. 2020 ; Heuermann et al. 2023 ; Meier et al. 2024 ; Luu et al. 2018 ; Köttig et al. 2017 ; Brahms and Travers 2023 ; Golibrzuch et al. 2025 ; Nitz et al. 2025 In parallel, covariance mapping techniques permit operation in high count rate regimes by extracting particle correlations even when multiple competing channels are present. Frasinski, Codling, and Hatherly 1989 ; Frasinski 2016 ; Pickering et al. 2016 ; Allum et al. 2021 ; Cheng et al. 2023 Together, these advances have provided access to processes that occur only rarely and were previously beyond experimental reach by allowing substantially more data to be collected in a shorter period of time. With these new capabilities comes a growing need for detection techniques and data processing pipelines that can keep pace with increasing data collection rates while maintaining spatial and temporal resolution of particle hits. The particle detection mechanism of a VMI instrument consists of a microchannel plate (MCP) paired with either a phosphor screen or delay line anode (DLA) detector. The MCP amplifies the signal generated by each incident particle, converting it into an electron cascade that can be efficiently detected. Wiza 1979 DLA detectors provide precise spatial localization and timing information of amplified particle hits by measuring the timing of electrical signals from crossed, overlapping wire grids. Jagutzki et al. 2002a ; Lampton, Siegmund, and Raffanti 1987 ; Jagutzki et al. 2002b They are capable of high throughput by performing much of the signal processing in fast analog electronics, making them well suited for true coincidence measurements at high repetition rates. However, DLA detectors are fundamentally limited in their ability to operate in the covariance regime, where high particle event rates lead to detector saturation and ambiguity in hit assignment. State-of-the-art DLA detectors can localize simultaneous hits that are separated by several millimeters on the MCP, but they fail to distinguish hits that fall within this range. Jagutzki et al. 2002a In contrast, optical detection using a phosphor screen enables simultaneous localization of many particles with high spatial resolution, making it better suited for experiments with high count rates. This approach shifts much of the data processing burden to software and often requires specialized data treatment for full three-dimensional momentum reconstruction Lee et al. 2014 or else selects a particular ion time-of-flight range via electrical gating of the MCP. Townsend, Minitti, and Suits 2003 While the superior multi-hit resolving capabilities of optical detectors has motivated their use in VMI instruments, they struggle to keep pace with the multi-kHz repetition rates of modern laser systems. These considerations have motivated the development and adoption of pixelated optical detectors capable of recording individual particle hits at high rates. One such detector is the TPX3CAM, an event-based optical camera with a temporal resolution of 1.5 ns that reports events over threshold from individual pixels. Frojdh et al. 2015 Unlike conventional frame-based cameras, the TPX3CAM records data only when the signal in a pixel reaches a threshold, producing a sparse data stream where only pixels associated with particle hits are recorded. This allows the TPX3CAM to be used at high count and repetition rates without producing overwhelming amounts of data, as has been demonstrated in