Scanning Tunneling Microscopy in high vectorial magnetic fields

Jaime Rumeu Ozores, Miguel Águeda Velasco, Edwin Herrera, Pablo García Talavera, Jose D. Bermúdez-Pérez, José A. Moreno, Paula Obladen, Rafael Álvarez Montoya, José Navarrete, Juan Ramón Marijuan, José A. Galvis, Isabel Guillamón, Hermann Suderow · 2026

Read Scanning Tunneling Microscopy in high vectorial magnetic fields by Jaime Rumeu Ozores, Miguel Águeda Velasco, Edwin Herrera, Pablo García Talavera, Jose D. Bermúdez-Pérez, José A. Moreno, Paula Obladen, Rafael Álvarez Montoya, José Navarrete, Juan Ramón Marijuan, José A. Galvis, Isabel Guillamón, Hermann Suderow (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2603-01226.txt.

Introduction

Rumeu and twelve colleagues build a spinning scanning tunneling microscope for studying faces under magnet fields pointing in any aim, not just straight down. Old designs struggle off-axis, so their compact tool fits a 37-mm spin platform, well inside many magnets' space. The setup preserves state-of-the-art noise and accuracy while greatly lifting control over field aim, opening new studies of quantum matter.

Catalog record

CREATORJaime Rumeu Ozores, Miguel Águeda Velasco, Edwin Herrera, Pablo García Talavera, Jose D. Bermúdez-Pérez, José A. Moreno, Paula Obladen, Rafael Álvarez Montoya, José Navarrete, Juan Ramón Marijuan, José A. Galvis, Isabel Guillamón, Hermann Suderow
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36132
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2603.01226

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Scanning Tunneling Microscopy in high vectorial magnetic fields Jaime Rumeu Ozores, Miguel Águeda Velasco, Edwin Herrera, Pablo García Talavera, Jose D. Bermúdez-Pérez, José A. Moreno, Paula Obladen, Rafael Álvarez Montoya, José Navarrete, Juan Ramón Marijuan, José A. Galvis, Isabel Guillamón, Hermann Suderow Abstract The Scanning Tunneling Microscope (STM) is a powerful instrument to study electronic density of states at surfaces down to atomic scale. Many interesting samples require studying variations as a function of the magnetic field, which is most often applied perpendicular to the surface. Conventional STM designs make it challenging to perform measurements when the magnetic field must be applied in other directions. Here we present a new STM setup installed on a rotatable platform. We have designed and built a new STM, which is small enough to allow for full rotation on a space with a diameter of 37 mm, well below the available space within many magnets. We show that the new rotatable STM setup preserves the performance of state-of-the-art STMs in terms of noise and accuracy. Our new approach significantly enhances control over the direction of the applied magnetic field and opens exciting new possibilities to study quantum materials. Introduction The magnetic field is a vector quantity, with magnitude and direction. Consequently, studies of a magnetic property ideally include results obtained for different magnitudes and directions of the magnetic field. For fields of several tens of mT, three-axis Helmholtz coils are widely used Firester 1966 . By contrast, fields in the T range require the use of superconducting solenoids. The available space often consists of a cylindrical volume with a diameter below two inches Fernández-Lomana et al. 2021 ; Larbalestier et al. 2014 . Controlling the direction of the magnetic field requires either (i) combining a long solenoid along a certain direction (z) with split coils located outside the solenoid and oriented in plane (x-y), or (ii) a device that allows modifying the direction of the setup inside a long solenoid. In the first case, the split coils are located far from the measurement setup and the maximum field available in-plane is most often below 3 T Hess, Murray, and Waszczak 1992 ; Hess, Murray, and Waszczak 1994 ; Grigorenko et al. 2001 ; Vlasko-Vlasov et al. 2002 ; Grigorenko et al. 2002 ; Tokunaga et al. 2003 ; Galvis et al. 2013 ; Herrera et al. 2017 ; Curran et al. 2018 ; Galvis et al. 2018 ; Correa et al. 2019 ; Galvis et al. 2015 ; Fridman et al. 2011 ; Fridman et al. 2013 ; Trainer et al. 2017 . The second case is the most frequently adopted solution in measurement setups which are not particularly sensitive to vibrations, including resistivity, magnetization, thermal expansion, specific heat, etc., because it allows reaching the highest magnetic fields. However, such an arrangement, schematically represented in Fig. 1 , has been comparatively less used for Scanning Tunneling Microscopes (STM) 10.1063/1.3663611 ; Trainer et al. 2017 ; 10.1063/5.0294980 . The reason is that a STM usually requires a low vibration environment and is therefore most often mounted on a rigid support without the possibility to change the orientation of the sample, typically allowing to measure only at a fixed orientation of the magnetic field Wu et al. 2025 ; Wang et al. 2023 ; 10.1063/5.0292216 . Furthermore, STMs often require the whole available space inside the solenoid, not allowing for rotation. Here we have miniaturized a STM and installed it on a rotating platform inside a superconducting solenoid. We have achieved controlled variations of the magnitude and direction of the magnetic field, without impairing the usual capabilities of cryogenic STM, i.e. atomic scale control over the position and measurement of the electronic density of states. Figure 1: We schematically show a rotatable Scanning Tunneling Microscope (STM) as a black rectangle. Within the microscope we represent schematically a scanning piezoelement (grey), a tip (orange) and a surface (orange spheres schematically representing atoms). The solenoid is shown in red. The direction of the applied magnetic field is the red arrow. The direction of the STM is varied using a rotatable platform, with the main x and z axis within the surface frame shown in green. The rotating angle is \theta . Figure 2: (a) Schematic of the setup, positioned such that the magnetic field is perpendicular to the surface. A is the rotatable platform. B are copper beams firmly attached to the platform. C are teflon disks which allow to firmly attach the rotatable platform to the copper beams, still allowing for in-situ rotation at cryogenic temperatures. (b) Same schematic as (a) with the platform rotated such that the magnetic field is tilted by 60° from the surface. D is a steel wire. E is a kevlar rope. F is a counteracting spring. (c) Schematic of the vacuum feedthrough actuator. G is a screwed bar. H is a bellow. I is a gearwheel. (d) Schematic drawing of the miniaturized STM. J is the STM base. K is the walker. L is the piezotube. M is a CuBe spring used to fix the walker to the shear piezostack. N is the main head of the miniaturized STM. O are the piezo-stacks for the coarse motion. P are polished alumina. (e) Profile section of the STM base (J) and the sample showing the cleaving process. Top picture shows the sample prepared before being cleaved. Q is a steel wire attached to a second actuator. R is a beam used to cleave the sample. S is the alumina glued on the sample surface. T is the slider. Bottom picture shows the sample at the moment of being cleaved. U is the sample cleaved. V is the cleaved part of the sample. Description of the setup A relevant novel aspect of our work is the development of a rotatable platform, shown in Fig. 2 (a,b). The rotatable platform (A in Fig. 2 (a)) has been manufactured in polyether ether ketone (PEEK) and is attached to copper beams using two screws. The sample is located exactly at the axis of rotation and at the center of the magnet, ensuring exposure of the sample to a spatially uniform magnetic field. There is a flat supporting surface, on which we fix the miniaturized STM using screws and Kevlar ropes. Two reinforced lateral walls are screwed to a copper support. Rotation is possible thanks to two teflon rings located at either side of the assembly (C in Fig. 2 (a)). This configuration allows continuous and dissipation-free rotation with an angular precision better than one degree. A Toshiba THS118 Hall sensor and a CCS carbon thermometer from Temati are located at the bottom of the platform to measure the direction of the magnetic field and the temperature. The rotation is performed at cryogenic temperatures by including a long and thin stainless steel wire (0.1 mm in diameter, D in Fig. 2 (b, c)) which we straighten using a spring and thermalize along the whole length of the cryostat by copper wires soldered to heat sinks. We can pull on the wire using a room temperature bellow actuator, shown in Fig. 2 (c). The wire is soldered to a screw (G in Fig. 2 (c)), which is attached

Read the complete text