Darren Dahunsi 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Randy Palamar 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Tyler Henry 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Mohammad Rahim Sobhani 1,2 {}^{\textbf{1,2}}, \IEEEmembership Student Member, IEEE, Nega · 2026
Read Orthogonal Plane-Wave Transmit-Receive Isotropic-Focusing Micro-Ultrasound (OPTIMUS) with Bias-Switchable Row-Column Arrays by Darren Dahunsi 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Randy Palamar 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Tyler Henry 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Mohammad Rahim Sobhani 1,2 {}^{\textbf{1,2}}, \IEEEmembership Student Member, IEEE, Nega (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-20066.txt.
Introduction
Darren Dahunsi and colleagues present a new ultrasound imaging method for seeing inside the body in three dimensions. High-quality volumetric imaging is hard with today's probes. Matrix probes have limited fields of view and element counts. Row-column arrays offer an alternative geometry but bring their own compromises.
Their method, OPTIMUS, transmits and receives orthogonal plane waves with isotropic focusing. It uses row-column arrays whose bias can be switched to steer the imaging. The goal is structural volume images with wide coverage and fine detail. Better bedside volumetric imaging would aid diagnosis without moving patients to large scanners. The work pushes array design and beamforming together.
Catalog record
| CREATOR | Darren Dahunsi 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Randy Palamar 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Tyler Henry 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Mohammad Rahim Sobhani 1,2 {}^{\textbf{1,2}}, \IEEEmembership Student Member, IEEE, Nega |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 19 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-20066
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Orthogonal Plane-Wave Transmit-Receive Isotropic-Focusing Micro-Ultrasound (OPTIMUS) with Bias-Switchable Row-Column Arrays Darren Dahunsi 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Randy Palamar 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Tyler Henry 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Mohammad Rahim Sobhani 1,2 {}^{\textbf{1,2}}, \IEEEmembership Student Member, IEEE, Negar Majidi 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Joy Wang 1 {}^{\textbf{1}}, \IEEEmembership Student Member, IEEE, Afshin Kashani Ilkhechi 1,2 {}^{\textbf{1,2}}, \IEEEmembership Student Member, IEEE, and Roger Zemp 1,2 {}^{\textbf{1,2}}, \IEEEmembership Member, IEEE Abstract High quality structural volumetric imaging is a challenging goal to achieve with modern ultrasound transducers. Matrix probes have limited fields of view and element counts, whereas row-column arrays (RCAs) provide insufficient focusing. In contrast, Top-Orthogonal-to-Bottom-Electrode (TOBE) arrays, also known as bias-switchable RCAs can enable isotropic focusing on par with ideal matrix probes, with a field of view surpassing conventional RCAs. Orthogonal Plane-Wave Transmit-Receive Isotropic-Focusing Micro-Ultrasound (OPTIMUS) is a novel imaging scheme that can use TOBE arrays to achieve nearly isotropic focusing throughout an expansive volume. This approach extends upon a similar volumetric imaging scheme, Hadamard Encoded Row Column Ultrasonic Expansive Scanning (HERCULES), that is even able to image beyond the shadow of the aperture, much like typical 2D matrix probes. We simulate a grid of scatterers to evaluate how the resolution varies across the volume, and validate these simulations experimentally using a commercial calibration phantom. Experimental measurements were done with a custom fabricated TOBE array, custom biasing electronics, and a research ultrasound system. Finally we performed ex-vivo imaging to assess our ability to discern structural tissue information. {IEEEkeywords} 3D imaging, hadamard encoded readout (HERO), hadamard encoded row column ultrasonic expansive scanning (HERCULES), orthogonal plane-wave transmit-receive isotropic-focusing micro-ultrasound (OPTIMUS), row-column arrays, top-orthogonal-to-bottom electrode (TOBE) arrays, † † corresponding: Corresponding author: Darren Dahunsi (email: [email protected]). † † note: RJZ and MRS are directors and shareholders of CliniSonix Inc., which provided partial support for this work. RJZ is a founder and director of OptoBiomeDx Inc., which, however, did not support this work. RJZ is also a founder and shareholder of IllumiSonics Inc.,which, however, did not support this work. We gratefully acknowledge funding from the National Institutes of Health (1R21HL161626-01 and EITTSCA R21EYO33078), Alberta Innovates (AICE 202102269, CASBE 212200391 and LevMax 232403439), MITACS (IT46044 and IT41795), CliniSonix Inc., NSERC (2025-05274) and a NSERC CGS-D to DD (588860 - 2024), the Alberta Cancer Foundation and the Mary Johnston Family Melanoma Grant (ACF JFMRP 27587), the Government of Alberta Cancer Research for Screening and Prevention Fund (CRSPPF 017061), an Innovation Catalyst Grant to MRS, INOVAIT (2023-6359), and an IBET Momentum Fellowship to DD. We are grateful to the nanoFAB staff at the University of Alberta for facilitating array fabrication. 1 Introduction Figure 1 : Summary of the OPTIMUS imaging scheme for an arbitrarily sized array of N rows and N columns with N \times M transmit events. In a) we use the rows of a Hadamard matrix to determine the biasing and transmit polarities that are applied on the rows as shown in b), with each column of the matrix corresponding to a different row of the array. c) shows a render of the effective layout of the element electrodes on the transducer, and an effective transmit waveform. In d) we can see the effective bias pattern between each transmit event. For a set of N transmits the transmitted waveform will not change, but the received waveform will, and decoding will result in the receive aperture shown in e). f) We will repeat those N transmits for M different plane-wave angles and obtain the effective imaging aperture shown in g). \IEEEPARstart Volumetric, ultrasound imaging is an area of growing interest as transducer and computational capabilities increase and realtime volumetric imaging becomes more feasible. Newer transducer architectures such as matrix probes and row column arrays have potential to enable clinical applications that require accurate 3-dimensional views of physiology. Volumetric views also better enable certain advanced imaging modes like elastography and blood flow imaging. Furthermore, 3D imaging may mitigate operator dependence. [ 22 , 25 , 1 , 26 , 5 , 10 , 14 ] Table 1 : Imaging Parameters a) Transducer Parameters Value 2D array size 128 + 128 Transmit Count 128 Pitch 250 \mu m Kerf 30 \mu m Center frequency 6.25 MHz b) Simulation Parameters Value Number of excitation cycles 1 Speed of Sound 1540 m/s Sampling frequency 50 MHz c) Experimental Parameters Value Chirp Length 20e-6 \mu s Chirp Bandwidth 4 - 8 MHz Speed of Sound 1452 m/s Sampling frequency 16.6 MHz d) Imaging Parameters Value Transmit Count (OPTIMUS) 1152 Transmit Count (HERCULES, VLS, TPW) 128 Angle Count (OPTIMUS) 9 Maximum Angle (OPTIMUS) \pm 10^{\circ} Maximum Angle (TPW) \pm 10^{\circ} Fully wired matrix probes have been proposed to achieve volumetric images, but the B-scan image quality is often inferior to clinical linear arrays which have a wide footprint and thus a low f-number. Scaling matrix probes up to similar footprints as these linear arrays is non-trivial. As the channel count of a 2D array increases quadratically, existing matrix probes are limited to small footprints, with 32 \times 32 matrix probes being the largest commercial probes currently available. X-Matrix probes with microbeamformers require non-ideal beamforming approximations and wide beam transmits which negatively impact image quality. [ 22 , 24 , 12 , 27 ] Conversely, Row Column Arrays (RCAs) are able to have large footprints and large element counts, which promise high numerical apertures. However, because they are effectively two orthogonal linear arrays, they suffer from a lack of two-way focusing and are also constrained to imaging directly below the shadow of the aperture. There are previous RCA imaging schemes that use this architecture to perform volumetric imaging. Virtual line-source imaging (VLS) uses an array of virtual line sources as the transmit aperture, while Tilted Plane-Wave (TPW) imaging uses a series of tilted plane-waves [ 2 , 11 , 16 ] . Combined with using the orthogonal array as a receive aperture, RCAs can only perform one-way cylindrical focusing on transmit or receive, but not both. This is unlike an ideal fully-wired matrix probe that can perform two-way spherical focusing, and this limitation causes reduced image quality. Many modern volumetric imaging setups attempt to leverage the principles of ultrafast ultrasound imaging. Some of the primary benefits of ultrafast imaging are the decoupling of volume acquisition rate from volume resolution and the increased temporal coherence across the volume. On the other hand, insonifying the entire imaged region simultaneously reduces contrast [ 18 , 8 , 23 ] . Extended transmits like chirp excitations can be used to mitigate these types of issues, but in turn potentially introduce problems like a high mechanical index and probe heating [ 17 , 3 , 19 ] . Thankfully, the increased surface area of large specialized RCA arrays can mitigate these issues. Electrostrictive top-orthogonal-to-bottom-electrode (TOBE) arrays are bias-sensitive RCAs that allow new capabilities beyond what conventional piezoelectric RCAs can enable. These electrostrictives are not inherently piezoelectric until a bias voltage is applied. This bias-sensitivity means that we can selectively enable sections of a transducer array. When this property is applied to a row-column array this allows us to manipulate or encode the effective aperture of the transducer on transmit or receive.