A Wide Bandwidth Trans-impedance Amplifier for Picosecond-Scale SiPM Characterization in a Wide Temperature Range
and D. Trotta · 2026
Read A Wide Bandwidth Trans-impedance Amplifier for Picosecond-Scale SiPM Characterization in a Wide Temperature Range by and D. Trotta (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-22727.txt.
Introduction
D. Trotta and a co-author describe a wide-band amplifier built to test tiny photon sensors at picosecond scale, across a wide range of cold. Future physics runs may work silicon photomultipliers at very low heat, in harsh radiation, to time single photons sharply. Their 2026 preprint presents a trans-impedance amplifier for that characterization work.
Full maps of sensor traits across heat levels let teams pick the best trade of performance and survival. The amplifier is the enabling tool for those maps. The work is lab hardware, reported for builders. It serves the next wave of detectors.
Catalog record
| CREATOR | and D. Trotta |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 91 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-22727
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Wide Bandwidth Trans-impedance Amplifier for Picosecond-Scale SiPM Characterization in a Wide Temperature Range and D. Trotta Abstract Future high-energy physics experiments using SiPMs as photosensitive elements may require operation at low temperatures (down to 80 K) to measure single photons with high time resolution in a highly radioactive environment. This calls for a complete characterization of these sensors over a wide temperature range to find the best compromise between detector performance and cooling requirements. This paper presents the design of a transimpedance amplifier featuring high gain ( ∼ 7500 V / A \sim 7500\ V/A ), very high speed ( < 500 p s <500\ ps rise time) and low input noise ( ≲ 0.2 p A / H z \lesssim 0.2\ pA/\sqrt{Hz} ), able to faithfully reproduce all the features of SiPM signals with very low noise and time jitter. These features make the amplifier suitable for precise measurements of the time-of-arrival of single-photon signals, as well as gain and recovery time. This article provides a detailed and thorough analysis of the circuit. The network was simulated and measured in two configurations that differ in their open-loop gain and dominant pole frequencies. After selecting the best configuration for our purposes, the amplifier was characterized in detail at ambient temperature and at 80 K. Finally, we evaluated the amplifier using a SiPM operated at low over-voltage. While SiPMs are typically characterized at high over-voltage to enhance gain and minimize timing jitter, testing at low over-voltage allowed us to assess the amplifier’s performance under more challenging and realistic conditions for single-photon timing. 1 Introduction Recent developments in physics show a growing interest in solid-state single-photon detectors. They are used in calorimeters, trackers, ring-imaging Cherenkov detectors, time-of-flight systems and others. The most common are Silicon PhotoMultipliers (SiPMs). These sensors are sensitive to single photons, are rather compact, immune to magnetic fields and need relatively low voltage bias, all characteristics that make them attractive when evaluating the requirements of the detector and the extreme conditions in which these sensors would be used. However, the major downside of using these sensors in high-energy physics experiments is that radiation can hinder their single-photon sensitivity [ 1 ] . As with many solid-state sensors, they are sensitive to displacement damage caused by hadron fluence, conventionally rescaled to the effects of equivalent 1-MeV neutrons. The primary effect in SiPMs is an increase in the rate of spurious single-photon signals, or dark count rate (DCR), which is often mitigated by lowering the temperature. At high fluences ( 10^{12}\sim 10^{13}\ cm^{-2}\ 1-MeV-equivalent ), the cooling requirements can range down to cryogenic temperatures [ 2 ] . For this reason, to assess the application of SiPMs in all scenarios, these devices need to be characterized at different temperatures to find the best compromise between operating temperature and DCR. For best results with timing measurements, the readout electronics needs to be placed as close as possible to the SiPMs to preserve signal integrity. Therefore, here lies the necessity to design an amplifier that can work at a wide temperature range, between 300 K (ambient temperature) and cryogenic temperatures. This amplifier must be suitable for SiPM characterization, hence a wide bandwidth ( \sim GHz ) is required to preserve the SiPM signal shape and enable precise timing measurements, especially when the SiPM is operated at low over-voltage. In this paper, we first describe the circuit schematic and study the amplifier stability. Then we provide an overview of two different amplifier configurations. The two configurations are simulated and compared with real-world measurements at ambient temperature (300 K). After evaluating the pros and cons of the two solutions, we study the most promising one in more detail and measure its behavior at both ambient and cryogenic temperatures (liquid nitrogen). In the final section, we demonstrate the amplifier’s performance in detecting single-photon signals from a SiPM at the two extremes of the temperature range. 2 Circuit analysis Two different configurations are analyzed: the “Opamp Dominant Pole” (ODP) and the “Transistor Dominant Pole” (TDP). The schematic, shown in figure 1 , is the same for the two configurations. The main difference between them lies in the operating mode of the Current Feedback Operational Amplifier (CFOA): in the ODP configuration, a high-value local feedback resistor R_{2} is used, whereas in the TDP configuration a low-value R_{2} is employed, shifting the dominant pole of the CFOA to a higher frequency. Moreover, each configuration employs different passive components and CFOA models in order to optimize speed. The two amplifiers are very similar, so we can make a general explanation of how the circuit works, and later elaborate on the two separately. I_{in} R_{s2} 50\ \Omega SiPM R_{HV} V_{HV} R_{s1} C_{HV} C_{t} 1\text{\,}\mathrm{p}\mathrm{F} R_{t} 50\ \Omega LEMO Test signal HBT V_{c} R_{c} V_{POS} + \vphantom{+}- CFOA R_{d} C_{d} C_{x} C_{p} R_{1} C_{1} R_{2} V_{CC} V_{EE} V_{out} R_{out} C_{out} 50\ \Omega LEMO R_{osc} V_{osc} R_{f} V_{be} C_{p_{R_{f}}} R_{b} C_{b} Input signals \mathbf{C_{c}} \mathbf{Z_{b}} \mathbf{Z_{f}} Figure 1 : Schematic of the amplifier circuit. The gray components represent the parasitic capacitances. The amplifier is a two-stage transimpedance amplifier. Two signal sources are connected to its input: the input signal can come from the SiPM through a resistor R_{s} , where R_{s}=R_{s1}+R_{s2} , or it can be a test signal coupled to the input through C_{t}=1\ pF . Regarding the test signal, a step voltage is typically used to inject a current impulse. The passive elements C_{t} and R_{t}=50\ \Omega are both laid out in the closest proximity to the amplifier input to avoid the formation of reflections in the signal path, and to minimize parasitic inductances. In the other case, the SiPM power supply ( V_{HV} ) is low-pass filtered with R_{HV}=10\ k\Omega and the series of C_{HV}=100\ nF and R_{s1} . The resistors R_{s1} and R_{s2} also have two other purposes: they are used as termination for the SiPM signals and for the amplifier loop-gain compensation. To reduce front-end effects that alter the SiPM pulse shape, R_{s1} and R_{s2} are replaced with shorts whenever feasible. To quantify the impact of these resistors on the SiPM signal frequency content, we can analyze the structure of the SiPM more closely. Figure 2 shows the model of the SiPM with one fired cell (photon hitting one cell of the sensor and generating a signal) [ 3 ] . The firing of a cell can be modeled by a \delta(t) -like current impulse that, in the Laplace transform domain, results i_{1cell}(s)=Q_{0} . When a single cell fires, the current signal i_{in} reaching the amplifier input is well approximated by: i_{in}(s)\simeq Q_{0}\frac{1+sC_{q}R_{q}}{\left[1+sC_{q}R_{q}\frac{(Z_{in}+R_{s})}{(Z_{in}+R_{s})+R_{q}/(N+1)}\right]\left[1+s(C_{det}(N+1)(Z_{in}+R_{s})+(C_{det}+C_{q})R_{q})\right]} (2.1) where Z_{in} is the amplifier input impedance and the bias filtering capacitor C_{HV} is assumed a short circuit. Equation ( 2.1 ) exhibits two distinct negative real poles, responsible for the SiPM signal roll-off in the time domain. Both poles depend on R_{s} . An increase in R_{s} , leads to a corresponding increase in the SiPM signal time constants. For this reason, R_{s} should be kept as small as possible. Following the same reasoning, a higher amplifier input impedance Z_{in} should also be avoided. However, there might be some cases where C_{g} is big enough or