Anisotropic Diffusion in Lyotropic Chromonic Liquid Crystal using Fluorescence Recovery After Photobleaching

Kyu Hwan Choi, Jiyong Cheon, Joonwoo Jeong, Sho C. Takatori · 2026

Read Anisotropic Diffusion in Lyotropic Chromonic Liquid Crystal using Fluorescence Recovery After Photobleaching by Kyu Hwan Choi, Jiyong Cheon, Joonwoo Jeong, Sho C. Takatori (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-02147.txt.

Introduction

Kyu Hwan Choi, Jiyong Cheon, Joonwoo Jeong, and Sho Takatori measure how molecules spread in a special liquid in this 2026 study. The liquid forms ordered stacks that guide motion in one direction more than another. They use a light method that bleaches a spot, then watches color return as molecules move in. Two dyes let them compare weak and strong ties to the stacks.

In the ordered phase, both dyes moved faster along the stack direction than across it. A dye bound tight to the stacks slowed in all directions as stacks packed closer. The loose dye sped up along the stacks, hinting at tiny channels. The results show how inner structure steers flow in soft matter.

Catalog record

CREATORKyu Hwan Choi, Jiyong Cheon, Joonwoo Jeong, Sho C. Takatori
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE24519
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.02147

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Anisotropic Diffusion in Lyotropic Chromonic Liquid Crystal using Fluorescence Recovery After Photobleaching Kyu Hwan Choi, Jiyong Cheon, Joonwoo Jeong, Sho C. Takatori Abstract Anisotropic diffusion governs transport in a wide range of soft and biological materials, where microstructure and molecular interactions jointly shape how matter moves. Here, we quantitatively investigate anisotropic molecular transport in lyotropic chromonic liquid crystals (LCLCs) using fluorescence recovery after photobleaching (FRAP). Disodium cromoglycate (DSCG) serves as a model LCLC system, and diffusion is measured across isotropic, nematic, and columnar phases as concentration and temperature are varied. To disentangle the roles of microstructure and molecular interactions, we employ two fluorescent tracers with distinct affinities for the LCLC aggregates: Acridine Orange (AO), which intercalates into DSCG aggregates, and Bodipy, which interacts weakly and remains largely in the aqueous phase. Fourier-space FRAP analysis independently resolves the parallel and perpendicular diffusion coefficients for both dyes relative to the liquid-crystal alignment. In the nematic phase, diffusion becomes anisotropic, with faster transport along the liquid-crystal director. As the DSCG concentration increases, AO dye molecules that are strongly coupled to the aggregates exhibit a slowdown in all directions, reflecting enhanced packing and steric confinement of the LC microstructure. In contrast, weakly interacting Bodipy dye molecules display enhanced transport along the alignment direction as the DSCG concentration increases in the nematic regime, suggesting the emergence of microscopic channels that guide motion, analogous to transport in oriented porous media. These results reveal how the evolving microstructure of LCLCs controls effective diffusion and provide a quantitative framework for understanding and designing anisotropic transport in aligned soft materials. 1 Introduction Macromolecules in biological systems often exhibit anisotropic diffusion due to the order and structure of their surrounding environment. For example, in mammalian cell membranes, diffusion occurs at different rates in-plane and out-of-plane of the lipid bilayer [ 24 , 22 ] . Understanding anisotropic diffusion is crucial for elucidating material transport in such systems, particularly in liquid crystalline environments that mimic biological structures such as membranes and extracellular matrices [ 22 , 5 ] . In lyotropic chromonic liquid crystals (LCLCs), plank-like molecules self-assemble to make rod-like aggregates via face-to-face stacking interactions [ 20 , 16 , 15 , 8 ] . At concentrations above a certain threshold, the aggregates align to form liquid crystalline phases: nematic and columnar phases. In this respect, LCLCs share key physical features with biological materials such as DNA bundles, collagen matrices, and lipid bilayers: they develop microscopic structural alignment that gives rise to direction-dependent transport. In all of these systems, molecular motion is guided by an underlying anisotropic architecture, leading to faster transport along preferred directions and hindered motion across them [ 12 , 14 , 10 ] . Despite their structural and transport relevance to biological systems, how anisotropic diffusion in LCLCs emerges from the interplay between microscopic alignment and molecular-scale interactions remains poorly understood. Previous studies have largely focused on either the self-diffusion of lyotropic liquid crystals or the diffusion of dissolved molecules, without simultaneously characterizing both within the same structured system [ 12 , 13 , 2 , 5 ] . To address this gap, we investigate anisotropic diffusion in lyotropic chromonic liquid crystals using disodium cromoglycate (DSCG) as a model system and fluorescence recovery after photobleaching (FRAP) as a quantitative measurement method. Two fluorescent dyes with distinct strengths of interactions with LCLC aggregates are employed to disentangle the diffusion of DSCG aggregates from that of molecular tracers in the surrounding medium. By systematically varying the DSCG concentration, we examine molecular transport across the isotropic, nematic (N) and columnar (M) phases. FRAP provides a robust measure of bulk effective diffusivity by monitoring the spatiotemporal recovery of fluorescence following localized photobleaching [ 17 , 3 ] . In this study, the interpretation of FRAP measurements is guided by independent characterization of dye–DSCG molecule interactions using UV–Vis spectroscopy [ 26 ] , allowing diffusional behavior to be directly linked to molecular localization within the LCLC system. To quantify transport anisotropy, fluorescence recovery is analyzed in Fourier space, enabling independent extraction of diffusion coefficients parallel and perpendicular to the liquid-crystal alignment [ 5 , 23 , 22 , 25 , 4 , 24 ] . Together, this framework provides a reliable and quantitative link between liquid-crystal microstructure and anisotropic molecular transport in LCLCs. 2 Experimental Methods 2.1 LCLC Preparation Dye-contained DSCG aqueous solution was prepared for FRAP measurements by dissolving DSCG ( \geq 95\% , Sigma-Aldrich) and fluorescent dyes in DI-water ( \geq 18.2\text{\,}\mathrm{M\SIUnitSymbolOhm} ) at DSCG concentrations ranging from 16\text{\,} to 20\text{\,}\mathrm{wt/wt\%} . Two different dyes, Acridine Orange (AO) and Bodipy-NHS, were obtained from Thermo Fisher and added at final concentrations of 3\text{\,}\mathrm{\SIUnitSymbolMicro\textsc{m}} and 50\text{\,}\mathrm{n\textsc{m}} , respectively. These low dye concentrations, 0.05\text{\,} - 3\text{\,}\mathrm{\SIUnitSymbolMicro\textsc{m}} , minimize disturbance to the pristine liquid crystals’ microstructure [ 26 ] . No additional purification steps were performed for any chemicals used in this study. 2.2 Fabrication of Observation Cell The FRAP measurement was conducted using a thin-gap sandwich cell, consisting of a larger coverslip ( 50\text{\,}\mathrm{mm} \times 25\text{\,}\mathrm{mm} ), a smaller coverslip ( 22\text{\,}\mathrm{mm} \times 22\text{\,}\mathrm{mm} ), and a confined LCLC solution. The liquid crystal was aligned by mechanical rubbing, with both glass substrates rubbed in a single direction using abrasive pads (Trizact 3000, 3M). The rubbed glass substrates were sonicated for 30\text{\,}\mathrm{min} in ethanol (Sigma-Aldrich) and DI water, followed by nitrogen drying. The cell thickness, ranging from 5\text{\,} to 7.5\text{\,}\mathrm{\SIUnitSymbolMicro m} , was controlled by adjusting the volume of the liquid crystal solution ( 2.5\text{\,} - 3\text{\,}\mathrm{\SIUnitSymbolMicro L} ) deposited onto the substrate. The coverslip was gently placed to spread the droplet, ensuring the abrasive direction remained aligned. To minimize the water evaporation, the coverslip edges were sealed with epoxy glue (Devcon). To eliminate shear-flow effects and thermal history, the assembled samples were heated to 60\text{\,}\mathrm{\SIUnitSymbolCelsius} for 30\text{\,}\mathrm{min} , during which the DSCG solutions exhibited an isotropic phase. For columnar phase solutions at 20\text{\,}\mathrm{wt/wt\%} DSCG, all components, including glass substrates, pipette tips, and the solution itself, were preheated to 50\text{\,}\mathrm{\SIUnitSymbolCelsius} to facilitate handling of the columnar phase solution by reducing its viscosity. Since water evaporates rapidly at high temperatures, sample preparation was completed within one minute after depositing the solution. LCLC’s phase and homogeneous alignment were verified using a polarized optical microscope (Ti-2 Eclipse, Nikon). The alignment was examined at both 0\text{\,}\mathrm{\SIUnitSymbolDegree} (parallel) and 90\text{\,}\mathrm{\SIUnitSymbolDegree} (crossed) angles between the polarizer and analyzer. 2.3 Fluorescence Recovery After Photobleaching (FRAP) FRAP measurements were performed using an inverted fluorescence microscope equipped with a water-immersion 60 \times objective lens (CFI plan Apo VC, Numerical Aperture 1.2, Nikon). Multi-Line LED Light Source (SpectraX, Lumencor) was used for fluorescence excitation, with wavelengths of 488\text{\,}\mathrm{nm} for Acridine Orange (AO) and Bodipy. The temperature was controlled by the heating stage (H301-Mini, OKOlab). The bleaching spot size was controlled using a circular physical iris with an approximate diameter of 70\text{\,} - 100\text{\,}\mathrm{\SIUnitSymbolMicro m} , as indicated by the white dashed circle in Fig. 1 A. The laser was applied at full power ( 100\text{\,}\mathrm{\%} , 196\text{\,}\mathrm{mW} at the laser head before the optical path) for 60\text{\,}\mathrm{s} to bleach the designated region. Immediately after bleaching, the recovery process was recorded with the laser power reduced to 3\text{\,}\mathrm{\%} , to minimize further photobleaching. Fluorescence

Read the complete text