Comp2Comp: Open-Source Software with FDA-Cleared Artificial Intelligence Algorithms for Computed Tomography Image Analysis

Adrit Rao, Malte Jensen, PhD, Andrea T. Fisher, MD, Louis Blankemeier, PhD, Pauline Berens, MD, Arash Fereydooni, MD, Seth Lirette, PhD, Eren Alkan, BS, Felipe C. Kitamura, MD, PhD, Juan M. Zambrano Chaves, MD, PhD, Eduardo Reis, MD, Arjun Desai, PhD, Marc H. Willis, DO, MMM, FACR, Jason Hom, MD, An · 2026

Read Comp2Comp: Open-Source Software with FDA-Cleared Artificial Intelligence Algorithms for Computed Tomography Image Analysis by Adrit Rao, Malte Jensen, PhD, Andrea T. Fisher, MD, Louis Blankemeier, PhD, Pauline Berens, MD, Arash Fereydooni, MD, Seth Lirette, PhD, Eren Alkan, BS, Felipe C. Kitamura, MD, PhD, Juan M. Zambrano Chaves, MD, PhD, Eduardo Reis, MD, Arjun Desai, PhD, Marc H. Willis, DO, MMM, FACR, Jason Hom, MD, An (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2602-10364.txt.

Description

Scans taken for one purpose often hold extra clues, yet open tools lack strict testing and commercial tools lack openness. A 2026 paper from a large team led by Adrit Rao reports Comp2Comp, an open-source package with two early open, FDA-cleared deep learning pipelines for opportunistic CT analysis. One pipeline segments the abdominal aorta to judge aneurysm size. The other gauges bone density and osteoporosis risk by segmenting vertebral bodies.

The team tested aortic diameters against radiologist measurements on two hundred fifty-eight patient scans from four outside institutions. Bone-density calls were tested against same-day DXA scans on three hundred seventy-one scans. Aortic error averaged about one and a half millimetres; bone-density calls reached about eighty-one percent sensitivity and about seventy-eight percent specificity. The authors judge both accurate enough for clinical use; open sourcing lets hospitals trial the tools before costly pilots.

Catalog record

CREATORAdrit Rao, Malte Jensen, PhD, Andrea T. Fisher, MD, Louis Blankemeier, PhD, Pauline Berens, MD, Arash Fereydooni, MD, Seth Lirette, PhD, Eren Alkan, BS, Felipe C. Kitamura, MD, PhD, Juan M. Zambrano Chaves, MD, PhD, Eduardo Reis, MD, Arjun Desai, PhD, Marc H. Willis, DO, MMM, FACR, Jason Hom, MD, An
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE56 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2602-10364