ReactEMG Stroke: Healthy-to-Stroke Few-shot Adaptation for sEMG-Based Intent Detection

Runsheng Wang, Katelyn Lee, Xinyue Zhu, Lauren Winterbottom, Dawn M. Nilsen, Joel Stein, Matei Ciocarlie · 2026

Read ReactEMG Stroke: Healthy-to-Stroke Few-shot Adaptation for sEMG-Based Intent Detection by Runsheng Wang, Katelyn Lee, Xinyue Zhu, Lauren Winterbottom, Dawn M. Nilsen, Joel Stein, Matei Ciocarlie (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-22090.txt.

Introduction

Runsheng Wang and co-authors help stroke survivors' hands obey them again. Surface electromyography reads muscle signals from the skin, a promising control signal for assist-as-needed hand rehabilitation. Detecting intent from weakened, stroke-affected muscles is hard, though: calibration is long and subject-specific, and detection stays brittle.

Their 2026 preprint, ReactEMG Stroke, adapts intent detection from healthy users to stroke patients with only a few examples from the patient. Few-shot adaptation could make rehabilitation devices practical in clinics, where long calibration sessions are unaffordable. A device that reads intent reliably can assist movement at the right moment, which is how retraining a hand is thought to work.

Catalog record

CREATORRunsheng Wang, Katelyn Lee, Xinyue Zhu, Lauren Winterbottom, Dawn M. Nilsen, Joel Stein, Matei Ciocarlie
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE25 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-22090

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

ReactEMG Stroke: Healthy-to-Stroke Few-shot Adaptation for sEMG-Based Intent Detection Runsheng Wang, Katelyn Lee, Xinyue Zhu, Lauren Winterbottom, Dawn M. Nilsen, Joel Stein, Matei Ciocarlie Abstract Surface electromyography (sEMG) is a promising control signal for assist-as-needed hand rehabilitation after stroke, but detecting intent from paretic muscles often requires lengthy, subject-specific calibration and remains brittle to variability. We propose a healthy-to-stroke adaptation pipeline that initializes an intent detector from a model pretrained on large-scale able-bodied sEMG, then fine-tunes it for each stroke participant using only a small amount of subject-specific data. Using a newly collected dataset from three individuals with chronic stroke, we compare adaptation strategies (head-only tuning, parameter-efficient LoRA adapters, and full end-to-end fine-tuning) and evaluate on held-out test sets that include realistic distribution shifts such as within-session drift, posture changes, and armband repositioning. Across conditions, healthy-pretrained adaptation consistently improves stroke intent detection relative to both zero-shot transfer and stroke-only training under the same data budget; the best adaptation methods improve average transition accuracy from 0.42 to 0.61 and raw accuracy from 0.69 to 0.78. These results suggest that transferring a reusable healthy-domain EMG representation can reduce calibration burden while improving robustness for real-time post-stroke intent detection. I INTRODUCTION Robot-assisted wearable devices can provide task-specific, high-dose training to support post-stroke upper-limb recovery. In hand rehabilitation, these systems often assist finger extension (hand opening), allowing patients to repeatedly practice grasp-and-release movements [ 12 ] . To better translate repetitions into recovery, assistance should engage the patient’s own neuromuscular drive rather than delivering purely passive motion [ 5 , 7 , 16 ] . Many devices therefore perform intent detection, using biosignals to infer when a patient is attempting a movement. In this context, models that decode movement intent from surface electromyography (sEMG) are particularly attractive because sEMG is non-invasive, reflects muscle activation, and supports assist-as-needed control that builds on voluntary effort. However, recent reviews emphasize that sEMG-based intent detection models for stroke survivors still rely on lengthy, subject-specific calibration and remain a key bottleneck for practical deployment [ 4 , 10 ] . Robust sEMG-based intent detection from paretic muscles typically requires such calibration because the underlying signals differ substantially from those of able-bodied users. Weakness and reduced voluntary drive produce small, noisy signals, while spasticity and abnormal synergies induce co-contraction (e.g., flexor activation during attempted hand opening) [ 2 ] . As a result, each patient often requires large amounts of EMG data paired with ground-truth intent labels to obtain a usable model, and these models can be fragile. Performance may degrade with small changes in posture or sensor placement, and learned models risk overfitting to session-specific patterns that may not generalize reliably even to the same individual. To address this bottleneck, we propose healthy-to-stroke few-shot adaptation for sEMG intent detection: we initialize the intent detector from a model pretrained on large-scale able-bodied sEMG and then fine-tune it for each stroke survivor using only a small dataset. This reframes training as adapting a shared, reusable EMG representation to a new stroke participant, with most representation learning occurring in the healthy domain. Most prior work addresses this bottleneck with few-shot or adaptive learning strategies in the stroke domain. Sarwat et al. apply a prototypical network that learns an embedding space and performs one-shot adaptation with distance-based classification [ 13 ] . La Rotta et al. propose MetaEMG, a meta-learning framework trained on stroke EMG across subjects and sessions to rapidly adapt a downstream model from a small subject-specific training set [ 9 ] . Xu et al. introduce ChatEMG, a generative model that augments small per-subject datasets with synthetic samples to improve classifier performance [ 17 ] . In parallel, several studies leverage data sources beyond the stroke domain by constructing mixed healthy-stroke datasets. Cesqui et al. and Montecinos et al. perform a design-space search using healthy EMG, then apply the resulting healthy-derived configurations when training a model on stroke data [ 3 , 11 ] . Anastasiev et al. train a model on bilateral EMG from both the paretic and non-paretic limbs of stroke patients in a single stage, using the non-paretic limb as an additional subject-specific data source [ 1 ] . Taken together, these stroke-only and mixed-domain methods show that careful learning strategies can improve data efficiency. Yet they share a core limitation: the stroke model is still initialized from scratch and trained on small, stroke-only datasets. Even when healthy or non-paretic EMG is incorporated, it is typically used either to tune model configurations or as an auxiliary source for joint training, rather than to pretrain a reusable representation that can be transferred to new stroke users. Meanwhile, large sEMG datasets and foundation-style models for able-bodied users have emerged, demonstrating strong cross-subject performance and zero-shot generalization [ 15 , 8 ] . Since these models capture structures in EMG signals across many healthy users, they provide a natural source of transferable representations for the data-limited stroke setting. A direct way to exploit this structure is to initialize stroke intent detection from a healthy-pretrained model and adapt it via fine-tuning. Motivated by this gap, we introduce ReactEMG Stroke, a healthy-to-stroke fine-tuning framework for sEMG intent detection. We treat ReactEMG, a model pretrained on able-bodied subjects, as an EMG foundation model and study its adaptation to stroke subjects in the context of intent detection for controlling a robotic hand orthosis. We ask how much per-subject labeled stroke data is needed when starting from a healthy model, and how different fine-tuning strategies behave under the same data budget. Our contributions are as follows: • Healthy-to-stroke transfer learning for intent detection. To the best of our knowledge, we are the first to adapt a healthy-pretrained EMG model to stroke intent detection. We fine-tune a pretrained healthy-domain model and show that it improves intent detection performance over stroke-only training across both in-domain and distribution-shifted test sets. • Comparison of fine-tuning strategies. Under identical data budgets, training objectives, and model selection procedures, we compare stroke-only training from scratch against head-only tuning, parameter-efficient low-rank adapters, and full-model fine-tuning. We evaluate accuracy and real-time control metrics across participants to distill practical guidance on how best to adapt a healthy model under tight budgets. II METHOD Our goal is to infer a stroke participant’s intended hand gesture from forearm EMG signals recorded during attempted movement and use it to control a robotic hand orthosis that assists the corresponding gesture. We capture 8 -channel EMG signals (Myo armband, Thalmic Labs), sampled at 200 Hz, and train a model to predict the current intent from a predefined set of K action classes (e.g., open hand , close hand , relax ) using short windows of muscle activity. Let x=\{x_{1},x_{2},\dots,x_{T}\}\in\mathbb{R}^{T\times C} represent a window of length T of multichannel EMG time series sampled from C sensors. Given x , the model learns a mapping f:\mathbb{R}^{T\times C}\rightarrow\mathbb{R}^{K} and outputs an intent likelihood vector y\in\mathbb{R}^{K} . In online use, f is queried repeatedly on a sliding window over the incoming EMG stream to provide control signals for an orthosis. In this study, we use the MyHand orthosis [ 12 ] . We study healthy-to-stroke transfer learning for sEMG-based intent detection under data constraints. For each stroke participant, we start from a model pretrained

Read the complete text