Modelling and Analysis of Mechanical and Thermal Response of an Ultrastable, Dual-Axis, Cubic Cavity for Terrestrial and Space Applications
Himanshu Miriyala, Rishabh Pal, Arijit Sharma · 2026
Read Modelling and Analysis of Mechanical and Thermal Response of an Ultrastable, Dual-Axis, Cubic Cavity for Terrestrial and Space Applications by Himanshu Miriyala, Rishabh Pal, Arijit Sharma (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2602-16344.txt.
Introduction
Himanshu Miriyala, Rishabh Pal, and Arijit Sharma model an ultrastable cavity for transportable atomic clocks. Such clocks are the next generation of precision timekeeping, for positioning, navigation, and timing. Their performance depends on ultra-stable lasers held steady by a compact portable cavity. The cubic spacer design suits transport, since its symmetric shape and sturdy mounting limit vibration.
Longer cavities lower the thermal noise floor, but size must be balanced against transportability. The seven and a half centimetre dual-axis cavity beats smaller counterparts on that floor with a reasonable size, weight, and power budget. Its dual-axis design allows multi-wavelength laser stabilization. With the finite element method, the authors test mechanical and thermal stability against geometry, mounting forces, machining flaws, conduction, radiation, and mirror heating in a shielded vacuum chamber. The findings guide robust cavity design for positioning, geodesy, very long baseline interferometry, and deep space missions.
Catalog record
| CREATOR | Himanshu Miriyala, Rishabh Pal, Arijit Sharma |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 47 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2602-16344
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Modelling and Analysis of Mechanical and Thermal Response of an Ultrastable, Dual-Axis, Cubic Cavity for Terrestrial and Space Applications Preprint: APS/123-QED Himanshu Miriyala, Rishabh Pal, Arijit Sharma Abstract Abstract Transportable all-optical atomic clocks represent the next-generation devices for precision time keeping, ushering a new era in encompassing a wide range of PNT (Positioning, Navigation and Timing) applications in the civil and strategic sectors. Their performance relies on ultra-stable, narrow-linewidth lasers, frequency stabilized to a compact portable optical cavity. Among various designs, the cubic spacer-based ultra-stable cavity is particularly well-suited for transportable applications due to its low sensitivity to vibrations, owing to its symmetric geometry and robust mounting structure. While longer cavities offer a lower fundamental thermal noise floor, one needs to strike a balance between transportability and size. In this aspect, the 7.5 cm dual-axis cubic cavity offers a lower fundamental thermal noise floor in comparison to smaller counterparts, while still retaining a reasonable SWaP (Size, Weight and Power) for terrestrial and aerial PNT applications. Its dual-axis design also enables multi-wavelength laser stabilization, making it a promising candidate for future transportable clock applications. This work presents a detailed study of the 7.5 cm dual-axis cubic cavity using FEM (Finite Element Method) to evaluate its mechanical and thermal stability. We analyze the impact of various geometric factors, mounting forces, and machining imperfections, while also modelling thermal effects such as conduction, radiation, and mirror heating within a vacuum chamber and thermally shielded environment. Our findings provide design insights for developing robust dual-axis optical reference cavities, advancing the deployment of portable atomic clocks for next-generation applications in PNT, geodesy, VLBI (Very Long Baseline Interferometry) and deep space missions. I Introduction The pursuit of ever more precise time and frequency standards has transformed modern science and technology, underpinning applications from satellite navigation and telecommunications to tests of the fundamental laws of physics Marlow and Scherer 2021 ; Boldbaatar et al. 2023 ; Vig 1993 ; Mehlstäubler et al. 2018 ; DeMille et al. 2017 ; Safronova et al. 2018 . Optical atomic clocks have emerged as the most accurate and stable timekeepers, with fractional frequency instabilities reaching the 10^{-18} level Bothwell et al. 2019 . Such performance is made possible by interrogating ultranarrow line-width dipole forbidden atomic transitions whose frequencies are stabilized to ultra-stable high-finesse optical resonators. In this context, the frequency stability of the laser and thus of the clock itself is directly determined by the dimension stability of the reference cavity to which it is referenced. The fractional frequency stability of the stabilized laser is directly proportional to the fractional length stability of the cavity. In state-of-the-art laboratory systems, ultra-stable cavities are generally longer operated in vibration-isolated, well temperature-controlled environments, pushing laser instabilities into the low 10^{-16} range over 1 s averaging times Herbers et al. 2022 . However, future applications increasingly demand transportable and even space-qualified clock systems, where such environmental isolation is not always feasible. Transportable optical clocks are being developed for inter-laboratory comparisons, precision time transfer in remote locations, spaceborne fundamental physics missions, and navigation systems that extend beyond the limits of present PNT-based systems Pal et al. 2024 . In these scenarios, the reference cavity must maintain exceptional stability despite exposure to mechanical shocks, varying orientations, and fluctuating thermal conditions. A key challenge in transportable cavities Pal et al. 2024 lies in minimizing acceleration sensitivity without relying solely on external vibration isolation. Among the various approaches to achieving robust frequency references outside controlled laboratory settings, symmetry-based mounting strategies have proven particularly effective in suppressing sensitivity to inertial forces. One of the notable examples is the force insensitive cubic cavity Webster and Gill 2011 ; Wiens and Schiller 2018 , where a cubic spacer is truncated at the vertices and supported at the four vertices in a tetrahedral arrangement. In this geometry, each support force is applied toward the geometric centre of the cube, constraining all translational and rotational degrees of freedom while maintaining force symmetry. This configuration effectively cancels first-order cavity length changes induced by both static preload forces and linear or rotational accelerations. With careful optimization of the vertex truncation depth, such cavities have demonstrated passive acceleration sensitivities as low as 10 {}^{-11}/g Webster and Gill 2011 ; Jiao et al. 2023 making them strong candidates for use in transportable and spaceborne optical clock systems Cole et al. 2024 . Building on this foundation, the dual-axis cubic cavity Hill et al. 2021 ; Stacey et al. 2023 extends the concept by incorporating two orthogonal optical axes within the same cubic spacer. This enables simultaneous stabilization of multiple lasers Wang et al. 2020 for example, a narrow linewidth clock laser and other cooling or trapping lasers within a single mechanically robust platform. Figure 1: Comparative study of 5 cm, 7.5 cm, and 10 cm dual-axis cubic cavities under supportive forces of (a) 50 N (for terrestrial applications) and (b) 500 N (for space applications). Many research groups have demonstrated cubic spacer cavities Webster and Gill 2011 ; Jiao et al. 2023 ; Hill et al. 2021 ; Stacey et al. 2023 ; Wang et al. 2020 ; Cole et al. 2024 , among which the 5 cm cubic cavity (patented by NPL, UK Webster and Gill 2011 ) has become a prominent choice. The compactness and portability of this 5 cm cubic cavity make it particularly suitable for transportable optical clock applications, positioning it as a leading candidate for future space missions Xu et al. 2021 ; Sanjuan et al. 2019 ; Pal et al. 2024 . On the other hand, some groups have demonstrated 10 cm cubic cavities Chen et al. 2020 ; Chen et al. 2023 ; Zhao et al. 2022 , which benefit from a longer cavity length that significantly reduces the thermal noise floor. This makes them a better candidate for transportable systems which require high frequency stability. However, the larger size limits their portability, reducing suitability for transportable or space applications and increasing costs due to greater complexity in thermal management and vibration isolation. Therefore, to strike a balance on size (which determines portability) and noise performance, an analysis comparing different sizes of cubic cavities is essential. We perform a comparative study of 5 cm, 7.5 cm and 10 cm dual-axis cubic cavities, analysing their vibration sensitivity and thermal noise floor. This analysis is conducted for terrestrial applications (with supporting forces of 50 N) and space applications (with supporting forces of 500 N). The sensitivity is determined through the FEA simulation in COMSOL, with the results presented in Figure 1 . The thermal noise floor for the three spacer sizes is calculated analytically following the procedure from Xu et al. 2021 . Both the simulated sensitivities and the analytical noise floor values are summarized in Table 1 . From Table 1 , it is evident that both sensitivity and thermal noise performance improve as the size of the cubic spacer (cavity length) increases. Notably, the performance metrics of the 7.5 cm spacer are much closer to those of the 10 cm spacer than to the 5 cm spacer. This demonstrates that the 7.5 cm cubic spacer provides a practical balance: it delivers performance nearly equivalent to the 10 cm option while remaining more